Current Sensors
| Photo | Mfr. Part # | Availability | Quantity | Datasheet | Series | Package/Case | Packaging | Product Status | For Measuring | Sensor Type | Current - Sensing | Number of Channels | Output | Sensitivity | Frequency | Linearity | Accuracy | Voltage - Supply | Response Time | Current - Supply (Max) | Operating Temperature | Grade | Qualification | Polarization | Mounting Type | Supplier Device Package |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
HSNBV-D05TRANSDUCER |
0 |
|
|
HSNBV-D05 | Module, Single Pass Through | Bulk | Active | AC/DC | Hall Effect, Open Loop | 50A, 400A (Selectable) | 1 | Ratiometric, Voltage | 5mV/A | DC ~ 1.1kHz | ±0.5% | ±3% | 4.75V ~ 5.25V | 10µs | 20mA | -40°C ~ 125°C | - | - | Unidirectional | Chassis Mount | - |
|
HSNBV-D09TRANSDUCER |
0 |
|
|
HSNBV-D09 | Module, Single Pass Through | Bulk | Active | AC/DC | Hall Effect, Open Loop | 50A, 500A (Selectable) | 1 | Ratiometric, Voltage | 4mV/A | DC ~ 1.1kHz | ±0.5% | ±3% | 4.75V ~ 5.25V | 10µs | 20mA | -40°C ~ 125°C | - | - | Unidirectional | Chassis Mount | - |
|
HSNBV-D10TRANSDUCER |
0 |
|
|
HSNBV-D10 | Module | Bulk | Active | AC/DC | Hall Effect, Open Loop | 600A | 2 | Voltage | 10mV/A | DC ~ 1.1kHz | ±0.5% | - | 4.75V ~ 5.25V | - | 20mA | -40°C ~ 125°C | - | - | Unidirectional | Chassis Mount | - |
|
HSNBV-D06TRANSDUCER |
0 |
|
|
HSNBV-D06 | Module, Single Pass Through | Bulk | Active | AC/DC | Hall Effect, Open Loop | 50A, 300A (Selectable) | 1 | Ratiometric, Voltage | 6.67mV/A | DC ~ 1.1kHz | ±0.5% | ±3% | 4.75V ~ 5.25V | 10µs | 20mA | -40°C ~ 125°C | - | - | Unidirectional | Chassis Mount | - |
|
HSNBV-D01TRANSDUCER |
0 |
|
|
- | - | Bulk | Active | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
|
L34S200D15SENSOR CURRENT HALL 200A AC/DC |
0 |
|
|
L34SXXXD15 | Module | Bulk | Obsolete | AC/DC | Hall Effect, Open Loop | 200A | 1 | Ratiometric, Voltage | - | DC ~ 50kHz | ±0.5% | - | ±15V | 5µs | 25mA | -30°C ~ 80°C | - | - | Bidirectional | Panel Mount | - |
|
|
L34S300D15SENSOR CURRENT HALL 300A AC/DC |
0 |
|
|
L34SXXXD15 | Module | Bulk | Obsolete | AC/DC | Hall Effect, Open Loop | 300A | 1 | Ratiometric, Voltage | - | DC ~ 50kHz | ±0.5% | - | ±15V | 5µs | 25mA | -30°C ~ 80°C | - | - | Bidirectional | Panel Mount | - |
|
LA 25-NP/SP43SENSORS |
0 |
|
|
- | - | Bulk | Not For New Designs | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
LAS 100-TPSENSORS |
0 |
|
|
LAS | Module | Bulk | Not For New Designs | AC/DC | Current Transducer | 100A | 1 | Analog Voltage | - | DC ~ 100kHz | ±0.7% | ±1% | 5V | 500ns | 18mA | -40°C ~ 85°C | - | - | Unidirectional | Through Hole | - |
|
|
L34S400D15SENSOR CURRENT HALL 400A AC/DC |
0 |
|
|
L34SXXXD15 | Module | Bulk | Obsolete | AC/DC | Hall Effect, Open Loop | 400A | 1 | Ratiometric, Voltage | - | DC ~ 50kHz | ±0.5% | - | ±15V | 5µs | 25mA | -30°C ~ 80°C | - | - | Bidirectional | Panel Mount | - |
|
CDSR 0.07-NPDTTRANSDUCER |
0 |
|
|
CDSR | Module | Bulk | Active | AC/DC | Hall Effect, Open Loop | 70A | 1 | Voltage | 8.79V/A | DC ~ 2kHz | - | ±1% | 3.26V ~ 3.33V | 1ms | 50mA | -40°C ~ 85°C | - | - | Bidirectional | Through Hole | - |
|
LAS 50-TP/SP4SENSORS |
0 |
|
|
LAS | Module | Bulk | Not For New Designs | AC/DC | Closed Loop | 50A | 1 | Analog Voltage | - | DC ~ 100kHz | 0.7% | ±1% | 5V | 500ns | 18mA | -40°C ~ 85°C | - | - | Unidirectional | Through Hole | - |
|
CDSR 0.07-TPDTTRANSDUCER |
0 |
|
|
CDSR | Module | Bulk | Active | AC/DC | Hall Effect, Open Loop | 70A | 1 | Voltage | 8.79V/A | DC ~ 2kHz | - | ±1% | 3.26V ~ 3.33V | 1ms | 50mA | -40°C ~ 85°C | - | - | Bidirectional | Through Hole | - |
|
CSCA0200A000B15B02SENSOR CURRENT HALL 200A AC/DC |
0 |
|
|
CSCA-A | Module | Bulk | Obsolete | AC/DC | Hall Effect, Open Loop | 200A | 1 | Ratiometric, Voltage | - | DC ~ 50kHz | ±1% | ±2% | ±15V | 3µs | 17mA | -10°C ~ 80°C | - | - | Bidirectional | Chassis Mount | - |
|
|
L34S500D15SENSOR CURRENT HALL 500A AC/DC |
0 |
|
|
L34SXXXD15 | Module | Bulk | Obsolete | AC/DC | Hall Effect, Open Loop | 500A | 1 | Ratiometric, Voltage | - | DC ~ 50kHz | ±0.5% | - | ±15V | 5µs | 25mA | -30°C ~ 80°C | - | - | Bidirectional | Panel Mount | - |
|
|
CSLA1DGSENSOR CURRENT HALL 120A AC/DC |
0 |
|
|
CSLA | Module, Single Pass Through | Bulk | Obsolete | AC/DC | Hall Effect, Open Loop | 120A | 1 | Ratiometric, Voltage | 24.6mV/N | - | - | - | 8V ~ 16V | 3µs | 19mA | -25°C ~ 85°C | - | - | Bidirectional | Through Hole | - |
|
|
L34S600D15SENSOR CURRENT HALL 600A AC/DC |
0 |
|
|
L34SXXXD15 | Module | Bulk | Obsolete | AC/DC | Hall Effect, Open Loop | 600A | 1 | Ratiometric, Voltage | - | DC ~ 50kHz | ±0.5% | - | ±15V | 5µs | 25mA | -30°C ~ 80°C | - | - | Bidirectional | Panel Mount | - |
|
HY 30-PSENSOR CURRENT HALL 30A AC/DC |
0 |
|
|
HY | Module | Tray | Obsolete | AC/DC | Hall Effect, Open Loop | 30A | 1 | Ratiometric, Voltage | - | DC ~ 50kHz | ±1% | ±1% | ±15V | 3µs | 10mA | -10°C ~ 80°C | - | - | Bidirectional | Through Hole | - |
|
CSCA0050A000B15B02SENSOR CURRENT HALL 50A AC/DC |
0 |
|
|
CSCA-A | Module | Bulk | Obsolete | AC/DC | Hall Effect, Open Loop | 50A | 1 | Ratiometric, Voltage | - | DC ~ 50kHz | ±1% | ±2% | ±15V | 3µs | 17mA | -10°C ~ 80°C | - | - | Bidirectional | Chassis Mount | - |
|
LA 100-P/SP13SENSORS |
0 |
|
|
LA | Module, Single Pass Through | Bulk | Active | AC/DC | Hall Effect, Closed Loop | 100A | 1 | Current | - | DC ~ 200kHz | ±0.15% | ±0.7% | ±12V ~ 15V | 1µs | - | -25°C ~ 70°C | - | - | Bidirectional | Through Hole | - |
Category Overview
Current Sensors Products & Selection Guide
Current Sensors are widely used in industrial automation, automotive electronics, communication equipment, consumer electronics, new energy systems, and many other electronic applications. We offer products from multiple manufacturers, packages, and specifications to help engineers and buyers compare and source suitable components.
Use the manufacturer, key specification, availability, and Datasheet filters to narrow down the right Current Sensors. If the exact part is not listed, submit an inquiry and our team can help check stock, lead time, and suitable alternatives.
FAQ
How do I choose the right Current Sensors?
Start with the required electrical specifications, package, operating temperature, application conditions, and manufacturer preference, then compare availability and lead time.
Can I order based on the stock shown on this page?
Inventory can change with supply conditions. For project or volume requirements, please submit an inquiry so current stock, pricing, and lead time can be confirmed.
What if the exact part number I need is not listed?
Send us the part number and required quantity. We can help source hard-to-find parts and suggest suitable alternatives based on key specifications.
Do you provide Datasheets and technical documents?
Yes. Use the Datasheet links in the product list to view available technical documents. If a document is unavailable, contact us and we can help check it.