| Photo | Mfr. Part # | Availability | Quantity | Datasheet | Series | Package/Case | Packaging | Product Status | For Measuring | Sensor Type | Current - Sensing | Number of Channels | Output | Sensitivity | Frequency | Linearity | Accuracy | Voltage - Supply | Response Time | Current - Supply (Max) | Operating Temperature | Grade | Qualification | Polarization | Mounting Type | Supplier Device Package |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
HO 60-NP-0100SENSOR CURRENT HALL 60A AC/DC |
879 |
|
|
HO-NP | Module | Tray | Active | AC/DC | Hall Effect, Open Loop | 60A | 1 | Ratiometric, Voltage | - | DC ~ 350kHz | ±0.5% | ±1.4% | 5V | 2.5µs | 25mA | -40°C ~ 105°C | - | - | Bidirectional | Through Hole | - |
|
|
F02P050S05LSENSOR |
400 |
|
|
F02P | Module | Tray | Active | AC | Flux Gate, Closed Loop | 50A | 1 | Ratiometric, Voltage | 12.5mV/A | 300kHz | ±1% | ±0.9% | 5V | 0.3µs | 55mA | -40°C ~ 105°C | - | - | Bidirectional | Through Hole | - |
|
L01Z300S05SENSOR CURRENT HALL 300A AC/DC |
152 |
|
|
- | Module | Bulk | Active | AC/DC | Hall Effect, Open Loop | 300A | 1 | Ratiometric, Voltage | - | DC ~ 100kHz | ±1% | - | 5V | 10µs | 15mA | -10°C ~ 80°C | - | - | Bidirectional | Through Hole | - |
|
LKSR 6-NPSENSOR CURRENT HALL 6A UNIPOLAR |
383 |
|
|
LKSR | Module | Tray | Active | AC/DC | Hall Effect, Closed Loop | 6A | 1 | Ratiometric, Voltage | 104.2mV/A | 300kHz | ±0.1% | ±1.25% | 4.75V ~ 5.25V | 400ns | 23mA | -40°C ~ 105°C | - | - | Bidirectional | Through Hole | - |
|
LKSR 15-NPSENSOR CURRENT HALL 15A UNIPOLAR |
373 |
|
|
LKSR | Module | Tray | Active | AC/DC | Hall Effect, Closed Loop | 15A | 1 | Ratiometric, Voltage | 41.67mV/A | 300kHz | ±0.1% | ±1.25% | 4.75V ~ 5.25V | 400ns | 27.5mA | -40°C ~ 105°C | - | - | Bidirectional | Through Hole | - |
|
LPSR 15-NPSENSOR CURRENT HALL 15A UNIPOLAR |
236 |
|
|
LPSR | Module | Tray | Active | AC/DC | Hall Effect, Closed Loop | 15A | 1 | Ratiometric, Voltage | 41.67mV/A | 300kHz | ±0.1% | ±1.25% | 4.75V ~ 5.25V | 400ns | 27.5mA | -40°C ~ 105°C | - | - | Bidirectional | Through Hole | - |
|
LPSR 6-NPSENSOR CURRENT HALL 6A UNIPOLAR |
173 |
|
|
LPSR | Module | Tray | Active | AC/DC | Hall Effect, Closed Loop | 6A | 1 | Ratiometric, Voltage | 104.2mV/A | 300kHz | ±0.1% | ±1.25% | 4.75V ~ 5.25V | 400ns | 23mA | -40°C ~ 105°C | - | - | Bidirectional | Through Hole | - |
|
HX 25-PSENSOR CURRENT HALL 25A AC/DC |
300 |
|
|
HX | Module | Bulk | Not For New Designs | AC/DC | Hall Effect, Open Loop | 25A | 1 | Ratiometric, Voltage | - | 50kHz | ±1% | ±1% | ±15V | 3µs | 15mA | -25°C ~ 85°C | - | - | Bidirectional | Through Hole | - |
|
LES 50-NPSENSOR CURRENT HALL 50A UNIPOLAR |
164 |
|
|
LES | Module | Tray | Active | AC/DC | Hall Effect, Closed Loop | 50A | 1 | Ratiometric, Voltage | 12.5mV/A | 300kHz | ±0.1% | ±2.25% | 4.75V ~ 5.25V | 400ns | 45mA | -40°C ~ 105°C | - | - | Bidirectional | Through Hole | - |
|
LPSR 50-NPSENSOR CURRENT HALL 50A UNIPOLAR |
198 |
|
|
LPSR | Module | Tray | Active | AC/DC | Hall Effect, Closed Loop | 50A | 1 | Ratiometric, Voltage | 12.5mV/A | 300kHz | ±0.1% | ±1.25% | 4.75V ~ 5.25V | 400ns | 51.3mA | -40°C ~ 105°C | - | - | Bidirectional | Through Hole | - |
|
HOB 75-P1 MHZ OPEN-LOOP CURRENT SENSOR 7 |
297 |
|
|
HOB-P | Module | Bulk | Active | AC/DC | Open Loop | 75A | 1 | Voltage | 10.667mV/A | 1MHz | ±0.6% | - | 4.6V ~ 5.5V | 200ns | 26mA | -40°C ~ 105°C | - | - | Bidirectional | Through Hole | - |
|
HOB 100-P/SP331 MHZ OPEN-LOOP CURRENT SENSOR 1 |
139 |
|
|
HOB-P/SP33 | Module | Bulk | Active | AC/DC | Open Loop | 100A | 1 | Voltage | 4.6mV/A | 1MHz | ±0.5% | - | 3.14V ~ 3.46V | - | 24mA | -40°C ~ 105°C | - | - | Bidirectional | Through Hole | - |
|
HOB 130-P/SP11 MHZ OPEN-LOOP CURRENT SENSOR 1 |
119 |
|
|
HOB-P/SP1 | Module | Bulk | Active | AC/DC | Open Loop | 130A | 1 | Voltage | 16mV/A | 1MHz | ±0.45% | - | 4.6V ~ 5.5V | - | 26mA | -40°C ~ 105°C | - | - | Bidirectional | Through Hole | - |
|
HOB 100-P1 MHZ OPEN-LOOP CURRENT SENSOR 1 |
106 |
|
|
HOB-P | Module | Bulk | Active | AC/DC | Open Loop | 100A | 1 | Voltage | 8mV/A | 1MHz | ±0.5% | - | 4.6V ~ 5.5V | 200ns | 26mA | -40°C ~ 105°C | - | - | Bidirectional | Through Hole | - |
|
LA37S400S05KMCURRENT SENSOR (400A; 5V) -40 10 |
199 |
|
|
LA37S S05K | Module, Single Pass Through | Tray | Active | DC | Open Loop | 400A | 1 | Analog Voltage | 1.563mV/A | 100kHz | ±0.5% | ±1.8% | 4.5V ~ 5.5V | 3.5µs | 23mA | -40°C ~ 105°C | - | - | - | Chassis Mount | - |
|
LA37S500S05KMCURRENT SENSOR (500A; 5V) -40 10 |
190 |
|
|
LA37S S05K | Module, Single Pass Through | Tray | Active | DC | Open Loop | 500A | 1 | Analog Voltage | 1.25mV/A | 100kHz | ±0.5% | ±1.8% | 4.5V ~ 5.5V | 3.5µs | 23mA | -40°C ~ 105°C | - | - | - | Chassis Mount | - |
|
LA37S200S05KMCURRENT SENSOR (200A; 5V) -40 10 |
164 |
|
|
LA37S S05K | Module, Single Pass Through | Tray | Active | DC | Open Loop | 200A | 1 | Analog Voltage | 3.125mV/A | 100kHz | ±0.5% | ±1.8% | 4.5V ~ 5.5V | 3.5µs | 23mA | -40°C ~ 105°C | - | - | - | Chassis Mount | - |
|
RCM SYSTEM CT VERTICALRCM14 SYSTEM CURRENT TRANSFORMER |
600 |
|
|
- | - | Tray | Active | - | - | 6mA | - | - | - | - | - | - | 12V | - | - | -40°C ~ 85°C | - | - | - | Through Hole | - |
|
RCM SYSTEM CT HORIZONTALRCM14 SYSTEM CURRENT TRANSFORMER |
350 |
|
|
- | - | Tray | Active | - | - | 6mA | - | - | - | - | - | - | 12V | - | - | -40°C ~ 85°C | - | - | - | Through Hole | - |
|
RC01-300TRANSF CURR SENSE 300MV/KA 50HZ |
134 |
|
|
RC01-SSS-O | Module, Single Pass Through | Tray | Active | AC/DC | Rogowski Coil | 200A | 1 | - | 0.3mV/A | 50kHz | - | - | - | - | - | -20°C ~ 80°C | - | - | - | Through Hole | - |
Category Overview
Current Sensors Products & Selection Guide
Current Sensors are widely used in industrial automation, automotive electronics, communication equipment, consumer electronics, new energy systems, and many other electronic applications. We offer products from multiple manufacturers, packages, and specifications to help engineers and buyers compare and source suitable components.
Use the manufacturer, key specification, availability, and Datasheet filters to narrow down the right Current Sensors. If the exact part is not listed, submit an inquiry and our team can help check stock, lead time, and suitable alternatives.
FAQ
How do I choose the right Current Sensors?
Start with the required electrical specifications, package, operating temperature, application conditions, and manufacturer preference, then compare availability and lead time.
Can I order based on the stock shown on this page?
Inventory can change with supply conditions. For project or volume requirements, please submit an inquiry so current stock, pricing, and lead time can be confirmed.
What if the exact part number I need is not listed?
Send us the part number and required quantity. We can help source hard-to-find parts and suggest suitable alternatives based on key specifications.
Do you provide Datasheets and technical documents?
Yes. Use the Datasheet links in the product list to view available technical documents. If a document is unavailable, contact us and we can help check it.