| Photo | Mfr. Part # | Availability | Quantity | Datasheet | Series | Package/Case | Packaging | Product Status | For Measuring | Sensor Type | Current - Sensing | Number of Channels | Output | Sensitivity | Frequency | Linearity | Accuracy | Voltage - Supply | Response Time | Current - Supply (Max) | Operating Temperature | Grade | Qualification | Polarization | Mounting Type | Supplier Device Package |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
FG-R04-4BASENSOR CURRENT FLUX 40A IEC VRT |
147 |
|
|
FG | Module | Box | Active | AC/DC | Flux Gate, Open Loop | 50mA | 1 | Ratiometric, Voltage | 40V/A | DC ~ 55Hz | - | - | 4.75V ~ 5.25V | 250ms (AC), 1s (DC) | 13mA (Typ) | -40°C ~ 105°C | - | - | Bidirectional | Through Hole | - |
|
FG-R05-4BASENSOR CURRENT FLUX 40A IEC VRT |
110 |
|
|
FG | Module, Single Pass Through | Box | Active | AC/DC | Flux Gate, Open Loop | 50mA | 1 | Ratiometric, Voltage | 40V/A | DC ~ 55Hz | - | - | 4.75V ~ 5.25V | 250ms (AC), 1s (DC) | 13mA (Typ) | -40°C ~ 105°C | - | - | Bidirectional | Through Hole | - |
|
LZSR 200-TP/SP1CLOSED-LOOP CURRENT SENSOR 200A |
136 |
|
|
LZSR-TP/SP1 | Module | Bulk | Active | AC/DC | Closed Loop | 200A | 1 | Voltage | 3.125mV/A | DC ~ 200kHz | ±0.18% | - | 4.75V ~ 5.25V | - | - | -40°C ~ 85°C | - | - | Bidirectional | Through Hole | - |
|
RCM01-02RESIDUAL CURRENT MONITOR, 6MA DC |
320 |
|
|
- | Module, Single Pass Through | Tray | Active | DC | Current Sensor | 6mA | 1 | - | - | 50Hz/60Hz | - | - | 10.8V ~ 13.2V | - | 14.5mA | -40°C ~ 85°C | - | - | - | Through Hole | - |
|
RCM14-03_SYS_HRCM14-03 SYSTEM, CONSISTS OF 901 |
560 |
|
|
- | Module, Single Pass Through | Tray | Active | DC | Current Sensor | 6mA | 1 | - | - | 50Hz/60Hz | - | - | 10.8V ~ 13.2V | - | 14.5mA | -40°C ~ 85°C | - | - | - | Through Hole | - |
|
RCM14-01_SYS_HRCM14-01 SYSTEM, CONSISTS OF 901 |
560 |
|
|
- | Module, Single Pass Through | Tray | Active | DC | Current Sensor | 6mA | 1 | - | - | 50Hz/60Hz | - | - | 10.8V ~ 13.2V | - | 14.5mA | -40°C ~ 85°C | - | - | - | Chassis Mount | - |
|
RCM14-01_SYS_VRCM14-01 SYSTEM, CONSISTS OF 901 |
560 |
|
|
- | Module, Single Pass Through | Tray | Active | DC | Current Sensor | 6mA | 1 | - | - | 50Hz/60Hz | - | - | 10.8V ~ 13.2V | - | 14.5mA | -40°C ~ 85°C | - | - | - | Chassis Mount | - |
|
RCM14-03RESIDUAL CURRENT MONITOR, 6MA DC |
155 |
|
|
- | Module, Single Pass Through | Tray | Active | DC | Current Sensor | 6mA | 1 | - | - | DC ~ 60Hz | - | - | 10.8V ~ 13.2V | - | 40mA | -40°C ~ 85°C | - | - | - | Chassis Mount | - |
|
RCM14-03_SYS_VRCM14-03 SYSTEM, CONSISTS OF 901 |
555 |
|
|
- | Module, Single Pass Through | Tray | Active | DC | Current Sensor | 6mA | 1 | - | - | DC ~ 60Hz | - | - | 10.8V ~ 13.2V | - | 40mA | -40°C ~ 85°C | - | - | - | Through Hole | - |
|
HCSP-1BS-0900AUTOMOTIVE OPEN LOOP CURRENT SEN |
106 |
|
|
- | Module | Bulk | Active | AC/DC | Hall Effect, Open Loop | 900A | 1 | Ratiometric, Voltage | 2.22mV/A | 70kHz ~ 250kHz | - | - | 4.5V ~ 5.5V | 3µs | 14mA | -40°C ~ 125°C | - | - | Bidirectional | Chassis Mount | - |
|
RCM20-03RESIDUAL CURRENT MONITOR, 6MA DC |
185 |
|
|
- | Module, Single Pass Through | Tray | Active | DC | Current Sensor | 6mA | 1 | - | - | 50Hz/60Hz | - | - | 10.8V ~ 13.2V | - | 14.5mA | -40°C ~ 85°C | - | - | - | Chassis Mount | - |
|
RCM20-01RESIDUAL CURRENT MONITOR, 6MA DC |
182 |
|
|
- | Module, Single Pass Through | Tray | Active | DC | Current Sensor | 6mA | 1 | - | - | 50Hz/60Hz | - | - | 12V ~ 24V | - | 13mA | -40°C ~ 85°C | - | - | - | Chassis Mount | - |
|
HAH3DR 800-S0ETRANSDUCER |
69 |
|
|
HAH3DR | Module | Bulk | Active | AC/DC | Hall Effect, Open Loop | 800A | 1 | Ratiometric, Voltage | 2.5mV/A | DC ~ 40kHz | ±1% | ±3.5% | 4.75V ~ 5.25V | 6µs | 60mA | -40°C ~ 125°C | - | - | Unidirectional | Chassis Mount | - |
|
CSNV500M-125CSNV500 SERIES HALL-BASED CLOSED |
56 |
|
|
CSNV500 | Module | Box | Active | AC/DC | Hall Effect, Closed Loop | 25A | 3 | CAN Bus | - | DC ~ 200kHz | ±0.1% | ±0.24% | 4.75V ~ 5.25V | 200ns | 12mA | -40°C ~ 85°C | - | - | Unidirectional | Through Hole | - |
|
CSNV500M-124CSNV500 SERIES HALL-BASED CLOSED |
54 |
|
|
CSNV500 | Module | Box | Active | AC/DC | Hall Effect, Closed Loop | 25A | 3 | CAN Bus | - | DC ~ 200kHz | ±0.1% | ±0.24% | 4.75V ~ 5.25V | 200ns | 12mA | -40°C ~ 85°C | - | - | Unidirectional | Through Hole | - |
|
CSNV500N-154CSNV500 SERIES HALL-BASED CLOSED |
36 |
|
|
CSNV500 | Module | Box | Active | AC/DC | Hall Effect, Closed Loop | 25A | 3 | CAN Bus | - | DC ~ 200kHz | ±0.1% | ±0.24% | 4.75V ~ 5.25V | 200ns | 12mA | -40°C ~ 85°C | - | - | Unidirectional | Through Hole | - |
|
CSNV500M-354MCSNV500 SERIES HALL-BASED CLOSED |
40 |
|
|
CSNV500 | Module, Single Pass Through | Box | Active | AC/DC | Hall Effect, Closed Loop | 500A | 1 | CAN Bus | - | - | ±0.1% | ±0.5% | 7V ~ 18V | - | 250mA | -40°C ~ 85°C | - | - | Bidirectional | Chassis Mount | - |
|
RCM14-04_SYSRCM14-04 SYSTEM, CONSISTS OF 901 |
547 |
|
|
- | Module, Single Pass Through | Tray | Active | DC | Current Sensor | 56mA | 1 | - | - | DC ~ 60Hz | - | - | 12V ~ 24V | - | 25mA | -40°C ~ 85°C | - | - | - | Through Hole | - |
|
RC05-150-1000-STRANSF CURR SENSE 150MV/KA 50HZ |
48 |
|
|
RC05-SSSS-LLLL-O | Module, Single Pass Through | Tray | Active | AC/DC | Rogowski Coil | 8000A | 1 | - | 0.15mV/A | 50kHz | - | - | - | - | - | -20°C ~ 80°C | - | - | - | Free Hanging | - |
|
HAC 200-SSENSOR CURRENT HALL 200A AC/DC |
40 |
|
|
HAC | Module | Bulk | Not For New Designs | AC/DC | Hall Effect, Open Loop | 200A | 1 | Ratiometric, Voltage | - | DC ~ 50kHz | ±1% | ±1% | ±15V | 7µs | 18mA | -10°C ~ 80°C | - | - | Bidirectional | Chassis Mount | - |
Category Overview
Current Sensors Products & Selection Guide
Current Sensors are widely used in industrial automation, automotive electronics, communication equipment, consumer electronics, new energy systems, and many other electronic applications. We offer products from multiple manufacturers, packages, and specifications to help engineers and buyers compare and source suitable components.
Use the manufacturer, key specification, availability, and Datasheet filters to narrow down the right Current Sensors. If the exact part is not listed, submit an inquiry and our team can help check stock, lead time, and suitable alternatives.
FAQ
How do I choose the right Current Sensors?
Start with the required electrical specifications, package, operating temperature, application conditions, and manufacturer preference, then compare availability and lead time.
Can I order based on the stock shown on this page?
Inventory can change with supply conditions. For project or volume requirements, please submit an inquiry so current stock, pricing, and lead time can be confirmed.
What if the exact part number I need is not listed?
Send us the part number and required quantity. We can help source hard-to-find parts and suggest suitable alternatives based on key specifications.
Do you provide Datasheets and technical documents?
Yes. Use the Datasheet links in the product list to view available technical documents. If a document is unavailable, contact us and we can help check it.