Current Sensors
| Photo | Mfr. Part # | Availability | Quantity | Datasheet | Series | Package/Case | Packaging | Product Status | For Measuring | Sensor Type | Current - Sensing | Number of Channels | Output | Sensitivity | Frequency | Linearity | Accuracy | Voltage - Supply | Response Time | Current - Supply (Max) | Operating Temperature | Grade | Qualification | Polarization | Mounting Type | Supplier Device Package |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
HXS 10-NP/SP3SENSORS |
0 |
|
|
HXS | Module | Bulk | Not For New Designs | AC/DC | Hall Effect | 10A, 20A (Selectable) | 1 | Analog Voltage | 625mV/A | DC ~ 50kHz | ±0.5% | ±1% | 5V | 3µs | 19mA | -40°C ~ 85°C | - | - | Unidirectional | Through Hole | - |
|
|
F01P006S05LSENSOR |
0 |
|
|
F01P | Module | Tray | Active | AC/DC | Flux Gate, Closed Loop | 6A | 1 | Ratiometric, Voltage | 104.2mV/A | 300kHz | ±1% | ±2.5% | 5V | 0.3µs | 25mA | -40°C ~ 105°C | - | - | Bidirectional | Through Hole | - |
|
|
F03P006S05DSENSOR |
0 |
|
|
F03P | Module | Tray | Active | AC | Flux Gate, Closed Loop | 6A | 1 | Ratiometric, Voltage | 104.2mV/A | 300kHz | ±0.1% | - | 4.75V ~ 5.25V | 0.3µs | 25mA | -40°C ~ 105°C | - | - | Bidirectional | Through Hole | - |
|
|
F02P006S05LSENSOR |
0 |
|
|
F02P | Module | Tray | Active | AC | Flux Gate, Closed Loop | 6A | 1 | Ratiometric, Voltage | 104.2mV/A | 300kHz | ±1% | ±1.7% | 5V | 0.3µs | 25mA | -40°C ~ 105°C | - | - | Bidirectional | Through Hole | - |
|
L31S050S05FSSENSOR CURRENT HALL 50A AC/DC |
0 |
|
|
L31SXXXS05S | Module, Single Pass Through | Bulk | Active | AC/DC | Hall Effect, Open Loop | 50A | 1 | Ratiometric, Voltage | - | DC ~ 100kHz | ±0.5% | - | 5V | 5µs | 15mA | -40°C ~ 85°C | - | - | Bidirectional | Chassis Mount | - |
|
L03S400D15WJCURRENT SENSOR (400A; 15V) |
0 |
|
|
L03S | Module, Single Pass Through | Bulk | Active | AC/DC | Hall Effect, Closed Loop | 400A | 1 | Ratiometric, Voltage | - | - | ±1% | - | ±12V ~ 15V | 10µs | 20mA | -10°C ~ 80°C | - | - | Bidirectional | Chassis Mount | - |
|
|
S22P015S05SENSOR CURRENT HALL 15A AC/DC |
0 |
|
|
- | Module | Bulk | Obsolete | AC/DC | Hall Effect, Closed Loop | 15A | 1 | Ratiometric, Voltage | - | DC ~ 100kHz | ±0.2% | - | 5V | 1µs | 12.5mA | -10°C ~ 85°C | - | - | Bidirectional | Through Hole | - |
|
CSLH3A9SENSOR CURRENT HALL 9A AC/DC |
0 |
|
|
CSLH | Module, Single Pass Through | Bulk | Obsolete | AC/DC | Hall Effect, Open Loop | 9A | 1 | Ratiometric, Voltage | 282mV/N | - | - | - | 4.5V ~ 10.5V | 3µs | 30mA | -25°C ~ 85°C | - | - | Bidirectional | Through Hole | - |
|
L03S300D15WMSENSOR |
0 |
|
|
L03S | Module | Tray | Obsolete | AC/DC | Hall Effect, Open Loop | 300A | 1 | Ratiometric, Voltage | - | DC ~ 100kHz | ±1% | - | 15V | 10µs | 20mA | -10°C ~ 80°C | - | - | Bidirectional | Chassis Mount | - |
|
S23P50/100D15M2CURRENT SENSOR (50A/100A; 15V) |
0 |
|
|
S23P M2 | Module | Tray | Active | AC/DC | Hall Effect, Closed Loop | 50A, 100A | 1 | Ratiometric, Current | - | - | ±0.15% | ±0.25% | ±12V ~ 15V | 500ns | 16mA | -40°C ~ 85°C | - | - | Unidirectional | Through Hole | - |
|
|
S22P025S05SENSOR CURRENT HALL 25A AC/DC |
0 |
|
|
- | Module | Bulk | Obsolete | AC/DC | Hall Effect, Closed Loop | 25A | 1 | Ratiometric, Voltage | - | DC ~ 100kHz | ±0.2% | - | 5V | 1µs | 12.5mA | -10°C ~ 85°C | - | - | Bidirectional | Through Hole | - |
|
L18P005D15SENSOR CURRENT HALL 5A AC/DC |
1 |
|
|
- | Module | Bulk | Obsolete | AC/DC | Hall Effect, Open Loop | 5A | 1 | Ratiometric, Voltage | - | DC ~ 100kHz | ±1% | - | ±15V | 5µs | 15mA | -30°C ~ 80°C | - | - | Bidirectional | Through Hole | - |
|
L31S100S05FSSENSOR CURRENT HALL 100A AC/DC |
0 |
|
|
L31SXXXS05S | Module, Single Pass Through | Bulk | Active | AC/DC | Hall Effect, Open Loop | 100A | 1 | Ratiometric, Voltage | - | DC ~ 100kHz | ±0.5% | - | 5V | 5µs | 15mA | -40°C ~ 85°C | - | - | Bidirectional | Chassis Mount | - |
|
T60404N4647X161CURRENT SENSOR, 50A, PRI OPEN, 5 |
0 |
|
|
- | Module, Single Pass Through | Box | Active | AC/DC | Closed Loop | 50A | 1 | Ratiometric, Voltage | - | DC ~ 100kHz | ±0.1% | ±1% | 4.75V ~ 5.25V | 1µs | 16mA | -40°C ~ 85°C | - | - | Unidirectional | Through Hole | - |
|
CASR 25-NP/SP3TRANSDUCER |
0 |
|
|
CASR | Module | Bulk | Active | AC/DC | Closed Loop | 25A | 1 | Voltage | 25mV/A | DC ~ 300kHz | ±0.1% | ±0.8% | 4.75V ~ 5.25V | 300ns | - | -40°C ~ 105°C | - | - | Unidirectional | Through Hole | - |
|
CASR 15-NP/SP3TRANSDUCER |
0 |
|
|
CASR | Module | Bulk | Active | AC/DC | Closed Loop | 15A | 1 | Voltage | 41.67mV/A | DC ~ 300kHz | ±0.1% | ±0.8% | 4.75V ~ 5.25V | 300ns | - | -40°C ~ 105°C | - | - | Unidirectional | Through Hole | - |
|
L03S500D15WJCURRENT SENSOR (500A; 15V) |
0 |
|
|
L03S | Module, Single Pass Through | Bulk | Active | AC/DC | Hall Effect, Closed Loop | 500A | 1 | Ratiometric, Voltage | - | - | ±1% | - | ±12V ~ 15V | 10µs | 20mA | -10°C ~ 80°C | - | - | Bidirectional | Chassis Mount | - |
|
HLSR 16-PW-010TRANSDUCER |
0 |
|
|
HLSR | Module | Bulk | Active | AC/DC | Open Loop | 16A | 1 | Voltage | - | - | ±0.5% | - | 4.5V ~ 5.5V | - | 31mA | -40°C ~ 105°C | - | - | Bidirectional | Through Hole | - |
|
HLSR 32-PW-010TRANSDUCER |
0 |
|
|
HLSR | Module | Bulk | Active | AC/DC | Open Loop | 16A | 1 | Voltage | - | - | ±0.5% | - | 4.5V ~ 5.5V | - | 31mA | -40°C ~ 105°C | - | - | Bidirectional | Through Hole | - |
|
HLSR 50-PW-010TRANSDUCER |
0 |
|
|
HLSR | Module | Bulk | Active | AC/DC | Open Loop | 16A | 1 | Voltage | - | - | ±0.5% | - | 4.5V ~ 5.5V | - | 31mA | -40°C ~ 105°C | - | - | Bidirectional | Through Hole | - |
Category Overview
Current Sensors Products & Selection Guide
Current Sensors are widely used in industrial automation, automotive electronics, communication equipment, consumer electronics, new energy systems, and many other electronic applications. We offer products from multiple manufacturers, packages, and specifications to help engineers and buyers compare and source suitable components.
Use the manufacturer, key specification, availability, and Datasheet filters to narrow down the right Current Sensors. If the exact part is not listed, submit an inquiry and our team can help check stock, lead time, and suitable alternatives.
FAQ
How do I choose the right Current Sensors?
Start with the required electrical specifications, package, operating temperature, application conditions, and manufacturer preference, then compare availability and lead time.
Can I order based on the stock shown on this page?
Inventory can change with supply conditions. For project or volume requirements, please submit an inquiry so current stock, pricing, and lead time can be confirmed.
What if the exact part number I need is not listed?
Send us the part number and required quantity. We can help source hard-to-find parts and suggest suitable alternatives based on key specifications.
Do you provide Datasheets and technical documents?
Yes. Use the Datasheet links in the product list to view available technical documents. If a document is unavailable, contact us and we can help check it.