Current Sensors
| Photo | Mfr. Part # | Availability | Quantity | Datasheet | Series | Package/Case | Packaging | Product Status | For Measuring | Sensor Type | Current - Sensing | Number of Channels | Output | Sensitivity | Frequency | Linearity | Accuracy | Voltage - Supply | Response Time | Current - Supply (Max) | Operating Temperature | Grade | Qualification | Polarization | Mounting Type | Supplier Device Package |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
|
L12P025D15SENSOR CURRENT HALL 25A AC/DC |
0 |
|
|
- | Module | Bulk | Active | AC/DC | Hall Effect, Open Loop | 25A | 1 | Ratiometric, Voltage | - | DC ~ 50kHz | ±1% | ±1% | ±15V | 3µs | 15mA | -30°C ~ 80°C | - | - | Bidirectional | Through Hole | - |
|
T60404N4646X6644646X664 |
0 |
|
|
- | 10-DIP Module | Box | Active | AC/DC | Closed Loop | 50A | 1 | Voltage | - | DC ~ 200kHz | ±0.1% | ±0.7% | 4.75V ~ 5.25V | 300ns | 15mA | -40°C ~ 85°C | - | - | Bidirectional | Through Hole | - |
|
L03S100D15WJCURRENT SENSOR (100A; 15V) |
0 |
|
|
L03S | Module, Single Pass Through | Bulk | Active | AC/DC | Hall Effect, Closed Loop | 100A | 1 | Ratiometric, Voltage | - | - | ±1% | - | ±12V ~ 15V | 10µs | 20mA | -10°C ~ 80°C | - | - | Bidirectional | Chassis Mount | - |
|
S22P015S05M2SENSOR CURRENT HALL 15A AC/DC |
0 |
|
|
- | Module | Bulk | Active | AC/DC | Hall Effect, Closed Loop | 15A | 1 | Ratiometric, Voltage | - | DC ~ 100kHz | ±0.2% | - | 5V | 1µs | 12.5mA | -10°C ~ 85°C | - | - | Bidirectional | Through Hole | - |
|
T60404N4648X400CURRENT SENSOR, 25A, 3 PRI PINS, |
0 |
|
|
- | 9-DIP Module | Box | Active | AC/DC | Closed Loop | 25A | 1 | Ratiometric, Current | - | DC ~ 200kHz | ±0.1% | ±0.5% | ±11.4V ~ 15.75V | 500µs | 15mA | -40°C ~ 85°C | - | - | Unidirectional | Through Hole | - |
|
L07P003S05SENSOR CURRENT HALL 3A AC/DC |
0 |
|
|
L07P | Module | Bulk | Active | AC/DC | Hall Effect, Open Loop | 3A | 1 | Ratiometric, Voltage | - | DC ~ 100kHz | ±1% | - | 5V | 5µs | 30mA | -30°C ~ 80°C | - | - | Bidirectional | Through Hole | - |
|
HXS 20-NP/SP7SENSORS |
0 |
|
|
HXS | Module | Bulk | Not For New Designs | AC/DC | Hall Effect, Open Loop | 20A | 1 | Analog Voltage | 625mV/A | DC ~ 50kHz | ±0.5% | ±1% | 5V | 5µs | 19mA | -40°C ~ 105°C | - | - | Unidirectional | Through Hole | - |
|
HXS 20-NP/SP30SENSORS |
0 |
|
|
HXS | Module | Bulk | Not For New Designs | AC/DC | Hall Effect | 20A | 1 | Analog Voltage | 625mV/A | DC ~ 50kHz | ±0.5% | ±1% | 5V | 3µs | 19mA | -40°C ~ 85°C | - | - | Unidirectional | Through Hole | - |
|
S22P025S05M2SENSOR CURRENT HALL 25A AC/DC |
0 |
|
|
- | Module, Single Pass Through | Bulk | Active | AC/DC | Hall Effect, Closed Loop | 25A | 1 | Ratiometric, Voltage | - | DC ~ 100kHz | ±0.2% | - | 5V | 1µs | 12.5mA | -10°C ~ 85°C | - | - | Bidirectional | Through Hole | - |
|
L03S200D15WJCURRENT SENSOR (200A; 15V) |
0 |
|
|
L03S | Module, Single Pass Through | Bulk | Active | AC/DC | Hall Effect, Closed Loop | 200A | 1 | Ratiometric, Voltage | - | - | ±1% | - | ±12V ~ 15V | 10µs | 20mA | -10°C ~ 80°C | - | - | Bidirectional | Chassis Mount | - |
|
LA01P170S05SENSOR |
0 |
|
|
LA01P | Module | Tray | Obsolete | AC/DC | Hall Effect, Open Loop | 170A | 1 | Ratiometric, Voltage | 12.5mV/A | DC ~ 400kHz | ±1% | ±1% | 4.5V ~ 5.5V | 1µs | 10mA | -40°C ~ 90°C | - | - | Bidirectional | Through Hole | - |
|
L03S100D15WMSENSOR |
0 |
|
|
L03S | Module | Tray | Obsolete | AC/DC | Hall Effect, Open Loop | 100A | 1 | Ratiometric, Voltage | - | DC ~ 100kHz | ±1% | - | 15V | 10µs | 20mA | -10°C ~ 80°C | - | - | Bidirectional | Chassis Mount | - |
|
L07P010S05SENSOR CURRENT HALL 10A AC/DC |
0 |
|
|
L07P | Module | Bulk | Active | AC/DC | Hall Effect, Open Loop | 10A | 1 | Ratiometric, Voltage | - | DC ~ 100kHz | ±1% | - | 5V | 5µs | 30mA | -30°C ~ 80°C | - | - | Bidirectional | Through Hole | - |
|
HLSR 100-P/SP10TRANSDUCER |
0 |
|
|
HLSR | Module | Bulk | Active | AC/DC | Hall Effect, Open Loop | 100A | 1 | Voltage | 8mV/A | DC ~ 90kHz | ±0.5% | ±3.8% | 4.5V ~ 5.5V | 2.5µs | 25mA | -40°C ~ 105°C | - | - | Unidirectional | Through Hole | - |
|
HLSR 80-P/SP10TRANSDUCER |
0 |
|
|
HLSR | Module | Bulk | Active | AC/DC | Hall Effect, Open Loop | 80A | 1 | Voltage | 10mV/A | DC ~ 90kHz | ±0.5% | ±3.8% | 4.5V ~ 5.5V | 2.5µs | 25mA | -40°C ~ 105°C | - | - | Unidirectional | Through Hole | - |
|
L03S300D15WJCURRENT SENSOR (300A; 15V) |
0 |
|
|
L03S | Module, Single Pass Through | Bulk | Active | AC/DC | Hall Effect, Closed Loop | 300A | 1 | Ratiometric, Voltage | - | - | ±1% | - | ±12V ~ 15V | 10µs | 20mA | -10°C ~ 80°C | - | - | Bidirectional | Chassis Mount | - |
|
|
S22P006S05SENSOR CURRENT HALL 6A AC/DC |
0 |
|
|
- | Module | Bulk | Obsolete | AC/DC | Hall Effect, Closed Loop | 6A | 1 | Ratiometric, Voltage | - | DC ~ 100kHz | ±0.2% | - | 5V | 1µs | 12.5mA | -10°C ~ 85°C | - | - | Bidirectional | Through Hole | - |
|
HLSR 20-P/SP1TRANSDUCER |
0 |
|
|
HLSR | Module | Bulk | Active | AC/DC | Hall Effect, Open Loop | 20A | 1 | Voltage | 23mV/A | DC ~ 240kHz | ±0.5% | ±1% | 4.5V ~ 5.5V | 3.5µs | 25mA | -40°C ~ 105°C | - | - | Unidirectional | Through Hole | - |
|
L03S200D15WMSENSOR |
0 |
|
|
L03S | Module | Tray | Obsolete | AC/DC | Hall Effect, Open Loop | 200A | 1 | Ratiometric, Voltage | - | DC ~ 100kHz | ±1% | - | 15V | 10µs | 20mA | -10°C ~ 80°C | - | - | Bidirectional | Chassis Mount | - |
|
CKSR 25-NP/SP3TRANSDUCER |
0 |
|
|
CKSR | Module | Bulk | Active | AC/DC | Closed Loop | 25A | 1 | Voltage | 25mV/A | DC ~ 300kHz | ±0.1% | ±0.8% | 4.75V ~ 5.25V | 300ns | - | -40°C ~ 105°C | - | - | Unidirectional | Through Hole | - |
Category Overview
Current Sensors Products & Selection Guide
Current Sensors are widely used in industrial automation, automotive electronics, communication equipment, consumer electronics, new energy systems, and many other electronic applications. We offer products from multiple manufacturers, packages, and specifications to help engineers and buyers compare and source suitable components.
Use the manufacturer, key specification, availability, and Datasheet filters to narrow down the right Current Sensors. If the exact part is not listed, submit an inquiry and our team can help check stock, lead time, and suitable alternatives.
FAQ
How do I choose the right Current Sensors?
Start with the required electrical specifications, package, operating temperature, application conditions, and manufacturer preference, then compare availability and lead time.
Can I order based on the stock shown on this page?
Inventory can change with supply conditions. For project or volume requirements, please submit an inquiry so current stock, pricing, and lead time can be confirmed.
What if the exact part number I need is not listed?
Send us the part number and required quantity. We can help source hard-to-find parts and suggest suitable alternatives based on key specifications.
Do you provide Datasheets and technical documents?
Yes. Use the Datasheet links in the product list to view available technical documents. If a document is unavailable, contact us and we can help check it.