Ring Connectors
| Photo | Mfr. Part # | Availability | Quantity | Datasheet | Series | Packaging | Product Status | Terminal Type | Stud/Tab Size | Thickness | Width - Outer Edges | Length - Overall | Mounting Type | Termination | Wire Gauge | Insulation | Features | Color | Contact Material | Contact Finish |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
A4/0-38RH-CBATTERY CABLE LUG, 6 AWG, 1/4" S |
10 |
|
|
Pan-Lug™ | Bulk | Active | Circular | 3/8 Stud | 0.120" (3.05mm) | 1.020" (25.91mm) | 2.390" (60.71mm) | Free Hanging (In-Line), 45° Angle | Crimp | 4/0 AWG | Non-Insulated | - | - | Copper | Electro-Tin |
|
A4/0-12RF-CCONN RING CIRC 4/0AWG #1/2 CRIMP |
1 |
|
|
Pan-Lug™ | Bulk | Active | Circular | 1/2 Stud | 0.120" (3.05mm) | 1.020" (25.91mm) | 1.650" (41.91mm) | Free Hanging (In-Line), Right Angle | Crimp | 4/0 AWG | Non-Insulated | - | - | Copper | Electro-Tin |
|
40029SCOTCHLOK ALUMINUM ONE HOLE LUG |
5 |
|
|
- | Box | Active | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
LCMA150-10-XCONN TERM RECT RING 150MM #M10 |
1 |
|
|
Pan-Lug™ | Bulk | Active | Flat Sided, Tubular (Battery Lugs) | M10 Stud | 0.175" (4.45mm) | 1.201" (30.51mm) | 2.776" (70.50mm) | Free Hanging (In-Line) | Crimp | 150mm² | Non-Insulated | - | - | Copper | Tin |
|
LCMA240-10-XCONN TERM RECT RING 240MM #M10 |
1 |
|
|
Pan-Lug™ | Bulk | Active | Flat Sided, Tubular (Battery Lugs) | M10 Stud | 0.209" (5.30mm) | 1.476" (37.49mm) | 3.406" (86.51mm) | Free Hanging (In-Line) | Crimp | 240mm² | Non-Insulated | - | - | Copper | Tin |
|
MH10-38RX-BOTTLECONN RING CIRC 10-12AWG 3/8 25PC |
1 |
|
|
Scotchlok™ | Bulk | Active | Circular | 3/8 Stud | 0.040" (1.02mm) | 0.590" (14.99mm) | 1.200" (30.48mm) | Free Hanging (In-Line) | Crimp | 10-12 AWG | Insulated with Heat Shrink | Brazed Seam | Yellow | Copper, ETP | Tin |
|
MH14-14R/SX-BOTTLECONN RING CIRC 14-16AWG 1/4 25PC |
1 |
|
|
Scotchlok™ | Bulk | Active | Circular | 1/4 Stud | 0.030" (0.76mm) | 0.470" (11.94mm) | 1.100" (27.94mm) | Free Hanging (In-Line) | Crimp | 14-16 AWG | Insulated with Heat Shrink | Brazed Seam | Blue | Copper, ETP | Tin |
|
MV10-6RX-BOTTLECONN RING CIRC 10-12AWG #6 50PC |
1 |
|
|
Scotchlok™ | Bulk | Active | Circular | 6 Stud | 0.040" (1.02mm) | 0.380" (9.65mm) | 1.030" (26.16mm) | Free Hanging (In-Line) | Crimp | 10-12 AWG | Insulated | Brazed Seam | Yellow | - | - |
|
MNG18-14R/SX-BOTTLECONN RING CIRC 18-22AWG 100PC |
1 |
|
|
Scotchlok™ | Bulk | Active | Circular | 1/4 Stud | 0.030" (0.76mm) | 0.470" (11.94mm) | 1.070" (27.18mm) | Free Hanging (In-Line) | Crimp | 18-22 AWG | Insulated | - | Red | Copper, ETP | Tin |
|
34113-4CONN RING CIRC 16-22AWG #1/4 |
12 |
|
|
Solistrand | Bulk | Obsolete | Circular | 1/4 Stud | 0.031" (0.79mm) | 0.469" (11.91mm) | 0.856" (21.74mm) | Free Hanging (In-Line) | Crimp | 16-22 AWG | Non-Insulated | Brazed Seam, Serrated Termination | - | Copper | Nickel |
|
E10-10RB-QSTRONGHOLD RING TERMINAL, NON-IN |
1 |
|
|
StrongHold™ | Bulk | Obsolete | Circular | 10 Stud | 0.040" (1.02mm) | 0.380" (9.65mm) | 0.810" (20.57mm) | Free Hanging (In-Line) | Crimp | 10-12 AWG | Non-Insulated | Butted Seam, Serrated Termination | - | Copper | Tin |
|
E10-6RB-QSTRONGHOLD RING TERMINAL, NON-IN |
22 |
|
|
StrongHold™ | Bulk | Obsolete | Circular | 6 Stud | 0.040" (1.02mm) | 0.310" (7.87mm) | 0.780" (19.81mm) | Free Hanging (In-Line) | Crimp | 10-12 AWG | Non-Insulated | Butted Seam, Serrated Termination | - | Copper | Tin |
|
YAV18T1RING TERMINAL, #6-8 STUD, 22-18A |
79 |
|
|
- | Box | Active | Circular | 6, 7, 8 Stud | - | 0.320" (8.13mm) | 0.760" (19.30mm) | Free Hanging (In-Line) | Crimp | 18-20 AWG | Non-Insulated | - | - | Copper | Electro-Tin |
|
M14-10RKCONN RING CIRC 14-16AWG #10 |
17 |
|
|
Scotchlok™ | Bulk | Active | Circular | 10 Stud | 0.030" (0.76mm) | 0.330" (8.38mm) | 0.700" (17.78mm) | Free Hanging (In-Line) | Crimp | 14-16 AWG | Non-Insulated | Brazed Seam | - | - | - |
|
PV18-4RX-CYCONN RING CIRC 18-22AWG #4 CRIMP |
90 |
|
|
Pan-Term® | Bulk | Obsolete | Circular | 4 Stud | 0.030" (0.76mm) | 0.250" (6.35mm) | 0.880" (22.35mm) | Free Hanging (In-Line) | Crimp | 18-22 AWG | Insulated | Brazed Seam, Serrated Termination | Red | Copper | Tin |
|
P10-14RHT6-DCONN RING CIRC 10-12AWG #1/4 |
1 |
|
|
Pan-Term® | Bulk | Obsolete | Circular | 1/4 Stud | 0.040" (1.02mm) | 0.530" (13.46mm) | 0.960" (24.38mm) | Free Hanging (In-Line) | Crimp | 10-12 AWG | Non-Insulated | Brazed Seam, Serrated Termination | - | Copper | Nickel |
|
P14-14R-ECONN RING CIRC 14-18AWG #1/4 |
12 |
|
|
Pan-Term® | Bulk | Obsolete | Circular | 1/4 Stud | 0.030" (0.76mm) | 0.460" (11.68mm) | 0.910" (23.11mm) | Free Hanging (In-Line) | Crimp | 14-18 AWG | Non-Insulated | Brazed Seam, Serrated Termination | - | Copper | Tin |
|
P6-10RHT6-TCONN RING D-SHAPE 6AWG #10 CRIMP |
14 |
|
|
Pan-Term® | Bulk | Obsolete | D-Shaped | 10 Stud | 0.045" (1.14mm) | 0.470" (11.94mm) | 1.210" (30.73mm) | Free Hanging (In-Line) | Crimp | 6 AWG | Non-Insulated | Brazed Seam | - | Copper | Nickel |
|
94762CONN RING CIR 4AWG #1/4 1=1PC |
2 |
|
|
Highland™ | Bulk | Obsolete | Circular | 1/4 Stud | 0.075" (1.91mm) | 0.680" (17.27mm) | 1.740" (44.20mm) | Free Hanging (In-Line) | Crimp | 4 AWG | Insulated | Brazed Seam | Yellow | Copper, ETP | Tin |
|
P6-38RHT6-ECONN RING D-SHAPE 6AWG #3/8 |
6 |
|
|
Pan-Term® | Bulk | Obsolete | D-Shaped | 3/8 Stud | 0.045" (1.14mm) | 0.620" (15.75mm) | 1.330" (33.78mm) | Free Hanging (In-Line) | Crimp | 6 AWG | Non-Insulated | Brazed Seam | - | Copper | Nickel |
Category Overview
Ring Connectors Products & Selection Guide
Ring Connectors are widely used in industrial automation, automotive electronics, communication equipment, consumer electronics, new energy systems, and many other electronic applications. We offer products from multiple manufacturers, packages, and specifications to help engineers and buyers compare and source suitable components.
Use the manufacturer, key specification, availability, and Datasheet filters to narrow down the right Ring Connectors. If the exact part is not listed, submit an inquiry and our team can help check stock, lead time, and suitable alternatives.
FAQ
How do I choose the right Ring Connectors?
Start with the required electrical specifications, package, operating temperature, application conditions, and manufacturer preference, then compare availability and lead time.
Can I order based on the stock shown on this page?
Inventory can change with supply conditions. For project or volume requirements, please submit an inquiry so current stock, pricing, and lead time can be confirmed.
What if the exact part number I need is not listed?
Send us the part number and required quantity. We can help source hard-to-find parts and suggest suitable alternatives based on key specifications.
Do you provide Datasheets and technical documents?