| Photo | Mfr. Part # | Availability | Quantity | Datasheet | Series | Package/Case | Packaging | Product Status | For Measuring | Sensor Type | Current - Sensing | Number of Channels | Output | Sensitivity | Frequency | Linearity | Accuracy | Voltage - Supply | Response Time | Current - Supply (Max) | Operating Temperature | Grade | Qualification | Polarization | Mounting Type | Supplier Device Package |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
IVT-S-500-U0-I-CAN2-12/24CURRENT SENSOR - ISA-SCALE IVT-S |
0 |
|
|
IVT-S | Module | Tray | Active | DC | Shunt | 500A | - | - | - | - | 0.01% | ±0.4% | 5.5V ~ 40V | - | 80mA | -40°C ~ 105°C | - | - | Bidirectional | Chassis Mount | - |
|
|
20312000101SENSOR CURRENT HALL 2000A AC |
0 |
|
|
- | Module, Single Pass Through | Bulk | Obsolete | AC/DC | Hall Effect, Closed Loop | 2000A | 1 | Ratiometric, Voltage | - | 100kHz | ±0.1% | ±0.3% | 15V ~ 24V | 1µs | 33mA | -40°C ~ 85°C | - | - | Bidirectional | Panel Mount | - |
|
CR4110S-15SENSOR CURRENT XFMR 15A AC |
0 |
|
|
CR4100 | Module | Bulk | Active | AC | Transformer w/Conditioning | 15A | 1 | Ratiometric, 0V ~ 5V | - | 20Hz ~ 5kHz | - | ±0.5% | 24V | 250ms | 25mA | 0°C ~ 60°C | - | - | Bidirectional | DIN Rail, Panel | - |
|
CR4110S-10SENSOR CURRENT XFMR 10A AC |
0 |
|
|
CR4100 | Module | Bulk | Active | AC | Transformer w/Conditioning | 10A | 1 | Ratiometric, 0V ~ 5V | - | 20Hz ~ 5kHz | - | ±0.5% | 24V | 250ms | 25mA | 0°C ~ 60°C | - | - | Bidirectional | DIN Rail, Panel | - |
|
CR4110S-100SENSOR CURRENT XFMR 100A AC |
0 |
|
|
CR4100 | Module | Bulk | Active | AC | Transformer w/Conditioning | 100A | 1 | Ratiometric, 0V ~ 5V | - | 20Hz ~ 5kHz | - | ±0.5% | 24V | 250ms | 25mA | 0°C ~ 60°C | - | - | Bidirectional | DIN Rail, Panel | - |
|
CR4110S-150SENSOR CURRENT XFMR 150A AC |
0 |
|
|
CR4100 | Module | Bulk | Active | AC | Transformer w/Conditioning | 150A | 1 | Ratiometric, 0V ~ 5V | - | 20Hz ~ 5kHz | - | ±0.5% | 24V | 250ms | 25mA | 0°C ~ 60°C | - | - | Bidirectional | DIN Rail, Panel | - |
|
CR4110S-25SENSOR CURRENT XFMR 25A AC |
0 |
|
|
CR4100 | Module | Bulk | Active | AC | Transformer w/Conditioning | 25A | 1 | Ratiometric, 0V ~ 5V | - | 20Hz ~ 5kHz | - | ±0.5% | 24V | 250ms | 25mA | 0°C ~ 60°C | - | - | Bidirectional | DIN Rail, Panel | - |
|
CR4110S-30SENSOR CURRENT XFMR 30A AC |
0 |
|
|
CR4100 | Module | Bulk | Active | AC | Transformer w/Conditioning | 30A | 1 | Ratiometric, 0V ~ 5V | - | 20Hz ~ 5kHz | - | ±0.5% | 24V | 250ms | 25mA | 0°C ~ 60°C | - | - | Bidirectional | DIN Rail, Panel | - |
|
CR4110S-40SENSOR CURRENT XFMR 40A AC |
0 |
|
|
CR4100 | Module | Bulk | Active | AC | Transformer w/Conditioning | 40A | 1 | Ratiometric, 0V ~ 5V | - | 20Hz ~ 5kHz | - | ±0.5% | 24V | 250ms | 25mA | 0°C ~ 60°C | - | - | Bidirectional | DIN Rail, Panel | - |
|
CR4110S-5SENSOR CURRENT XFMR 5A AC |
0 |
|
|
CR4100 | Module | Bulk | Active | AC | Transformer w/Conditioning | 5A | 1 | Ratiometric, 0V ~ 5V | - | 20Hz ~ 5kHz | - | ±0.5% | 24V | 250ms | 25mA | 0°C ~ 60°C | - | - | Bidirectional | DIN Rail, Panel | - |
|
CR4110S-50SENSOR CURRENT XFMR 50A AC |
0 |
|
|
CR4100 | Module | Bulk | Active | AC | Transformer w/Conditioning | 50A | 1 | Ratiometric, 0V ~ 5V | - | 20Hz ~ 5kHz | - | ±0.5% | 24V | 250ms | 25mA | 0°C ~ 60°C | - | - | Bidirectional | DIN Rail, Panel | - |
|
CR4110S-75SENSOR CURRENT XFMR 75A AC |
0 |
|
|
CR4100 | Module | Bulk | Active | AC | Transformer w/Conditioning | 75A | 1 | Ratiometric, 0V ~ 5V | - | 20Hz ~ 5kHz | - | ±0.5% | 24V | 250ms | 25mA | 0°C ~ 60°C | - | - | Bidirectional | DIN Rail, Panel | - |
|
CR5210S-40SENSOR CURRENT HALL 40A DC |
0 |
|
|
CR5200 | Module | Bulk | Active | DC | Hall Effect, Closed Loop | 40A | 1 | Ratiometric, Voltage | - | DC | - | ±1% | 24V | 250ms | 35mA | 0°C ~ 50°C | - | - | Unidirectional | DIN Rail, Panel | - |
|
CR5220S-40SENSOR CURRENT HALL 40A DC |
0 |
|
|
CR5200 | Module | Bulk | Active | DC | Hall Effect, Closed Loop | 40A | 1 | Ratiometric, 4mA ~ 20mA | - | DC | - | ±1% | 24V | 250ms | 50mA | 0°C ~ 50°C | - | - | Unidirectional | DIN Rail, Panel | - |
|
PCM 20-P/SP2TRANSDUCER |
0 |
|
|
PCM | Module, Single Pass Through | Bulk | Not For New Designs | AC/DC | Hall Effect, Closed Loop | 20A | 1 | Current | - | DC | - | ±1% | 24V | - | - | -25°C ~ 55°C | - | - | Bidirectional | Chassis Mount | - |
|
PCM 10-P/SP1TRANSDUCER |
0 |
|
|
PCM | Module | Bulk | Not For New Designs | AC/DC | Hall Effect, Closed Loop | 10A | 1 | Current | - | DC to 1kHz | ±0.2% | ±1% | 24V | 10µs | 50mA | -40°C ~ 85°C | - | - | Unidirectional | Chassis Mount | - |
|
LA 305-S/SP19SENSORS |
0 |
|
|
LA | Module, Single Pass Through | Bulk | Not For New Designs | AC/DC | Hall Effect, Closed Loop | 500A | 1 | Current | - | DC ~ 100kHz | ±1% | ±0.8% | ±15V ~ 24V | 500ns | - | -40°C ~ 85°C | - | - | Bidirectional | Chassis Mount | - |
|
LF 2010-S/SPA6TRANSDUCER |
0 |
|
|
LF | Module, Single Pass Through | Bulk | Active | AC/DC | Closed Loop | 2000A | 1 | Current | 0.2mA/A | DC ~ 150kHz | ±0.1% | ±0.3% | ±14.25V ~ 25.2V | 500ns | 48mA | -40°C ~ 85°C | - | - | Bidirectional | Chassis Mount | - |
|
CR4480-20SENSOR CURRENT XFMR 20A AC |
0 |
|
|
CR4400 | Module | Bulk | Active | AC | Transformer w/Conditioning | 20A | 3 | Ratiometric, 4mA ~ 20mA | - | 50Hz ~ 400Hz | - | ±0.5% | 24V | 250ms | 120mA | 0°C ~ 60°C | - | - | Bidirectional | DIN Rail, Panel | - |
|
CR4480-30SENSOR CURRENT XFMR 30A AC |
0 |
|
|
CR4400 | Module | Bulk | Active | AC | Transformer w/Conditioning | 30A | 3 | Ratiometric, 4mA ~ 20mA | - | 50Hz ~ 400Hz | - | ±0.5% | 24V | 250ms | 120mA | 0°C ~ 60°C | - | - | Bidirectional | DIN Rail, Panel | - |
Category Overview
Current Sensors Products & Selection Guide
Current Sensors are widely used in industrial automation, automotive electronics, communication equipment, consumer electronics, new energy systems, and many other electronic applications. We offer products from multiple manufacturers, packages, and specifications to help engineers and buyers compare and source suitable components.
Use the manufacturer, key specification, availability, and Datasheet filters to narrow down the right Current Sensors. If the exact part is not listed, submit an inquiry and our team can help check stock, lead time, and suitable alternatives.
FAQ
How do I choose the right Current Sensors?
Start with the required electrical specifications, package, operating temperature, application conditions, and manufacturer preference, then compare availability and lead time.
Can I order based on the stock shown on this page?
Inventory can change with supply conditions. For project or volume requirements, please submit an inquiry so current stock, pricing, and lead time can be confirmed.
What if the exact part number I need is not listed?
Send us the part number and required quantity. We can help source hard-to-find parts and suggest suitable alternatives based on key specifications.
Do you provide Datasheets and technical documents?
Yes. Use the Datasheet links in the product list to view available technical documents. If a document is unavailable, contact us and we can help check it.