Current Sensors
| Photo | Mfr. Part # | Availability | Quantity | Datasheet | Series | Package/Case | Packaging | Product Status | For Measuring | Sensor Type | Current - Sensing | Number of Channels | Output | Sensitivity | Frequency | Linearity | Accuracy | Voltage - Supply | Response Time | Current - Supply (Max) | Operating Temperature | Grade | Qualification | Polarization | Mounting Type | Supplier Device Package |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
20310509101SENSOR CURRENT HALL 500A AC |
0 |
|
|
- | Module, Single Pass Through | Bulk | Obsolete | AC/DC | Hall Effect, Closed Loop | 500A | 1 | Ratiometric, Voltage | - | - | ±0.1% | ±1% | 15V ~ 24V | 1µs | 35mA | -40°C ~ 85°C | - | - | Bidirectional | Chassis Mount | - |
|
IVT-S-2K5-U0-I-CAN2-12/24CURRENT SENSOR - ISA-SCALE IVT-S |
0 |
|
|
IVT-S | Module | Tray | Active | DC | Shunt | 2500A | - | - | - | - | 0.01% | ±0.4% | 5.5V ~ 40V | - | 80mA | -40°C ~ 105°C | - | - | Bidirectional | Chassis Mount | - |
|
LTC 600-TTRANSDUCER |
0 |
|
|
LTC | Module | Bulk | Active | AC/DC | Hall Effect, Closed Loop | 500A | 1 | Current | - | DC ~ 100kHz | ±0.1% | ±1.6% | ±15V ~ 24V | 1µs | - | -40°C ~ 85°C | - | - | Bidirectional | Chassis Mount | - |
|
CTL2001FSENSOR CURRENT 100A, 150A, 200A |
0 |
|
|
CTL | Module, Single Pass Through | Bulk | Active | AC | Transformer w/Conditioning | 100A, 150A, 200A (Selectable) | 1 | Ratiometric, 0V ~ 10V | - | 50Hz ~ 60Hz | - | ±1% | Self Powered | 100ms | - | -20°C ~ 50°C | - | - | Bidirectional | Chassis Mount | - |
|
AK 5 B420LTRANSDUCER |
0 |
|
|
AK | Module, Single Pass Through | Bulk | Active | AC | Current Transducer | 2A, 5A (Selectable) | 1 | Current | - | 20Hz ~ 100Hz | - | ±1% | 24V | 300ms | - | -20°C ~ 50°C | - | - | Unidirectional | Chassis Mount | - |
|
CSNM191-005SENSOR CURRENT HALL 1000A AC/DC |
0 |
|
|
CSN | Module, Single Pass Through | Bulk | Obsolete | AC/DC | Hall Effect, Closed Loop | 1000A | 1 | Ratiometric, Current | - | - | - | ±0.5% | ±12V ~ 18V | 1µs | 14mA | -40°C ~ 85°C | - | - | Bidirectional | Through Hole | - |
|
LA 10-I/SP8SENSORS |
0 |
|
|
- | - | Bulk | Active | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
CR4150-75SENSOR CURRENT XFMR 75A AC |
0 |
|
|
CR4100 | Module, Dual Pass Through | Bulk | Obsolete | AC | Transformer w/Conditioning | 75A | 2 | Ratiometric, 0V ~ 5V | - | 20Hz ~ 5kHz | - | ±0.5% | 24V | 250ms | 75mA | 0°C ~ 60°C | - | - | Bidirectional | DIN Rail, Panel | - |
|
LT 1005-S/SP3TRANSDUCER |
0 |
|
|
LT | Module, Single Pass Through | Bulk | Not For New Designs | AC/DC | Hall Effect, Closed Loop | 1000A | 1 | Current | - | DC ~ 150kHz | ±0.1% | ±0.4% | ±15V | 1µs | - | -25°C ~ 70°C | - | - | Bidirectional | Chassis Mount | - |
|
LT 505-S/SP3TRANSDUCER |
0 |
|
|
LT | Module, Single Pass Through | Bulk | Not For New Designs | AC/DC | Hall Effect, Closed Loop | 500A | 1 | Current | - | DC ~ 150kHz | ±0.1% | ±0.6% | ±15V ~ 24V | 1µs | - | -10°C ~ 85°C | - | - | Bidirectional | Chassis Mount | - |
|
CRD4110-25SENSOR CURRENT XFMR 25A AC |
0 |
|
|
CRD4100 | Module | Bulk | Active | AC | Transformer w/Conditioning | 25A | 1 | RS485 | - | 20Hz ~ 5kHz | - | ±0.5% | 24V | 250ms | 30mA | 0°C ~ 60°C | - | - | Bidirectional | DIN Rail, Panel | - |
|
CRD4110-15SENSOR CURRENT XFMR 15A AC |
0 |
|
|
CRD4100 | Module | Bulk | Active | AC | Transformer w/Conditioning | 15A | 1 | RS485 | - | 20Hz ~ 5kHz | - | ±0.5% | 24V | 250ms | 30mA | 0°C ~ 60°C | - | - | Bidirectional | DIN Rail, Panel | - |
|
CRD4110-5SENSOR CURRENT XFMR 5A AC |
0 |
|
|
CRD4100 | Module | Bulk | Active | AC | Transformer w/Conditioning | 5A | 1 | RS485 | - | 20Hz ~ 5kHz | - | ±0.5% | 24V | 250ms | 30mA | 0°C ~ 60°C | - | - | Bidirectional | DIN Rail, Panel | - |
|
CRD4110-1SENSOR CURRENT XFMR 1A AC |
0 |
|
|
CRD4100 | Module | Bulk | Active | AC | Transformer w/Conditioning | 1A | 1 | RS485 | - | 20Hz ~ 5kHz | - | ±0.5% | 24V | 250ms | 30mA | 0°C ~ 60°C | - | - | Bidirectional | DIN Rail, Panel | - |
|
CR4460-0.5SENSOR CURRENT XFMR 0.5A AC |
0 |
|
|
CR4400 | Module | Bulk | Active | AC | Transformer w/Conditioning | 500mA | 2 | Ratiometric, 4mA ~ 20mA | - | 50Hz ~ 400Hz | - | ±0.5% | 24V | 250ms | 90mA | 0°C ~ 60°C | - | - | Bidirectional | DIN Rail, Panel | - |
|
PCM 30-PTRANSDUCER |
0 |
|
|
PCM | Module | Bulk | Not For New Designs | AC/DC | Hall Effect, Closed Loop | 30A | 1 | Current | - | DC ~ 1kHz | ±0.2% | ±1% | 24V | 30µs | 50mA | -25°C ~ 55°C | - | - | Unidirectional | Through Hole | - |
|
AHR 1000 B5TRANSDUCER |
0 |
|
|
AHR | Module, Single Pass Through | Bulk | Active | AC/DC | Hall Effect, Open Loop | 1000A | 1 | Analog Voltage | - | DC, 20Hz ~ 6kHz | ±1% | ±1% | 20V ~ 50V | 150ms | 35mA | -40°C ~ 70°C | - | - | Unidirectional | Chassis Mount | - |
|
AHR 1000 B10TRANSDUCER |
0 |
|
|
AHR | Module, Single Pass Through | Bulk | Active | AC/DC | Hall Effect, Open Loop | 1000A | 1 | Analog Voltage | - | DC, 20Hz ~ 6kHz | ±1% | ±1% | 20V ~ 50V | 150ms | 35mA | -40°C ~ 70°C | - | - | Unidirectional | Chassis Mount | - |
|
AHR 2000 B10TRANSDUCER |
0 |
|
|
AHR | Module, Single Pass Through | Bulk | Active | AC/DC | Hall Effect, Open Loop | 2000A | 1 | Analog Voltage | - | DC, 20Hz ~ 6kHz | ±1% | ±1% | 20V ~ 50V | 150ms | 35mA | -40°C ~ 70°C | - | - | Unidirectional | Chassis Mount | - |
|
AHR 1500 B420TRANSDUCER |
0 |
|
|
AHR | Module, Single Pass Through | Bulk | Active | AC/DC | Hall Effect, Open Loop | 1500A | 1 | Voltage | - | DC, 20Hz ~ 6kHz | ±1% | ±1% | 20V ~ 50V | 150ms | 30mA | -40°C ~ 70°C | - | - | Unidirectional | Chassis Mount | - |
Category Overview
Current Sensors Products & Selection Guide
Current Sensors are widely used in industrial automation, automotive electronics, communication equipment, consumer electronics, new energy systems, and many other electronic applications. We offer products from multiple manufacturers, packages, and specifications to help engineers and buyers compare and source suitable components.
Use the manufacturer, key specification, availability, and Datasheet filters to narrow down the right Current Sensors. If the exact part is not listed, submit an inquiry and our team can help check stock, lead time, and suitable alternatives.
FAQ
How do I choose the right Current Sensors?
Start with the required electrical specifications, package, operating temperature, application conditions, and manufacturer preference, then compare availability and lead time.
Can I order based on the stock shown on this page?
Inventory can change with supply conditions. For project or volume requirements, please submit an inquiry so current stock, pricing, and lead time can be confirmed.
What if the exact part number I need is not listed?
Send us the part number and required quantity. We can help source hard-to-find parts and suggest suitable alternatives based on key specifications.
Do you provide Datasheets and technical documents?
Yes. Use the Datasheet links in the product list to view available technical documents. If a document is unavailable, contact us and we can help check it.