TRIACs
| Photo | Mfr. Part # | Availability | Quantity | Datasheet | Series | Package/Case | Packaging | Product Status | Triac Type | Voltage - Off State | Current - On State (It (RMS)) (Max) | Voltage - Gate Trigger (Vgt) (Max) | Current - Non Rep. Surge 50, 60Hz (Itsm) | Current - Gate Trigger (Igt) (Max) | Current - Hold (Ih) (Max) | Configuration | Operating Temperature | Grade | Qualification | Mounting Type | Supplier Device Package |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Z0103NN5AA4TRIAC SENS GATE 800V 1A SOT223 |
3,900 |
|
|
- | TO-261-4, TO-261AA | Tape & Reel (TR) | Active | Logic - Sensitive Gate | 800 V | 1 A | 1.3 V | 8A, 8.5A | 3 mA | 7 mA | Single | -40°C ~ 125°C (TJ) | - | - | Surface Mount | SOT-223 |
|
Z0107MNT1GTRIAC SENS GATE 600V 1A SOT223 |
9,733 |
|
|
- | TO-261-4, TO-261AA | Tape & Reel (TR) | Active | Logic - Sensitive Gate | 600 V | 1 A | 1.3 V | 8A @ 60Hz | 5 mA | 10 mA | Single | -40°C ~ 125°C (TJ) | - | - | Surface Mount | SOT-223 |
|
Z0103MNT1GTRIAC SENS GATE 600V 1A SOT223 |
26,794 |
|
|
- | TO-261-4, TO-261AA | Tape & Reel (TR) | Active | Logic - Sensitive Gate | 600 V | 1 A | 1.3 V | 8A @ 60Hz | 3 mA | 10 mA | Single | -40°C ~ 125°C (TJ) | - | - | Surface Mount | SOT-223 |
|
T405-800B-TRTRIAC SENS GATE 800V 4A DPAK |
3,836 |
|
|
- | TO-252-3, DPAK (2 Leads + Tab), SC-63 | Tape & Reel (TR) | Active | Logic - Sensitive Gate | 800 V | 4 A | 1.3 V | 30A, 31A | 5 mA | 10 mA | Single | -40°C ~ 125°C (TJ) | - | - | Surface Mount | DPAK |
|
T835-600B-TRTRIAC ALTERNISTOR 600V 8A DPAK |
9,310 |
|
|
Snubberless™ | TO-252-3, DPAK (2 Leads + Tab), SC-63 | Tape & Reel (TR) | Active | Alternistor - Snubberless | 600 V | 8 A | 1.3 V | 80A, 84A | 35 mA | 35 mA | Single | -40°C ~ 125°C (TJ) | - | - | Surface Mount | DPAK |
|
|
2N6073BGTRIAC SENS GATE 400V 4A TO225AA |
6,016 |
|
|
- | TO-225AA, TO-126-3 | Box | Active | Logic - Sensitive Gate | 400 V | 4 A | 2.5 V | 30A @ 60Hz | 3 mA | 15 mA | Single | -40°C ~ 110°C (TJ) | - | - | Through Hole | TO-225AA |
|
|
2N6075BGTRIAC SENS GATE 600V 4A TO225AA |
1,933 |
|
|
- | TO-225AA, TO-126-3 | Box | Active | Logic - Sensitive Gate | 600 V | 4 A | 2.5 V | 30A @ 60Hz | 3 mA | 15 mA | Single | -40°C ~ 110°C (TJ) | - | - | Through Hole | TO-225AA |
|
|
BTA08-600CWRGTRIAC ALTERNISTOR 600V 8A TO220 |
2,804 |
|
|
Snubberless™ | TO-220-3 | Tube | Active | Alternistor - Snubberless | 600 V | 8 A | 1.3 V | 80A, 84A | 35 mA | 35 mA | Single | -40°C ~ 125°C (TJ) | - | - | Through Hole | TO-220 |
|
T835H-6G-TRTRIAC ALTERNISTOR 600V 8A D2PAK |
380 |
|
|
Snubberless™ | TO-263-3, D2PAK (2 Leads + Tab), TO-263AB | Tape & Reel (TR) | Active | Alternistor - Snubberless | 600 V | 8 A | 1 V | 80A, 84A | 35 mA | 35 mA | Single | -40°C ~ 150°C (TJ) | - | - | Surface Mount | D2PAK |
|
|
BTA16-800BRGTRIAC 800V 16A TO220 |
3,715 |
|
|
- | TO-220-3 | Tray | Active | Standard | 800 V | 16 A | 1.3 V | 160A, 168A | 50 mA | 50 mA | Single | -40°C ~ 125°C (TJ) | - | - | Through Hole | TO-220 |
|
T1210-800G-TRTRIAC SENS GATE 800V 12A D2PAK |
3,414 |
|
|
- | TO-263-3, D2PAK (2 Leads + Tab), TO-263AB | Tape & Reel (TR) | Active | Logic - Sensitive Gate | 800 V | 12 A | 1.3 V | 120A, 126A | 10 mA | 15 mA | Single | -40°C ~ 125°C (TJ) | - | - | Surface Mount | D2PAK |
|
MAC4DHMT4GTRIAC SENS GATE 600V 4A TO252 |
22,320 |
|
|
- | TO-252-3, DPAK (2 Leads + Tab), SC-63 | Tape & Reel (TR) | Active | Logic - Sensitive Gate | 600 V | 4 A | 1.3 V | 40A @ 60Hz | 5 mA | 15 mA | Single | -40°C ~ 110°C (TJ) | - | - | Surface Mount | TO-252 (DPAK) |
|
Q4004D3RPTRIAC SENS GATE 400V 4A TO252 |
8,410 |
|
|
- | TO-252-3, DPAK (2 Leads + Tab), SC-63 | Tape & Reel (TR) | Active | Logic - Sensitive Gate | 400 V | 4 A | 1.3 V | 46A, 55A | 10 mA | 20 mA | Single | -40°C ~ 125°C (TJ) | - | - | Surface Mount | TO-252 (DPAK) |
|
MAC4DLMT4GTRIAC SENS GATE 600V 4A TO252 |
19,066 |
|
|
- | TO-252-3, DPAK (2 Leads + Tab), SC-63 | Tape & Reel (TR) | Active | Logic - Sensitive Gate | 600 V | 4 A | 1.3 V | 40A @ 60Hz | 3 mA | 15 mA | Single | -40°C ~ 110°C (TJ) | - | - | Surface Mount | TO-252 (DPAK) |
|
MAC4DSNT4GTRIAC SENS GATE 800V 4A TO252 |
4,180 |
|
|
- | TO-252-3, DPAK (2 Leads + Tab), SC-63 | Tape & Reel (TR) | Active | Logic - Sensitive Gate | 800 V | 4 A | 1.3 V | 40A @ 60Hz | 10 mA | 15 mA | Single | -40°C ~ 125°C (TJ) | - | - | Surface Mount | TO-252 (DPAK) |
|
|
BTA24-600BWRGTRIAC ALTERNISTOR 600V 25A TO220 |
7,706 |
|
|
Snubberless™ | TO-220-3 | Tube | Active | Alternistor - Snubberless | 600 V | 25 A | 1.3 V | 250A, 260A | 50 mA | 75 mA | Single | -40°C ~ 125°C (TJ) | - | - | Through Hole | TO-220 |
|
|
BTA24-600CWRGTRIAC ALTERNISTOR 600V 25A TO220 |
1,000 |
|
|
Snubberless™ | TO-220-3 | Tube | Active | Alternistor - Snubberless | 600 V | 25 A | 1.3 V | 250A, 260A | 35 mA | 50 mA | Single | -40°C ~ 125°C (TJ) | - | - | Through Hole | TO-220 |
|
|
BTA24-800CWRGTRIAC ALTERNISTOR 800V 25A TO220 |
5,697 |
|
|
Snubberless™ | TO-220-3 | Tube | Active | Alternistor - Snubberless | 800 V | 25 A | 1.3 V | 250A, 260A | 35 mA | 50 mA | Single | -40°C ~ 125°C (TJ) | - | - | Through Hole | TO-220 |
|
T2500DGTRIAC 400V 6A TO220AB |
3,057 |
|
|
- | TO-220-3 | Tube | Active | Standard | 400 V | 6 A | 2.5 V | 60A @ 60Hz | 25 mA | 30 mA | Single | -40°C ~ 125°C (TJ) | - | - | Through Hole | TO-220AB |
|
T3035H-6G-TRTRIAC ALTERNISTOR 600V 30A D2PAK |
2,000 |
|
|
Snubberless™ | TO-263-3, D2PAK (2 Leads + Tab), TO-263AB | Tape & Reel (TR) | Active | Alternistor - Snubberless | 600 V | 30 A | 1 V | 270A, 284A | 35 mA | 60 mA | Single | -40°C ~ 150°C (TJ) | - | - | Surface Mount | D2PAK |
Category Overview
TRIACs Products & Selection Guide
TRIACs are widely used in industrial automation, automotive electronics, communication equipment, consumer electronics, new energy systems, and many other electronic applications. We offer products from multiple manufacturers, packages, and specifications to help engineers and buyers compare and source suitable components.
Use the manufacturer, key specification, availability, and Datasheet filters to narrow down the right TRIACs. If the exact part is not listed, submit an inquiry and our team can help check stock, lead time, and suitable alternatives.
FAQ
How do I choose the right TRIACs?
Start with the required electrical specifications, package, operating temperature, application conditions, and manufacturer preference, then compare availability and lead time.
Can I order based on the stock shown on this page?
Inventory can change with supply conditions. For project or volume requirements, please submit an inquiry so current stock, pricing, and lead time can be confirmed.
What if the exact part number I need is not listed?
Send us the part number and required quantity. We can help source hard-to-find parts and suggest suitable alternatives based on key specifications.
Do you provide Datasheets and technical documents?
Yes. Use the Datasheet links in the product list to view available technical documents. If a document is unavailable, contact us and we can help check it.