Single IGBTs
| Photo | Mfr. Part # | Availability | Quantity | Datasheet | Series | Package/Case | Packaging | Product Status | IGBT Type | Voltage - Collector Emitter Breakdown (Max) | Current - Collector (Ic) (Max) | Current - Collector Pulsed (Icm) | Vce(on) (Max) @ Vge, Ic | Power - Max | Switching Energy | Input Type | Gate Charge | Td (on/off) @ 25°C | Test Condition | Reverse Recovery Time (trr) | Operating Temperature | Grade | Qualification | Mounting Type | Supplier Device Package |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
IGB30N60TATMA1IGBT TRENCH 600V 60A TO263-3 |
1,960 |
|
|
TrenchStop® | TO-263-3, D2PAK (2 Leads + Tab), TO-263AB | Tape & Reel (TR) | Active | Trench | 600 V | 60 A | 90 A | 2.05V @ 15V, 30A | 187 W | 1.46mJ | Standard | 167 nC | 23ns/254ns | 400V, 30A, 10.6Ohm, 15V | - | -40°C ~ 175°C (TJ) | - | - | Surface Mount | PG-TO263-3-2 |
|
IKWH30N67PR7XKSA1IKWH30N67PR7XKSA1 |
225 |
|
|
TRENCHSTOP™ | TO-247-3 | Tube | Active | Trench Field Stop | 670 V | 71 A | 90 A | 1.75V @ 15V, 30A | 179 W | 450µJ (on), 260µJ (off) | Standard | 85 nC | 12ns/124ns | 400V, 30A, 9.8Ohm, 15V | - | -40°C ~ 175°C (TJ) | - | - | Through Hole | PG-TO247-3-32 |
|
DIW050F065IGBT, TO-247-3L, 650V, 50A, 300A |
436 |
|
|
- | TO-247-3 | Tube | Active | Trench Field Stop | 650 V | 100 A | 300 A | 2.2V @ 15V, 50A | 350 W | 3mJ (on), 1.1mJ (off) | Standard | 78 nC | 36ns/125ns | 400V, 50A, 10Ohm, 15V | 38 ns | -55°C ~ 175°C (TJ) | - | - | Through Hole | TO-247 |
|
IKB15N65EH5ATMA1IGBT TRENCH FS 650V 30A TO263-3 |
875 |
|
|
TrenchStop™ 5 | TO-263-3, D2PAK (2 Leads + Tab), TO-263AB | Tape & Reel (TR) | Active | Trench Field Stop | 650 V | 30 A | 45 A | 2.1V @ 15V, 15A | 105 W | 400µJ (on), 80µJ (off) | Standard | 38 nC | 16ns/145ns | 400V, 15A, 39Ohm, 15V | 70 ns | -40°C ~ 175°C (TJ) | - | - | Surface Mount | PG-TO263-3 |
|
IHW25N140R5LXKSA1IGBT 1400V 68A TO247-44 |
179 |
|
|
- | TO-247-3 | Tube | Active | - | 1400 V | 68 A | 75 A | 1.9V @ 15V, 25A | 246 W | -, 110µJ (off) | Standard | 150 nC | -/195ns | 25V, 25A, 2.2Ohm, 15V | - | -40°C ~ 175°C (TJ) | - | - | Through Hole | PG-TO247-44 |
|
FGI3040G2-F085CECOSPARK2 IGN-IGBT TO262 |
1,000 |
|
|
EcoSPARK® | TO-262-3 Long Leads, I2PAK, TO-262AA | Tube | Active | - | 400 V | 41 A | - | 1.25V @ 4V, 6A | 150 W | - | Logic | 21 nC | -/4.8µs | 300V, 6.5A, 1kOhm, 5V | - | -55°C ~ 175°C (TJ) | Automotive | AEC-Q101 | Surface Mount | I2PAK (TO-262) |
|
STGB30H60DLLFBAGIGBT |
650 |
|
|
HB | TO-263-3, D2PAK (2 Leads + Tab), TO-263AB | Tape & Reel (TR) | Active | Trench Field Stop | 600 V | 60 A | 120 A | 2.15V @ 5V, 30A | 260 W | 600µJ (off) | Logic | 110 nC | -/320ns | 400V, 30A, 10Ohm, 5V | - | -55°C ~ 175°C (TJ) | - | - | Surface Mount | TO-263 (D2PAK) |
|
STGWT20IH125DFIGBT TRENCH FS 1250V 40A TO3P |
581 |
|
|
- | TO-3P-3, SC-65-3 | Tube | Active | Trench Field Stop | 1250 V | 40 A | 80 A | 2.5V @ 15V, 15A | 259 W | 410µJ (off) | Standard | 68 nC | -/106ns | 600V, 15A, 10Ohm, 15V | - | -55°C ~ 175°C (TJ) | - | - | Through Hole | TO-3P |
|
RGPR20NL43HRTL430V 20A, LPDL, IGNITION IGBT FO |
995 |
|
|
- | TO-263-3, D2PAK (2 Leads + Tab), TO-263AB | Tape & Reel (TR) | Active | - | 460 V | 20 A | - | 2V @ 5V, 10A | 107 W | - | Standard | 14 nC | 170ns/1.3µs | 300V, 8A, 100Ohm, 5V | - | -40°C ~ 175°C (TJ) | - | - | Surface Mount | TO-263L |
|
IKWH40N67PR7XKSA1IKWH40N67PR7XKSA1 |
230 |
|
|
TRENCHSTOP™ | TO-247-3 | Tube | Active | Trench Field Stop | 670 V | 88 A | 120 A | - | 208 W | 660µJ (on), 400µJ (off) | Standard | 102 nC | 16ns/146ns | 400V, 40A, 9.8Ohm, 15V | - | -40°C ~ 175°C (TJ) | - | - | Through Hole | PG-TO247-3-32 |
|
IKB20N65EH5ATMA1IGBT TRENCH FS 650V 38A TO263-3 |
788 |
|
|
TrenchStop™ 5 | TO-263-3, D2PAK (2 Leads + Tab), TO-263AB | Tape & Reel (TR) | Active | Trench Field Stop | 650 V | 38 A | 60 A | 2.1V @ 15V, 20A | 125 W | 560µJ (on), 130µJ (off) | Standard | 48 nC | 19ns/160ns | 400V, 20A, 32Ohm, 15V | 80 ns | -40°C ~ 175°C (TJ) | - | - | Surface Mount | PG-TO263-3 |
|
BIDW40N65ES5IGBT TRENCH FS 650V 80A TO247 |
2,997 |
|
|
- | TO-247-3 | Tube | Active | Trench Field Stop | 650 V | 80 A | 160 A | 1.7V @ 15V, 40A | 230 W | 580µJ (on), 630µJ (off) | Standard | 107 nC | 28ns/150ns | 400V, 40A, 10Ohm, 15V | 106 ns | -40°C ~ 175°C (TJ) | - | - | Through Hole | TO-247 |
|
RGT40TS65DGC11IGBT 650V 40A 144W TO-247N |
456 |
|
|
- | TO-247-3 | Tube | Not For New Designs | Trench Field Stop | 650 V | 40 A | 60 A | 2.1V @ 15V, 20A | 144 W | - | Standard | 40 nC | 22ns/75ns | 400V, 20A, 10Ohm, 15V | 58 ns | -40°C ~ 175°C (TJ) | - | - | Through Hole | TO-247N |
|
STGFW40H65FBIGBT HB 650V 40A ISOWATT218 |
438 |
|
|
- | TO-3P-3 Full Pack | Tube | Active | Trench Field Stop | 650 V | 80 A | 160 A | 2V @ 15V, 40A | 62.5 W | 498µJ (on), 363µJ (off) | Standard | 210 nC | 40ns/142ns | 400V, 40A, 5Ohm, 15V | - | -55°C ~ 175°C (TJ) | - | - | Through Hole | TO-3PF-3 |
|
STGWA30H65DFB2DISCRETE |
420 |
|
|
- | TO-247-3 | Bulk | Active | Trench Field Stop | 650 V | 50 A | 90 A | 2.1V @ 15V, 30A | 167 W | 270µJ (on), 310µJ (off) | Standard | 90 nC | 18.4ns/71ns | 400V, 30A, 6.8Ohm, 15V | 115 ns | -55°C ~ 175°C (TJ) | - | - | Through Hole | TO-247 Long Leads |
|
IGB15N120S7ATMA1IGBT TRENCH 1200V 34A TO263-3 |
875 |
|
|
TRENCHSTOP™ | TO-263-3, D2PAK (2 Leads + Tab), TO-263AB | Tape & Reel (TR) | Active | Trench Field Stop | 1200 V | 34 A | 45 A | 2V @ 15V, 15A | 141 W | 900µJ (on), 680µJ (off) | Standard | 97 nC | 16ns/156ns | 600V, 15A, 10Ohm, 15V | - | -40°C ~ 150°C (TJ) | - | - | Surface Mount | PG-TO263-3-2 |
|
IKP30N65F5XKSA1IGBT TRENCH 650V 55A TO220-3 |
481 |
|
|
TrenchStop™ | TO-220-3 | Tube | Active | Trench | 650 V | 55 A | 90 A | 2.1V @ 15V, 30A | 188 W | 280µJ (on), 70µJ (off) | Standard | 65 nC | 19ns/170ns | 400V, 15A, 23Ohm, 15V | 55 ns | -40°C ~ 175°C (TJ) | - | - | Through Hole | PG-TO220-3 |
|
GT30J121(Q)IGBT 600V 30A 170W TO3PN |
137 |
|
|
- | TO-3P-3, SC-65-3 | Tube | Active | - | 600 V | 30 A | 60 A | 2.45V @ 15V, 30A | 170 W | 1mJ (on), 800µJ (off) | Standard | - | 90ns/300ns | 300V, 30A, 24Ohm, 15V | - | - | - | - | Through Hole | TO-3P(N) |
|
BIDW50N65TIGBT TRENCH FS 650V 100A TO247 |
2,883 |
|
|
- | TO-247-3 | Tube | Active | Trench Field Stop | 650 V | 100 A | 150 A | 2.2V @ 15V, 50A | 416 W | 3mJ (on), 1.1mJ (off) | Standard | 123 nC | 37ns/125ns | 400V, 50A, 10Ohm, 15V | 37.5 ns | -55°C ~ 150°C (TJ) | - | - | Through Hole | TO-247 |
|
IGB50N65H5ATMA1IGBT TRENCH FS 650V 80A TO263-3 |
4,990 |
|
|
TrenchStop™ 5 | TO-263-3, D2PAK (2 Leads + Tab), TO-263AB | Tape & Reel (TR) | Active | Trench Field Stop | 650 V | 80 A | 150 A | 2.1V @ 15V, 50A | 270 W | 1.59mJ (on), 750µJ (off) | Standard | 120 nC | 23ns/173ns | 400V, 50A, 12Ohm, 15V | - | -40°C ~ 175°C (TJ) | - | - | Surface Mount | PG-TO263-3 |
Category Overview
Single IGBTs Products & Selection Guide
Single IGBTs are widely used in industrial automation, automotive electronics, communication equipment, consumer electronics, new energy systems, and many other electronic applications. We offer products from multiple manufacturers, packages, and specifications to help engineers and buyers compare and source suitable components.
Use the manufacturer, key specification, availability, and Datasheet filters to narrow down the right Single IGBTs. If the exact part is not listed, submit an inquiry and our team can help check stock, lead time, and suitable alternatives.
FAQ
How do I choose the right Single IGBTs?
Start with the required electrical specifications, package, operating temperature, application conditions, and manufacturer preference, then compare availability and lead time.
Can I order based on the stock shown on this page?
Inventory can change with supply conditions. For project or volume requirements, please submit an inquiry so current stock, pricing, and lead time can be confirmed.
What if the exact part number I need is not listed?
Send us the part number and required quantity. We can help source hard-to-find parts and suggest suitable alternatives based on key specifications.
Do you provide Datasheets and technical documents?
Yes. Use the Datasheet links in the product list to view available technical documents. If a document is unavailable, contact us and we can help check it.