Current Sensors
| Photo | Mfr. Part # | Availability | Quantity | Datasheet | Series | Package/Case | Packaging | Product Status | For Measuring | Sensor Type | Current - Sensing | Number of Channels | Output | Sensitivity | Frequency | Linearity | Accuracy | Voltage - Supply | Response Time | Current - Supply (Max) | Operating Temperature | Grade | Qualification | Polarization | Mounting Type | Supplier Device Package |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
ADEU-S013A-L868EUMONITOR POWER CONSUMPTION OF PRO |
0 |
|
|
- | - | Bulk | Active | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
S15S-R500-MQROGOWSKI CURRENT SENSOR 500A |
0 |
|
|
S15S | Module | Box | Active | AC/DC | Rogowski Coil | 500A | 1 | Modbus | - | 1Hz ~ 1MHz | - | ±5% | 10V ~ 30V | - | 50mA | -30°C ~ 70°C | - | - | Bidirectional | Chassis Mount | - |
|
ARU-B100-D175/SP4SENSOR |
0 |
|
|
ARU | Module | Bulk | Active | AC | Rogowski Coil | 1000A | 1 | Voltage | 0.1mV/A | 455kHz | - | ±0.5% | - | - | - | -40°C ~ 80°C | - | - | Unidirectional | Chassis Mount | - |
|
|
20311000101SENSOR CURRENT HALL 1000A AC |
0 |
|
|
- | Module, Single Pass Through | Bulk | Obsolete | AC/DC | Hall Effect, Closed Loop | 1000A | 1 | Ratiometric, Voltage | - | 100kHz | ±0.1% | ±0.4% | 15V ~ 24V | 1µs | 28mA | -40°C ~ 85°C | - | - | Bidirectional | Panel Mount | - |
|
A/CTA2-250Analog Current Sensor, 4-20mA, D |
1 |
|
|
- | Module | Tape & Box (TB) | Active | AC | Current Sensor | 100A, 200A, 250A (Selectable) | 1 | Ratiometric, 4mA ~ 20mA | - | 30Hz ~ 100Hz | - | ±1% | 8.5V ~ 30V | 600ms | - | -15°C ~ 40°C | - | - | Unidirectional | Chassis Mount | - |
|
LTC 600-S/SP5TRANSDUCER |
0 |
|
|
LTC | Module | Bulk | Active | AC/DC | Hall Effect, Closed Loop | 500A | 1 | Current | - | DC ~ 100kHz | ±0.1% | ±1.6% | ±15V ~ 24V | 1µs | - | -40°C ~ 85°C | - | - | Bidirectional | Chassis Mount | - |
|
LF 505-S/SP39TRANSDUCER |
0 |
|
|
LF | Module, Single Pass Through | Bulk | Not For New Designs | AC/DC | Hall Effect, Closed Loop | 500A | 1 | Current | - | DC ~ 100kHz | ±0.1% | ±0.6% | ±15V ~ 24V | 1µs | - | -10°C ~ 70°C | - | - | Bidirectional | Chassis Mount | - |
|
MNS2-9-IN-MA-020ALTA INDUSTRIAL WIRELESS 0-20 MA |
0 |
|
|
- | IoT Finished Device | - | Active | DC | Current Sensor | 20mA | - | - | - | - | - | - | 2V ~ 3.8V | - | 22.6mA | -40°C ~ 85°C | - | - | - | Chassis Mount | - |
|
ARU-B100-D250/SP3SENSOR |
0 |
|
|
ARU | Module | Bulk | Active | AC | Rogowski Coil | 1000A | 1 | Voltage | 0.1mV/A | 382kHz | - | ±0.5% | - | - | - | -40°C ~ 80°C | - | - | Unidirectional | Chassis Mount | - |
|
CR4420S-0.5SENSOR CURRENT XFMR 0.5A AC |
0 |
|
|
CR4400 | Module | Bulk | Active | AC | Transformer w/Conditioning | 500mA | 1 | Ratiometric, 4mA ~ 20mA | - | 50Hz ~ 400Hz | - | ±0.5% | 24V | 250ms | 45mA | 0°C ~ 60°C | - | - | Bidirectional | DIN Rail, Panel | - |
|
LV 25-600/SP1SENSORS |
0 |
|
|
- | - | Bulk | Not For New Designs | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
MNS2-9-W2-CM-500ALTAAC CURRENT METER - 500 AMP |
0 |
|
|
- | IoT Finished Device | Bulk | Active | AC | Current Sensor | 500A | - | - | - | 50Hz ~ 100Hz | - | ±2% | 2V ~ 3.8V | - | 22.6mA | -40°C ~ 85°C | - | - | - | Chassis Mount | - |
|
LTC 350-TTRANSDUCER |
0 |
|
|
LTC | Module | Bulk | Active | AC/DC | Hall Effect, Closed Loop | 350A | 1 | Current | - | DC ~ 100kHz | ±0.1% | ±0.3% | ±15V ~ 24V | 1µs | - | -40°C ~ 85°C | - | - | Bidirectional | Chassis Mount | - |
|
LF 1005-S/SP22TRANSDUCER |
0 |
|
|
LF | Module, Single Pass Through | Bulk | Not For New Designs | AC/DC | Hall Effect, Closed Loop | 1000A | 1 | - | - | DC ~ 150kHz | ±1% | ±0.4% | 15V ~ 24V | 1µs | 28mA | -40°C ~ 85°C | - | - | Bidirectional | Chassis Mount | - |
|
LF 1005-S/SP57TRANSDUCER |
0 |
|
|
LF | Module, Single Pass Through | Bulk | Not For New Designs | AC/DC | Hall Effect, Closed Loop | 1000A | 1 | Current | - | DC ~ 150kHz | ±0.1% | ±0.4% | ±15V ~ 24V | 1µs | - | -40°C ~ 85°C | - | - | Bidirectional | Chassis Mount | - |
|
LF 1005-S/SP31TRANSDUCER |
0 |
|
|
- | - | Bulk | Not For New Designs | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
LF 1005-S/SP25TRANSDUCER |
0 |
|
|
LF | Module, Single Pass Through | Bulk | Not For New Designs | AC/DC | Hall Effect, Closed Loop | 1000A | 1 | Current | - | DC ~ 150kHz | ±0.1% | ±0.4% | ±15V ~ 24V | 1µs | - | -40°C ~ 85°C | - | - | Bidirectional | Chassis Mount | - |
|
LTC 1000-S/SP5TRANSDUCER |
0 |
|
|
- | - | Bulk | Active | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
LTC 1000-S/SP15TRANSDUCER |
0 |
|
|
LTC | Module, Single Pass Through | Bulk | Active | AC/DC | Hall Effect, Closed Loop | 1000A | 1 | Current | - | DC ~ 100kHz | ±0.1% | ±1% | ±15V ~ 24V | 1µs | - | -40°C ~ 85°C | - | - | Bidirectional | Chassis Mount | - |
|
LTC 1000-S/SP25TRANSDUCER |
0 |
|
|
LTC | Module, Single Pass Through | Bulk | Active | AC/DC | Hall Effect, Closed Loop | 1000A | 1 | Ratiometric, Current | - | DC ~ 100kHz | ±0.1% | ±0.4% | ±15V ~ 24V | 1µs | - | -40°C ~ 85°C | - | - | Bidirectional | Chassis Mount | - |
Category Overview
Current Sensors Products & Selection Guide
Current Sensors are widely used in industrial automation, automotive electronics, communication equipment, consumer electronics, new energy systems, and many other electronic applications. We offer products from multiple manufacturers, packages, and specifications to help engineers and buyers compare and source suitable components.
Use the manufacturer, key specification, availability, and Datasheet filters to narrow down the right Current Sensors. If the exact part is not listed, submit an inquiry and our team can help check stock, lead time, and suitable alternatives.
FAQ
How do I choose the right Current Sensors?
Start with the required electrical specifications, package, operating temperature, application conditions, and manufacturer preference, then compare availability and lead time.
Can I order based on the stock shown on this page?
Inventory can change with supply conditions. For project or volume requirements, please submit an inquiry so current stock, pricing, and lead time can be confirmed.
What if the exact part number I need is not listed?
Send us the part number and required quantity. We can help source hard-to-find parts and suggest suitable alternatives based on key specifications.
Do you provide Datasheets and technical documents?
Yes. Use the Datasheet links in the product list to view available technical documents. If a document is unavailable, contact us and we can help check it.