Current Sensors
| Photo | Mfr. Part # | Availability | Quantity | Datasheet | Series | Package/Case | Packaging | Product Status | For Measuring | Sensor Type | Current - Sensing | Number of Channels | Output | Sensitivity | Frequency | Linearity | Accuracy | Voltage - Supply | Response Time | Current - Supply (Max) | Operating Temperature | Grade | Qualification | Polarization | Mounting Type | Supplier Device Package |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
AI-P1ATRANSDUCER |
0 |
|
|
AI | Module | Bulk | Active | AC | Rogowski Coil | 5000A | 1 | Current | 22.5mV/kA | 10Hz ~ 1.5kHz | ±1% | ±0.5% | 16.8V ~ 31.2V | - | 350mA | -25°C ~ 70°C | - | - | Unidirectional | DIN Rail | - |
|
CR4460-30SENSOR CURRENT XFMR 30A AC |
0 |
|
|
CR4400 | Module | Bulk | Active | AC | Transformer w/Conditioning | 30A | 2 | Ratiometric, 4mA ~ 20mA | - | 50Hz ~ 400Hz | - | ±0.5% | 24V | 250ms | 90mA | 0°C ~ 60°C | - | - | Bidirectional | DIN Rail, Panel | - |
|
CR4460-20SENSOR CURRENT XFMR 20A AC |
0 |
|
|
CR4400 | Module | Bulk | Active | AC | Transformer w/Conditioning | 20A | 2 | Ratiometric, 4mA ~ 20mA | - | 50Hz ~ 400Hz | - | ±0.5% | 24V | 250ms | 90mA | 0°C ~ 60°C | - | - | Bidirectional | DIN Rail, Panel | - |
|
CR4460-10SENSOR CURRENT XFMR 10A AC |
0 |
|
|
CR4400 | Module | Bulk | Active | AC | Transformer w/Conditioning | 10A | 2 | Ratiometric, 4mA ~ 20mA | - | 50Hz ~ 400Hz | - | ±0.5% | 24V | 250ms | 90mA | 0°C ~ 60°C | - | - | Bidirectional | DIN Rail, Panel | - |
|
CR4460-15SENSOR CURRENT XFMR 15A AC |
0 |
|
|
CR4400 | Module | Bulk | Active | AC | Transformer w/Conditioning | 15A | 2 | Ratiometric, 4mA ~ 20mA | - | 50Hz ~ 400Hz | - | ±0.5% | 24V | 250ms | 90mA | 0°C ~ 60°C | - | - | Bidirectional | DIN Rail, Panel | - |
|
CR4460-5SENSOR CURRENT XFMR 5A AC |
0 |
|
|
CR4400 | Module | Bulk | Active | AC | Transformer w/Conditioning | 5A | 2 | Ratiometric, 4mA ~ 20mA | - | 50Hz ~ 400Hz | - | ±0.5% | 24V | 250ms | 90mA | 0°C ~ 60°C | - | - | Bidirectional | DIN Rail, Panel | - |
|
CR4460-25SENSOR CURRENT XFMR 25A AC |
0 |
|
|
CR4400 | Module | Bulk | Active | AC | Transformer w/Conditioning | 25A | 2 | Ratiometric, 4mA ~ 20mA | - | 50Hz ~ 400Hz | - | ±0.5% | 24V | 250ms | 90mA | 0°C ~ 60°C | - | - | Bidirectional | DIN Rail, Panel | - |
|
LF 1005-S/SP13TRANSDUCER |
0 |
|
|
LF | Module, Single Pass Through | Bulk | Not For New Designs | AC/DC | Hall Effect, Closed Loop | 1000A | 1 | Current | - | DC ~ 150kHz | ±0.1% | ±0.4% | ±15V ~ 24V | 1µs | - | -40°C ~ 85°C | - | - | Bidirectional | Chassis Mount | - |
|
LF 1005-S/SP1TRANSDUCER |
0 |
|
|
LF | Module, Single Pass Through | Bulk | Not For New Designs | AC/DC | Hall Effect, Closed Loop | 500A | 1 | Current | - | DC ~ 150kHz | ±0.1% | ±0.6% | ±12V ~ 18V | 1µs | - | -10°C ~ 70°C | - | - | Bidirectional | Chassis Mount | - |
|
CR4260-0.5SENSOR CURRENT XFMR 0.5A AC |
0 |
|
|
CR4200 | Module | Bulk | Active | AC | Transformer w/Conditioning | 500mA | 2 | Ratiometric, 4mA ~ 20mA | - | 50Hz ~ 400Hz | - | ±0.5% | 24V | 250ms | - | 0°C ~ 60°C | - | - | Bidirectional | DIN Rail, Panel | - |
|
CR4220S-100SENSOR CURRENT XFMR 100A AC |
0 |
|
|
CR4200 | Module | Bulk | Active | AC | Transformer w/Conditioning | 100A | 1 | Ratiometric, 4mA ~ 20mA | - | 50Hz ~ 400Hz | - | ±0.5% | 24V | 250ms | - | 0°C ~ 60°C | - | - | Bidirectional | DIN Rail | - |
|
ICD-A-300-CAN2-12CURRENT SENSOR - ISA-SCALE DC CO |
0 |
|
|
ICD | Module | Tray | Active | DC | Shunt | 300A | 1 | - | - | - | ±0.1% | ±0.8% | 5.5V ~ 26V | - | 50mA | -40°C ~ 105°C | Automotive | - | Bidirectional | Chassis Mount | - |
|
CTSG0000SENSOR CURRENT SWITCH 250A AC |
0 |
|
|
CTS | Module, Single Pass Through | Bulk | Active | AC | Current Switch | 250A | 1 | SSR | - | 6Hz ~ 100Hz | - | - | Self Powered | 120ms | 150mA | -50°C ~ 65°C | - | - | Bidirectional | Chassis Mount | - |
|
SRCN-C290-410 CHANNELS AC CURRENT SENSOR RS |
0 |
|
|
SRCN | Module | Bag | Active | AC/DC | Current Sensor | 50A | 10 | RS485 | - | - | - | ±2.5% | 23.5V ~ 24.5V | - | 60mA | 0°C ~ 65°C | - | - | Bidirectional | DIN Rail | - |
|
ENCORE (3A)TRANSDUCER CURRENT SENS SHUNT 3A |
0 |
|
|
Encore | Module, Single Pass Through | Box | Active | - | Current Transducer | 3A | 1 | Open Collector | - | 40kHz | - | ±0.2% | - | - | - | -25°C ~ 70°C | - | - | - | Free Hanging | - |
|
ARU-B100-D300/SP3SENSOR |
0 |
|
|
ARU | Module | Bulk | Active | AC | Rogowski Coil | 1000A | 1 | Voltage | 0.1mV/A | 346kHz | - | ±0.5% | - | - | - | -40°C ~ 80°C | - | - | Unidirectional | Chassis Mount | - |
|
LTC 500-TTRANSDUCER |
0 |
|
|
LTC | Module, Single Pass Through | Bulk | Active | AC/DC | Hall Effect, Closed Loop | 500A | 1 | Current | - | DC ~ 100kHz | ±0.1% | ±0.6% | ±15V ~ 24V | 1µs | - | -40°C ~ 85°C | - | - | Bidirectional | Chassis Mount | - |
|
LT 505-STRANSDUCER |
0 |
|
|
LT | Module, Single Pass Through | Bulk | Not For New Designs | AC/DC | Current Transducer | 500A | 1 | - | - | DC ~ 150kHz | ±0.1% | ±0.6% | 15V ~ 24V | 1µs | 30mA | -10°C ~ 85°C | - | - | Bidirectional | Chassis Mount | - |
|
LTC 600-SFC/SP14TRANSDUCER |
0 |
|
|
LTC | Module, Single Pass Through | Bulk | Active | AC/DC | Hall Effect, Closed Loop | 500A | 1 | Current | - | DC ~ 100kHz | ±0.1% | ±1.6% | ±15V ~ 24V | 1µs | - | -40°C ~ 105°C | - | - | Bidirectional | Chassis Mount | - |
|
CR4420S-40SENSOR CURRENT XFMR 40A AC |
0 |
|
|
CR4400 | Module | Bulk | Active | AC | Transformer w/Conditioning | 40A | 1 | Ratiometric, 4mA ~ 20mA | - | 50Hz ~ 400Hz | - | ±0.5% | 24V | 250ms | 45mA | 0°C ~ 60°C | - | - | Bidirectional | DIN Rail, Panel | - |
Category Overview
Current Sensors Products & Selection Guide
Current Sensors are widely used in industrial automation, automotive electronics, communication equipment, consumer electronics, new energy systems, and many other electronic applications. We offer products from multiple manufacturers, packages, and specifications to help engineers and buyers compare and source suitable components.
Use the manufacturer, key specification, availability, and Datasheet filters to narrow down the right Current Sensors. If the exact part is not listed, submit an inquiry and our team can help check stock, lead time, and suitable alternatives.
FAQ
How do I choose the right Current Sensors?
Start with the required electrical specifications, package, operating temperature, application conditions, and manufacturer preference, then compare availability and lead time.
Can I order based on the stock shown on this page?
Inventory can change with supply conditions. For project or volume requirements, please submit an inquiry so current stock, pricing, and lead time can be confirmed.
What if the exact part number I need is not listed?
Send us the part number and required quantity. We can help source hard-to-find parts and suggest suitable alternatives based on key specifications.
Do you provide Datasheets and technical documents?
Yes. Use the Datasheet links in the product list to view available technical documents. If a document is unavailable, contact us and we can help check it.
