Fuses
| Photo | Mfr. Part # | Availability | Quantity | Datasheet | Package/Case | Series | Packaging | Product Status | Mounting Type | Fuse Type | Current Rating (Amps) | Voltage Rating - AC | Voltage Rating - DC | Response Time | Breaking Capacity @ Rated Voltage | Melting I²t | Approval Agency | Operating Temperature | Color | Size / Dimension |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
BK/SFE-7-1/2FUSE GLASS 7.5A 32VDC 7AG |
100 |
|
|
SFE | Bulk | Active | Requires Holder | Cartridge, Glass | 7.5 A | - | 32 V | Fast Blow | - | - | UL | - | - | 0.250" Dia x 0.874" L (6.35mm x 22.20mm) | |
|
0ATO015.HXGLOFUSE AUTO 15A 32VAC/VDC BLADE |
34 |
|
|
ATO® | Bulk | Active | Requires Holder | Automotive | 15 A | 32 V | 32 V | Fast Blow | - | - | CSA, SAE, UL | - | Blue | 0.750" L x 0.200" W x 0.480" H (19.05mm x 5.08mm x 12.19mm) | |
|
0ATO07.5HXGLOFUSE AUTO 7.5A 32VAC/VDC BLADE |
65 |
|
|
ATO® | Bulk | Active | Requires Holder | Automotive | 7.5 A | 32 V | 32 V | Fast Blow | - | - | CSA, SAE, UL | - | Brown | 0.750" L x 0.200" W x 0.480" H (19.05mm x 5.08mm x 12.19mm) | |
|
|
0325025.HXPFUSE CERM 25A 250VAC 125VDC 3AB |
98 |
|
|
325 | Bulk | Active | Through Hole | Cartridge, Ceramic | 25 A | 250 V | 125 V | Slow Blow | 400A AC, 600A DC | 1030.0 | CE, CSA, K-MARK, PSE, UL | -55°C ~ 125°C | - | 0.275" Dia x 1.288" L (6.99mm x 32.72mm) | |
|
|
0324030.HXPFUSE CERM 30A 250VAC 125VDC 3AB |
90 |
|
|
324 | Bulk | Active | Through Hole | Cartridge, Ceramic | 30 A | 250 V | 125 V | Fast Blow | 100A AC, 400A DC | 2490.0 | CE, K-MARK, PSE, UL | -55°C ~ 125°C | - | 0.275" Dia x 1.288" L (6.99mm x 32.72mm) | |
|
0ATO020.HXGLOFUSE AUTO 20A 32VAC/VDC BLADE |
85 |
|
|
ATO® | Bulk | Active | Requires Holder | Automotive | 20 A | 32 V | 32 V | Fast Blow | - | - | CSA, SAE, UL | - | Yellow | 0.750" L x 0.200" W x 0.480" H (19.05mm x 5.08mm x 12.19mm) | |
|
0218.032HXPFUSE GLASS 32MA 250VAC 5X20MM |
41 |
|
|
218 | Bulk | Active | Requires Holder | Cartridge, Glass | 32 mA | 250 V | - | Slow Blow | 35A | 0.00297 | CCC, CE, CSA, K-MARK, SEMKO, UL, VDE | -55°C ~ 125°C | - | 0.205" Dia x 0.787" L (5.20mm x 20.00mm) | |
|
|
20102500021PFUSE GLASS 250MA 250VAC 5X20MM |
43 |
|
|
201P | Bulk | Active | Requires Holder | Cartridge, Glass | 250 mA | 250 V | - | Medium Blow | 80A | 0.13 | cULus | -25°C ~ 70°C | - | 0.205" Dia x 0.787" L (5.20mm x 20.00mm) | |
|
0263005.HAT1LFUSE BOARD MOUNT 5A 250VAC AXIAL |
133 |
|
|
PICO® II 263 | Cut Tape (CT) | Active | Through Hole | Board Mount (Cartridge Style Excluded) | 5 A | 250 V | - | Fast Blow | 50A | 5.55 | CSA, PSE, UR | -55°C ~ 125°C | - | 0.155" Dia x 0.280" L (3.94mm x 7.11mm) | |
|
0263004.HAT1LFUSE BOARD MOUNT 4A 250VAC AXIAL |
100 |
|
|
PICO® II 263 | Cut Tape (CT) | Active | Through Hole | Board Mount (Cartridge Style Excluded) | 4 A | 250 V | - | Fast Blow | 50A | 3.08 | CSA, PSE, UR | -55°C ~ 125°C | - | 0.155" Dia x 0.280" L (3.94mm x 7.11mm) | |
|
|
0498050.HFUSE AUTO 50A 32VDC AUTO LINK |
99 |
|
|
MIDI® 498 | Bulk | Active | Bolt Mount | Automotive | 50 A | - | 32 V | Slow Blow | 1kA | 13000.0 | - | -40°C ~ 125°C | - | 1.614" L x 0.472" W x 0.315" H (41.00mm x 12.00mm x 8.00mm) | |
|
0263002.HAT1LFUSE BOARD MOUNT 2A 250VAC AXIAL |
155 |
|
|
PICO® II 263 | Cut Tape (CT) | Active | Through Hole | Board Mount (Cartridge Style Excluded) | 2 A | 250 V | - | Fast Blow | 50A | 0.74 | CSA, PSE, UR | -55°C ~ 125°C | - | 0.155" Dia x 0.280" L (3.94mm x 7.11mm) | |
|
0ACJ-3150-TEFUSE BRD MNT 3.15A 350VAC 600VDC |
55 |
|
|
0ACJ | Tape & Reel (TR) | Active | Surface Mount | Board Mount (Cartridge Style Excluded) | 3.15 A | 350 V | 600 V | Fast Blow | 100A | 3.0 | cURus | -40°C ~ 125°C | - | 0.520" L x 0.199" W x 0.199" H (13.20mm x 5.05mm x 5.05mm) | |
|
0299040.LFUSE AUTO 40A 32VDC BLADE MAX |
96 |
|
|
MAXI® | Bulk | Active | Requires Holder | Automotive | 40 A | - | 32 V | Slow Blow | 1kA | 8450.0 | DIN, ISO, SAE | -40°C ~ 125°C | Orange | 1.150" L x 0.348" W x 0.850" H (29.21mm x 8.85mm x 21.59mm) | |
|
|
0299025.LFUSE AUTO 25A 32VDC BLADE MAX |
49 |
|
|
MAXI® | Bulk | Active | Requires Holder | Automotive | 25 A | - | 32 V | Slow Blow | 1kA | 2087.0 | DIN, ISO, SAE | -40°C ~ 125°C | Gray | 1.150" L x 0.348" W x 0.850" H (29.21mm x 8.85mm x 21.59mm) | |
|
0313005.HXIDPFUSE GLASS 5A 250VAC 3AB 3AG |
97 |
|
|
313 | Bulk | Active | Requires Holder | Cartridge, Glass | 5 A | 250 V | - | Slow Blow | 200A | 140.0 | CE, CSA, KC, PSE, UL | -55°C ~ 125°C | - | 0.250" Dia x 1.250" L (6.35mm x 31.75mm) | |
|
0312.300VXPFUSE GLASS 300MA 250VAC 3AB 3AG |
32 |
|
|
312 | Bulk | Active | Requires Holder | Cartridge, Glass | 300 mA | 250 V | - | Fast Blow | 35A | 0.0689 | CE, CSA, UL | -55°C ~ 125°C | - | 0.250" Dia x 1.250" L (6.35mm x 31.75mm) | |
|
|
0498030.HFUSE AUTO 30A 32VDC AUTO LINK |
73 |
|
|
MIDI® 498 | Bulk | Active | Bolt Mount | Automotive | 30 A | - | 32 V | Slow Blow | 1kA | 4200.0 | - | -40°C ~ 125°C | - | 1.614" L x 0.472" W x 0.315" H (41.00mm x 12.00mm x 8.00mm) | |
|
0AGC004.VPFUSE GLASS 4A 32VAC/VDC 5PK CARD |
30 |
|
|
AGC | Bulk | Active | Requires Holder | Cartridge, Glass | 4 A | 32 V | 32 V | - | - | - | - | - | - | 0.250" Dia x 1.250" L (6.35mm x 31.75mm) | |
|
0263.125HAT1LFUSE BRD MNT 125MA 250VAC AXIAL |
174 |
|
|
PICO® II 263 | Cut Tape (CT) | Active | Through Hole | Board Mount (Cartridge Style Excluded) | 125 mA | 250 V | - | Fast Blow | 50A | 0.00251 | CSA, UR | -55°C ~ 125°C | - | 0.155" Dia x 0.280" L (3.94mm x 7.11mm) |
Category Overview
Fuses Products & Selection Guide
Fuses are widely used in industrial automation, automotive electronics, communication equipment, consumer electronics, new energy systems, and many other electronic applications. We offer products from multiple manufacturers, packages, and specifications to help engineers and buyers compare and source suitable components.
Use the manufacturer, key specification, availability, and Datasheet filters to narrow down the right Fuses. If the exact part is not listed, submit an inquiry and our team can help check stock, lead time, and suitable alternatives.
FAQ
How do I choose the right Fuses?
Start with the required electrical specifications, package, operating temperature, application conditions, and manufacturer preference, then compare availability and lead time.
Can I order based on the stock shown on this page?
Inventory can change with supply conditions. For project or volume requirements, please submit an inquiry so current stock, pricing, and lead time can be confirmed.
What if the exact part number I need is not listed?
Send us the part number and required quantity. We can help source hard-to-find parts and suggest suitable alternatives based on key specifications.
Do you provide Datasheets and technical documents?
Yes. Use the Datasheet links in the product list to view available technical documents. If a document is unavailable, contact us and we can help check it.
