| Photo | Mfr. Part # | Availability | Quantity | Datasheet | Series | Package/Case | Packaging | Product Status | For Measuring | Sensor Type | Current - Sensing | Number of Channels | Output | Sensitivity | Frequency | Linearity | Accuracy | Voltage - Supply | Response Time | Current - Supply (Max) | Operating Temperature | Grade | Qualification | Polarization | Mounting Type | Supplier Device Package |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
CR45-Y-MCURRENT INDICATOR, YELLOW, W/ MO |
0 |
|
|
- | - | Bag | Active | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
CR45-A-MCURRENT INDICATOR, AMBER, W/ MOU |
0 |
|
|
- | - | Bag | Active | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
CSCA0600A000B15B02SENSOR CURRENT HALL 600A AC/DC |
0 |
|
|
CSCA-A | Module | Bulk | Obsolete | AC/DC | Hall Effect, Open Loop | 600A | 1 | Ratiometric, Voltage | - | DC ~ 50kHz | ±1% | ±2% | ±15V | 3µs | 17mA | -10°C ~ 80°C | - | - | Bidirectional | Chassis Mount | - |
|
CSCA0300A000B15B02SENSOR CURRENT HALL 300A AC/DC |
0 |
|
|
CSCA-A | Module | Bulk | Obsolete | AC/DC | Hall Effect, Open Loop | 300A | 1 | Ratiometric, Voltage | - | DC ~ 50kHz | ±1% | ±2% | ±15V | 3µs | 17mA | -10°C ~ 80°C | - | - | Bidirectional | Chassis Mount | - |
|
HAS 500-S/SP58SENSORS |
0 |
|
|
HAS | Module, Single Pass Through | Bulk | Active | AC/DC | Hall Effect | 500A | 1 | Analog Voltage | - | DC ~ 50kHz | ±1% | ±1% | 15V | 3µs | 15mA | -40°C ~ 105°C | - | - | Bidirectional | Chassis Mount | - |
|
LA 55-P/SP23SENSORS |
0 |
|
|
LA | Module, Single Pass Through | Bulk | Active | AC/DC | Hall Effect, Closed Loop | 50A | 1 | Current | - | DC ~ 200kHz | ±0.15% | ±0.7% | ±12V ~ 15V | 500ns | - | -40°C ~ 85°C | - | - | Bidirectional | Through Hole | - |
|
HOYS 200-S/SP32-0100Linear IC |
0 |
|
|
- | - | Bulk | Active | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
CSCA0500A000B15B02SENSOR CURRENT HALL 500A AC/DC |
0 |
|
|
CSCA-A | Module | Bulk | Obsolete | AC/DC | Hall Effect, Open Loop | 500A | 1 | Ratiometric, Voltage | - | DC ~ 50kHz | ±1% | ±2% | ±15V | 3µs | 17mA | -10°C ~ 80°C | - | - | Bidirectional | Chassis Mount | - |
|
CSCA0400A000B15B02SENSOR CURRENT HALL 400A AC/DC |
0 |
|
|
CSCA-A | Module | Bulk | Obsolete | AC/DC | Hall Effect, Open Loop | 400A | 1 | Ratiometric, Voltage | - | DC ~ 50kHz | ±1% | ±2% | ±15V | 3µs | 17mA | -10°C ~ 80°C | - | - | Bidirectional | Chassis Mount | - |
|
CSNE151-202SENSOR CURRENT HALL 90A AC/DC |
0 |
|
|
CSN | Module, Single Pass Through | Bulk | Obsolete | AC/DC | Hall Effect, Closed Loop | 90A | 1 | Ratiometric, Current | - | DC ~ 150kHz | ±0.2% | ±0.5% | ±15V | 1µs | 10mA | 0°C ~ 70°C | - | - | Bidirectional | Through Hole | - |
|
|
CSLA1CESENSOR CURRENT HALL 75A AC/DC |
0 |
|
|
CSLA | Module, Single Pass Through | Bulk | Obsolete | AC/DC | Hall Effect, Open Loop | 75A | 1 | Ratiometric, Voltage | 39.4mV/N | - | - | - | 8V ~ 16V | 3µs | 19mA | -25°C ~ 85°C | - | - | Bidirectional | Through Hole | - |
|
CSNB131SENSOR CURRENT HALL 100A AC/DC |
0 |
|
|
CSN | Module, Single Pass Through | Bulk | Obsolete | AC/DC | Hall Effect, Closed Loop | 100A | 1 | Ratiometric, Current | - | DC ~ 150kHz | ±0.1% | ±0.5% | ±15V | 1µs | 10mA | 0°C ~ 70°C | - | - | Bidirectional | Through Hole | - |
|
CR45-WSENSOR CURRENT INDICATOR 100A AC |
0 |
|
|
CR45 | Module | Bulk | Active | AC | Current Indicator | 100A | 1 | LED | 2A | 50Hz ~ 1kHz | - | - | Self Powered | - | - | -10°C ~ 85°C | - | - | Bidirectional | Panel Mount | - |
|
ATO-75-B1I-D10TRANSDUCER |
0 |
|
|
ATO | Module, Single Pass Through | Bulk | Active | AC/DC | Current Transducer | 75A | 1 | Current | - | 500kHz | ±0.1% | ±3% | - | - | - | -30°C ~ 70°C | - | - | Unidirectional | Chassis Mount | - |
|
CS0550BLCURRENT SENSOR,OPEN LOOP,5A,+/-5 |
3 |
|
|
CSXX50BL | Module | Tray | Active | AC | Open Loop | 5A | 1 | Ratiometric, Voltage | - | DC ~ 55kHz | ±0.5% | ±4.9% | ±4.75V ~ 5.25V | 7µs | 25mA | -10°C ~ 70°C | - | - | Bidirectional | Through Hole | - |
|
HOYS 550-S/SPH00-0100Linear IC |
0 |
|
|
- | - | Bulk | Active | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
HOYS 432-S/SPH00-0100Linear IC |
0 |
|
|
- | - | Bulk | Active | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
HOYS 372-S/SPH00-0100Linear IC |
0 |
|
|
- | - | Bulk | Active | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
HOYS 520-S/SPH00-0100Linear IC |
0 |
|
|
- | - | Bulk | Active | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
HOYS 486-S/SPH00-0100Linear IC |
0 |
|
|
- | - | Bulk | Active | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
Category Overview
Current Sensors Products & Selection Guide
Current Sensors are widely used in industrial automation, automotive electronics, communication equipment, consumer electronics, new energy systems, and many other electronic applications. We offer products from multiple manufacturers, packages, and specifications to help engineers and buyers compare and source suitable components.
Use the manufacturer, key specification, availability, and Datasheet filters to narrow down the right Current Sensors. If the exact part is not listed, submit an inquiry and our team can help check stock, lead time, and suitable alternatives.
FAQ
How do I choose the right Current Sensors?
Start with the required electrical specifications, package, operating temperature, application conditions, and manufacturer preference, then compare availability and lead time.
Can I order based on the stock shown on this page?
Inventory can change with supply conditions. For project or volume requirements, please submit an inquiry so current stock, pricing, and lead time can be confirmed.
What if the exact part number I need is not listed?
Send us the part number and required quantity. We can help source hard-to-find parts and suggest suitable alternatives based on key specifications.
Do you provide Datasheets and technical documents?
Yes. Use the Datasheet links in the product list to view available technical documents. If a document is unavailable, contact us and we can help check it.