Current Sensors
| Photo | Mfr. Part # | Availability | Quantity | Datasheet | Series | Package/Case | Packaging | Product Status | For Measuring | Sensor Type | Current - Sensing | Number of Channels | Output | Sensitivity | Frequency | Linearity | Accuracy | Voltage - Supply | Response Time | Current - Supply (Max) | Operating Temperature | Grade | Qualification | Polarization | Mounting Type | Supplier Device Package |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
HLSR 10-P/SP1TRANSDUCER |
0 |
|
|
HLSR | Module | Bulk | Active | AC/DC | Hall Effect, Open Loop | 10A | 1 | Voltage | 40mV/A | DC ~ 240kHz | ±0.5% | ±1% | 4.5V ~ 5.5V | 3.5µs | 25mA | -40°C ~ 105°C | - | - | Unidirectional | Through Hole | - |
|
L18P050S05RSENSOR CURRENT HALL 50A AC/DC |
0 |
|
|
L18PXXXS05 | Module | Bulk | Active | AC/DC | Hall Effect, Open Loop | 50A | 1 | Ratiometric, Voltage | - | DC ~ 100kHz | ±1% | - | 5V | 5µs | 15mA | -30°C ~ 80°C | - | - | Bidirectional | Through Hole | - |
|
ACS37032LLZATR-020B3CURRENT SENSOR 5 MHZ |
0 |
|
|
- | 8-SOIC (0.154", 3.90mm Width), 6 Leads | Tape & Reel (TR) | Active | AC/DC | Hall Effect | 20A | 1 | Analog Voltage | 66mV/A | DC ~ 5MHz | - | - | 3V ~ 3.6V | 40ns | 30mA | -40°C ~ 150°C | - | - | Bidirectional | Surface Mount | 6-SOIC |
|
ACS37030LLZATR-020B3CURRENT SENSOR 5 MHZ |
0 |
|
|
- | 8-SOIC (0.154", 3.90mm Width), 6 Leads | Tape & Reel (TR) | Active | AC/DC | Hall Effect | 20A | 1 | Analog Voltage | 66mV/A | DC ~ 5MHz | - | - | 3V ~ 3.6V | 40ns | 30mA | -40°C ~ 150°C | - | - | Bidirectional | Surface Mount | 6-SOIC |
|
L18P005S12SENSOR CURRENT HALL 5A AC/DC |
0 |
|
|
L18PXXXS12 | Module | Bulk | Active | AC/DC | Hall Effect, Open Loop | 5A | 1 | Ratiometric, Voltage | - | DC ~ 100kHz | ±1% | - | 12V | 5µs | 15mA | -30°C ~ 80°C | - | - | Bidirectional | Through Hole | - |
|
CQ3201CORELESS CURENT SENSOR / 20A W/S |
0 |
|
|
- | 24-LSSOP (0.220", 5.60mm Width), 10 Leads | Tape & Reel (TR) | Obsolete | AC/DC | Hall Effect, Open Loop | 10.1A | 1 | Ratiometric, Voltage | 130mV/A | - | - | ±1.3% | 3.3V | 0.5µs | 6.2mA | -40°C ~ 90°C | - | - | Bidirectional | Surface Mount | 24-VSOP |
|
L18P060S05RSENSOR CURRENT HALL 60A AC/DC |
0 |
|
|
L18PXXXS05 | Module | Bulk | Active | AC/DC | Hall Effect, Open Loop | 60A | 1 | Ratiometric, Voltage | - | DC ~ 100kHz | ±1% | - | 5V | 5µs | 15mA | -30°C ~ 80°C | - | - | Bidirectional | Through Hole | - |
|
L08P100D15M1SENSOR CURRENT HALL 100A AC/DC |
0 |
|
|
- | Module, Single Pass Through | Bulk | Active | AC/DC | Hall Effect, Open Loop | 100A | 1 | Ratiometric, Voltage | - | DC ~ 100kHz | ±1% | - | ±15V | 10µs | 12mA | -10°C ~ 80°C | - | - | Bidirectional | Through Hole | - |
|
L08P200D15WSENSOR CURRENT HALL 200A AC/DC |
0 |
|
|
- | Module, Single Pass Through | Bulk | Active | AC/DC | Hall Effect, Open Loop | 200A | 1 | Ratiometric, Voltage | - | - | ±1% | - | 15V | 50µs | 20mA | -20°C ~ 80°C | - | - | Bidirectional | Through Hole | - |
|
L08P150D15M1SENSOR |
0 |
|
|
- | Module | Tray | Active | AC/DC | Hall Effect, Open Loop | 150A | 1 | Ratiometric, Voltage | - | DC ~ 100kHz | ±1% | - | 15V | 10µs | 12mA | -10°C ~ 80°C | - | - | Bidirectional | Through Hole | - |
|
L08P050D15IPVCURRENT SENSOR (50A; 15V) |
0 |
|
|
- | Module, Single Pass Through | Tray | Active | AC/DC | Hall Effect, Open Loop | 50A | 1 | Ratiometric, Voltage | - | - | ±1% | - | ±12V ~ 15V | 5µs | 20mA | -40°C ~ 80°C | - | - | Bidirectional | Through Hole | - |
|
L08P300D15IPVWCURRENT SENSOR (300A; 15V) |
0 |
|
|
- | Module, Single Pass Through | Bulk | Active | AC/DC | Hall Effect, Open Loop | 300A | 1 | Ratiometric, Voltage | - | - | ±1% | - | ±12V ~ 18V | 5µs | 20mA | -40°C ~ 80°C | - | - | Bidirectional | Through Hole | - |
|
|
L08P050D15SENSOR CURRENT HALL 50A AC/DC |
0 |
|
|
- | Module | Bulk | Obsolete | AC/DC | Hall Effect, Open Loop | 50A | 1 | Ratiometric, Voltage | - | DC ~ 100kHz | ±1% | - | ±15V | 10µs | 12mA | -10°C ~ 80°C | - | - | Bidirectional | Through Hole | - |
|
|
L08P150D15SENSOR CURRENT HALL 150A AC/DC |
0 |
|
|
- | Module | Bulk | Obsolete | AC/DC | Hall Effect, Open Loop | 150A | 1 | Ratiometric, Voltage | - | DC ~ 100kHz | ±1% | - | ±15V | 10µs | 12mA | -10°C ~ 80°C | - | - | Bidirectional | Through Hole | - |
|
|
L08P200D15SENSOR CURRENT HALL 200A AC/DC |
0 |
|
|
- | Module | Bulk | Obsolete | AC/DC | Hall Effect, Open Loop | 200A | 1 | Ratiometric, Voltage | - | DC ~ 100kHz | ±1% | - | 15V | 10µs | 12mA | -20°C ~ 80°C | - | - | Bidirectional | Through Hole | - |
|
|
L08P100D15SENSOR CURRENT HALL 100A AC/DC |
0 |
|
|
- | Module | Bulk | Obsolete | AC/DC | Hall Effect, Open Loop | 100A | 1 | Ratiometric, Voltage | - | DC ~ 100kHz | ±1% | - | ±15V | 10µs | 12mA | -10°C ~ 80°C | - | - | Bidirectional | Through Hole | - |
|
L18P010S05SENSOR CURRENT HALL 10A AC/DC |
0 |
|
|
L18PXXXS05 | Module | Bulk | Active | AC/DC | Hall Effect, Open Loop | 10A | 1 | Ratiometric, Voltage | - | DC ~ 100kHz | ±1% | - | 5V | 5µs | 15mA | -30°C ~ 80°C | - | - | Bidirectional | Through Hole | - |
|
HLSR 16-PW-081TRANSDUCER |
0 |
|
|
- | - | Bulk | Active | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
TMCS1101A2BQDTCURRENT SENSOR |
0 |
|
|
- | 8-SOIC (0.154", 3.90mm Width) | Tape & Reel (TR) | Obsolete | AC/DC | Hall Effect | 22.5A | 1 | Ratiometric, Voltage | 100mV/A | 80kHz | ±0.05% | - | 3V ~ 5.5V | 6.5µs | 6mA | -40°C ~ 125°C | - | - | Bidirectional | Surface Mount | 8-SOIC |
|
T60404N4647X661CURRENT SENSOR, 25A, 3 PRI PINS, |
0 |
|
|
- | 10-DIP Module | Box | Active | AC/DC | Closed Loop | 25A | 1 | Ratiometric, Voltage | - | DC ~ 200kHz | ±0.1% | ±0.7% | 4.75V ~ 5.25V | 300ns | 15mA | -40°C ~ 85°C | - | - | Unidirectional | Through Hole | - |
Category Overview
Current Sensors Products & Selection Guide
Current Sensors are widely used in industrial automation, automotive electronics, communication equipment, consumer electronics, new energy systems, and many other electronic applications. We offer products from multiple manufacturers, packages, and specifications to help engineers and buyers compare and source suitable components.
Use the manufacturer, key specification, availability, and Datasheet filters to narrow down the right Current Sensors. If the exact part is not listed, submit an inquiry and our team can help check stock, lead time, and suitable alternatives.
FAQ
How do I choose the right Current Sensors?
Start with the required electrical specifications, package, operating temperature, application conditions, and manufacturer preference, then compare availability and lead time.
Can I order based on the stock shown on this page?
Inventory can change with supply conditions. For project or volume requirements, please submit an inquiry so current stock, pricing, and lead time can be confirmed.
What if the exact part number I need is not listed?
Send us the part number and required quantity. We can help source hard-to-find parts and suggest suitable alternatives based on key specifications.
Do you provide Datasheets and technical documents?
Yes. Use the Datasheet links in the product list to view available technical documents. If a document is unavailable, contact us and we can help check it.