Current Sensors
| Photo | Mfr. Part # | Availability | Quantity | Datasheet | Series | Package/Case | Packaging | Product Status | For Measuring | Sensor Type | Current - Sensing | Number of Channels | Output | Sensitivity | Frequency | Linearity | Accuracy | Voltage - Supply | Response Time | Current - Supply (Max) | Operating Temperature | Grade | Qualification | Polarization | Mounting Type | Supplier Device Package |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
L31S400S05FSSENSOR CURRENT HALL 400A AC/DC |
0 |
|
|
L31SXXXS05S | Module, Single Pass Through | Bulk | Active | AC/DC | Hall Effect, Open Loop | 400A | 1 | Ratiometric, Voltage | - | DC ~ 100kHz | ±0.5% | - | 5V | 5µs | 15mA | -40°C ~ 85°C | - | - | Bidirectional | Chassis Mount | - |
|
L03S700D15WJCURRENT SENSOR (700A; 15V) |
0 |
|
|
L03S | Module, Single Pass Through | Bulk | Active | AC/DC | Hall Effect, Closed Loop | 700A | 1 | Ratiometric, Voltage | - | - | ±1% | - | ±12V ~ 15V | 10µs | 20mA | -10°C ~ 80°C | - | - | Bidirectional | Chassis Mount | - |
|
L03S700D15WMCURRENT SENSOR (700A; 15V) |
0 |
|
|
L03S | Module, Single Pass Through | Bulk | Active | AC/DC | Hall Effect, Open Loop | 700A | 1 | Ratiometric, Voltage | - | - | ±1% | - | ±12V ~ 15V | 10µs | 20mA | -20°C ~ 80°C | - | - | Bidirectional | Chassis Mount | - |
|
|
F01P006S05SENSOR CURRENT FLUX GATE 6A AC |
0 |
|
|
F01P | Module | Bulk | Obsolete | AC | Flux Gate, Closed Loop | 6A | 1 | Ratiometric, Voltage | 104.2mV/A | 300kHz | ±1% | ±2.5% | 5V | 0.3µs | 25mA | -40°C ~ 105°C | - | - | Bidirectional | Through Hole | - |
|
|
F02P006S05SENSOR CURRENT FLUX GATE 6A AC |
0 |
|
|
F02P | Module | Bulk | Obsolete | AC | Flux Gate, Closed Loop | 6A | 1 | Ratiometric, Voltage | 104.2mV/A | 300kHz | ±1% | ±1.7% | 5V | 0.3µs | 25mA | -40°C ~ 105°C | - | - | Bidirectional | Through Hole | - |
|
|
F03P006S05SENSOR CURRENT FLUX GATE 6A AC |
0 |
|
|
F03P | Module | Bulk | Obsolete | AC | Flux Gate, Closed Loop | 6A | 1 | Ratiometric, Voltage | 104.2mV/A | 300kHz | ±1% | ±1.7% | 5V | 0.3µs | 25mA | -40°C ~ 105°C | - | - | Bidirectional | Through Hole | - |
|
|
F03P025S05SENSOR CURRENT FLUX GATE 25A AC |
0 |
|
|
F03P | Module | Bulk | Obsolete | AC | Flux Gate, Closed Loop | 25A | 1 | Ratiometric, Voltage | 25mV/A | 300kHz | ±1% | ±1% | 5V | 0.3µs | 35mA | -40°C ~ 105°C | - | - | Bidirectional | Through Hole | - |
|
CKSR 50-NP/SP1TRANSDUCER |
0 |
|
|
CKSR | Module | Bulk | Active | AC/DC | Closed Loop | 50A | 1 | Voltage | 0.0125mV/A | DC ~ 300kHz | ±0.1% | ±1.2% | 4.75V ~ 5.25V | - | - | -40°C ~ 105°C | - | - | Unidirectional | Through Hole | - |
|
L03S600D15WMSENSOR |
0 |
|
|
L03S | Module | Tray | Obsolete | AC/DC | Hall Effect, Open Loop | 600A | 1 | Ratiometric, Voltage | - | DC ~ 100kHz | ±1% | - | 15V | 10µs | 20mA | -10°C ~ 80°C | - | - | Bidirectional | Chassis Mount | - |
|
L31S500S05FSSENSOR CURRENT HALL 500A AC/DC |
0 |
|
|
L31SXXXS05S | Module, Single Pass Through | Bulk | Active | AC/DC | Hall Effect, Open Loop | 500A | 1 | Ratiometric, Voltage | - | DC ~ 100kHz | ±0.5% | - | 5V | 5µs | 15mA | -40°C ~ 85°C | - | - | Bidirectional | Chassis Mount | - |
|
L10P003D15SENSOR CURRENT HALL 3A DC |
0 |
|
|
- | Module | Bulk | Obsolete | DC | Hall Effect, Open Loop | 3A | 1 | Ratiometric, Voltage | - | DC ~ 50kHz | ±1% | ±1% | ±15V | 5µs | 12mA | -10°C ~ 80°C | - | - | Unidirectional | Through Hole | - |
|
L10P005D15SENSOR CURRENT HALL 5A DC |
0 |
|
|
- | Module | Bulk | Obsolete | DC | Hall Effect, Open Loop | 5A | 1 | Ratiometric, Voltage | - | DC ~ 50kHz | ±1% | ±1% | ±15V | 5µs | 12mA | -10°C ~ 80°C | - | - | Unidirectional | Through Hole | - |
|
L10P015D15SENSOR CURRENT HALL 15A DC |
0 |
|
|
- | Module | Bulk | Obsolete | DC | Hall Effect, Open Loop | 15A | 1 | Ratiometric, Voltage | - | DC ~ 50kHz | ±1% | ±1% | ±15V | 5µs | 12mA | -10°C ~ 80°C | - | - | Unidirectional | Through Hole | - |
|
L10P020D15SENSOR CURRENT HALL 20A DC |
0 |
|
|
- | Module | Bulk | Obsolete | DC | Hall Effect, Open Loop | 20A | 1 | Ratiometric, Voltage | - | DC ~ 50kHz | ±1% | ±1% | ±15V | 5µs | 12mA | -10°C ~ 80°C | - | - | Unidirectional | Through Hole | - |
|
L10P025D15SENSOR CURRENT HALL 25A DC |
0 |
|
|
- | Module | Bulk | Obsolete | DC | Hall Effect, Open Loop | 25A | 1 | Ratiometric, Voltage | - | DC ~ 50kHz | ±1% | ±1% | ±15V | 5µs | 12mA | -10°C ~ 80°C | - | - | Unidirectional | Through Hole | - |
|
L16P003D15SENSOR CURRENT HALL 3A DC |
0 |
|
|
- | Module | Bulk | Obsolete | DC | Hall Effect, Open Loop | 3A | 1 | Ratiometric, Voltage | - | DC ~ 35kHz | ±1% | ±1% | ±15V | 5µs | 12mA | -10°C ~ 80°C | - | - | Unidirectional | Through Hole | - |
|
L16P005D15SENSOR CURRENT HALL 5A DC |
0 |
|
|
- | Module | Bulk | Obsolete | DC | Hall Effect, Open Loop | 5A | 1 | Ratiometric, Voltage | - | DC ~ 35kHz | ±1% | ±1% | ±15V | 5µs | 12mA | -10°C ~ 80°C | - | - | Unidirectional | Through Hole | - |
|
L16P010D15SENSOR CURRENT HALL 10A DC |
0 |
|
|
- | Module | Bulk | Obsolete | DC | Hall Effect, Open Loop | 10A | 1 | Ratiometric, Voltage | - | DC ~ 35kHz | ±1% | ±1% | ±15V | 5µs | 12mA | -10°C ~ 80°C | - | - | Unidirectional | Through Hole | - |
|
L16P015D15SENSOR CURRENT HALL 15A DC |
0 |
|
|
- | Module | Bulk | Obsolete | DC | Hall Effect, Open Loop | 15A | 1 | Ratiometric, Voltage | - | DC ~ 35kHz | ±1% | ±1% | ±15V | 5µs | 12mA | -10°C ~ 80°C | - | - | Unidirectional | Through Hole | - |
|
L16P025D15SENSOR CURRENT HALL 25A DC |
0 |
|
|
- | Module | Bulk | Obsolete | DC | Hall Effect, Open Loop | 25A | 1 | Ratiometric, Voltage | - | DC ~ 35kHz | ±1% | ±1% | ±15V | 5µs | 12mA | -10°C ~ 80°C | - | - | Unidirectional | Through Hole | - |
Category Overview
Current Sensors Products & Selection Guide
Current Sensors are widely used in industrial automation, automotive electronics, communication equipment, consumer electronics, new energy systems, and many other electronic applications. We offer products from multiple manufacturers, packages, and specifications to help engineers and buyers compare and source suitable components.
Use the manufacturer, key specification, availability, and Datasheet filters to narrow down the right Current Sensors. If the exact part is not listed, submit an inquiry and our team can help check stock, lead time, and suitable alternatives.
FAQ
How do I choose the right Current Sensors?
Start with the required electrical specifications, package, operating temperature, application conditions, and manufacturer preference, then compare availability and lead time.
Can I order based on the stock shown on this page?
Inventory can change with supply conditions. For project or volume requirements, please submit an inquiry so current stock, pricing, and lead time can be confirmed.
What if the exact part number I need is not listed?
Send us the part number and required quantity. We can help source hard-to-find parts and suggest suitable alternatives based on key specifications.
Do you provide Datasheets and technical documents?