Current Sensors
| Photo | Mfr. Part # | Availability | Quantity | Datasheet | Series | Package/Case | Packaging | Product Status | For Measuring | Sensor Type | Current - Sensing | Number of Channels | Output | Sensitivity | Frequency | Linearity | Accuracy | Voltage - Supply | Response Time | Current - Supply (Max) | Operating Temperature | Grade | Qualification | Polarization | Mounting Type | Supplier Device Package |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
HLSR 50-PW-080TRANSDUCER |
0 |
|
|
HLSR | Module | Bulk | Active | AC/DC | Open Loop | 16A | 1 | Voltage | - | - | ±0.5% | - | 4.5V ~ 5.5V | - | 31mA | -40°C ~ 105°C | - | - | Bidirectional | Through Hole | - |
|
HLSR 40-PW-010TRANSDUCER |
0 |
|
|
HLSR | Module | Bulk | Active | AC/DC | Open Loop | 16A | 1 | Voltage | - | - | ±0.5% | - | 4.5V ~ 5.5V | - | 31mA | -40°C ~ 105°C | - | - | Bidirectional | Through Hole | - |
|
T60404N4647X160CURRENT SENSOR,100A, PRI OPEN, 5 |
0 |
|
|
- | Module, Single Pass Through | Box | Active | AC/DC | Closed Loop | 100A | 1 | Ratiometric, Voltage | - | DC ~ 100kHz | ±0.1% | ±1% | 4.75V ~ 5.25V | 1µs | 16mA | -40°C ~ 85°C | - | - | Unidirectional | Through Hole | - |
|
|
F03P015S05SENSOR CURRENT FLUX GATE 15A AC |
0 |
|
|
F03P | Module | Bulk | Obsolete | AC | Flux Gate, Closed Loop | 15A | 1 | Ratiometric, Voltage | 41.7mV/A | 300kHz | ±1% | ±1.2% | 5V | 0.3µs | 30mA | -40°C ~ 105°C | - | - | Bidirectional | Through Hole | - |
|
L31S200S05FSSENSOR CURRENT HALL 200A AC/DC |
0 |
|
|
L31SXXXS05S | Module, Single Pass Through | Bulk | Active | AC/DC | Hall Effect, Open Loop | 200A | 1 | Ratiometric, Voltage | - | DC ~ 100kHz | ±0.5% | - | 5V | 5µs | 15mA | -40°C ~ 85°C | - | - | Bidirectional | Chassis Mount | - |
|
L03S400D15WMSENSOR |
0 |
|
|
L03S | Module | Tray | Obsolete | AC/DC | Hall Effect, Open Loop | 400A | 1 | Ratiometric, Voltage | - | DC ~ 100kHz | ±1% | - | 15V | 10µs | 20mA | -10°C ~ 80°C | - | - | Bidirectional | Chassis Mount | - |
|
26461INA226AIDGSR, I2C interface |
10 |
|
|
- | Module | Bulk | Active | AC/DC | Current Sensor | 820mA | 1 | I2C | - | - | - | ±0.1% | 2.7V ~ 5.5V | - | 330µA | -40°C ~ 125°C | - | - | Bidirectional | Chassis Mount | Module |
|
L03S600D15WJCURRENT SENSOR (600A; 15V) |
0 |
|
|
L03S | Module, Single Pass Through | Bulk | Active | AC/DC | Hall Effect, Closed Loop | 600A | 1 | Ratiometric, Voltage | - | - | ±1% | - | ±12V ~ 15V | 10µs | 20mA | -10°C ~ 80°C | - | - | Bidirectional | Chassis Mount | - |
|
L07P010D15SSENSOR CURRENT HALL |
0 |
|
|
L07P | Module | Bulk | Active | AC/DC | Hall Effect, Open Loop | 10A | 2 | Ratiometric, Voltage | - | - | ±1% | - | ±15V | 5µs | 30mA | -30°C ~ 80°C | - | - | Bidirectional | Through Hole | - |
|
L07P005D15SSENSOR CURRENT HALL |
0 |
|
|
L07P | Module | Bulk | Active | AC/DC | Hall Effect, Open Loop | 5A | 2 | Ratiometric, Voltage | - | - | ±1% | - | ±15V | 5µs | 30mA | -30°C ~ 80°C | - | - | Bidirectional | Through Hole | - |
|
L07P030D15SSENSOR CURRENT HALL |
0 |
|
|
L07P | Module | Bulk | Active | AC/DC | Hall Effect, Open Loop | 30A | 2 | Ratiometric, Voltage | - | - | ±1% | - | ±15V | 5µs | 30mA | -30°C ~ 80°C | - | - | Bidirectional | Through Hole | - |
|
L07P003D15SSENSOR CURRENT HALL |
0 |
|
|
L07P | Module | Bulk | Active | AC/DC | Hall Effect, Open Loop | 3A | 2 | Ratiometric, Voltage | - | - | ±1% | - | ±15V | 5µs | 30mA | -30°C ~ 80°C | - | - | Bidirectional | Through Hole | - |
|
L07P020D15SSENSOR CURRENT HALL |
0 |
|
|
L07P | Module | Bulk | Active | AC/DC | Hall Effect, Open Loop | 20A | 2 | Ratiometric, Voltage | - | - | ±1% | - | ±15V | 5µs | 30mA | -30°C ~ 80°C | - | - | Bidirectional | Through Hole | - |
|
L07P015D15SSENSOR CURRENT HALL |
0 |
|
|
L07P | Module | Bulk | Active | AC/DC | Hall Effect, Open Loop | 15A | 2 | Ratiometric, Voltage | - | - | ±1% | - | ±15V | 5µs | 30mA | -30°C ~ 80°C | - | - | Bidirectional | Through Hole | - |
|
L07P025D15SSENSOR CURRENT HALL |
0 |
|
|
L07P | Module | Bulk | Active | AC/DC | Hall Effect, Open Loop | 25A | 2 | Ratiometric, Voltage | - | - | ±1% | - | ±15V | 5µs | 30mA | -30°C ~ 80°C | - | - | Bidirectional | Through Hole | - |
|
L31S300S05FSSENSOR CURRENT HALL 300A AC/DC |
0 |
|
|
L31SXXXS05S | Module, Single Pass Through | Bulk | Active | AC/DC | Hall Effect, Open Loop | 300A | 1 | Ratiometric, Voltage | - | DC ~ 100kHz | ±0.5% | - | 5V | 5µs | 15mA | -40°C ~ 85°C | - | - | Bidirectional | Chassis Mount | - |
|
S23P50/100D15M1SENSOR CURRENT HALL 100A AC/DC |
0 |
|
|
- | Module | Bulk | Active | AC/DC | Hall Effect, Closed Loop | 100A | 1 | Ratiometric, Current | - | DC ~ 100kHz | ±0.15% | ±0.25% | ±12V ~ 15V | 0.5µs | 50mA | -40°C ~ 85°C | - | - | Bidirectional | Through Hole | - |
|
L03S500D15WMSENSOR |
0 |
|
|
L03S | Module | Tray | Obsolete | AC/DC | Hall Effect, Open Loop | 500A | 1 | Ratiometric, Voltage | - | DC ~ 100kHz | ±1% | - | 15V | 10µs | 20mA | -10°C ~ 80°C | - | - | Bidirectional | Chassis Mount | - |
|
TLI4970D025T5XUMA1SENSOR CURRENT HALL 25A 8TISON |
0 |
|
|
- | 8-PowerTDFN | Tape & Reel (TR) | Obsolete | AC/DC | Hall Effect, Differential | 25A | 1 | SPI | - | DC ~ 18kHz | ±1.6% | ±3.5% | 3.1V ~ 3.5V | 57µs | 20mA | -40°C ~ 85°C | Automotive | AEC-Q100 | Unidirectional | Surface Mount | PG-TISON-8-1 |
|
T60404N4646X4134646X413 |
0 |
|
|
- | 9-DIP Module | Box | Active | AC/DC | Closed Loop | 100A | 1 | Current | - | DC ~ 200kHz | ±0.1% | ±0.5% | ±11.4V ~ 15.75V | 500ns | 18.5mA | -40°C ~ 70°C | - | - | Bidirectional | Through Hole | - |
Category Overview
Current Sensors Products & Selection Guide
Current Sensors are widely used in industrial automation, automotive electronics, communication equipment, consumer electronics, new energy systems, and many other electronic applications. We offer products from multiple manufacturers, packages, and specifications to help engineers and buyers compare and source suitable components.
Use the manufacturer, key specification, availability, and Datasheet filters to narrow down the right Current Sensors. If the exact part is not listed, submit an inquiry and our team can help check stock, lead time, and suitable alternatives.
FAQ
How do I choose the right Current Sensors?
Start with the required electrical specifications, package, operating temperature, application conditions, and manufacturer preference, then compare availability and lead time.
Can I order based on the stock shown on this page?
Inventory can change with supply conditions. For project or volume requirements, please submit an inquiry so current stock, pricing, and lead time can be confirmed.
What if the exact part number I need is not listed?
Send us the part number and required quantity. We can help source hard-to-find parts and suggest suitable alternatives based on key specifications.
Do you provide Datasheets and technical documents?
Yes. Use the Datasheet links in the product list to view available technical documents. If a document is unavailable, contact us and we can help check it.