Fuses
| Photo | Mfr. Part # | Availability | Quantity | Datasheet | Package/Case | Series | Packaging | Product Status | Mounting Type | Fuse Type | Current Rating (Amps) | Voltage Rating - AC | Voltage Rating - DC | Response Time | Breaking Capacity @ Rated Voltage | Melting I²t | Approval Agency | Operating Temperature | Color | Size / Dimension |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
|
0034.5616.11FUSE GLASS 800MA 250VAC 5X20MM |
988 |
|
|
SMD-FST | Bulk | Active | Requires Holder | Cartridge, Glass | 800 mA | 250 V | - | Slow Blow | 35A | 3.85 | cURus, VDE | -55°C ~ 125°C | - | 0.205" Dia x 0.787" L (5.20mm x 20.00mm) | |
|
|
0034.5619.11FUSE GLASS 1.6A 250VAC 5X20MM |
987 |
|
|
SMD-FST | Bulk | Active | Requires Holder | Cartridge, Glass | 1.6 A | 250 V | - | Slow Blow | 35A | 10.5 | cURus, VDE | -55°C ~ 125°C | - | 0.205" Dia x 0.787" L (5.20mm x 20.00mm) | |
|
|
0034.5613.11FUSE GLASS 400MA 250VAC 5X20MM |
956 |
|
|
SMD-FST | Bulk | Active | Requires Holder | Cartridge, Glass | 400 mA | 250 V | - | Slow Blow | 35A | 0.768 | cURus, VDE | -55°C ~ 125°C | - | 0.205" Dia x 0.787" L (5.20mm x 20.00mm) | |
|
|
0034.5623.11FUSE GLASS 4A 250VAC 5X20MM |
681 |
|
|
SMD-FST | Bulk | Active | Requires Holder | Cartridge, Glass | 4 A | 250 V | - | Slow Blow | 40A | 68.3 | cURus, VDE | -55°C ~ 125°C | - | 0.205" Dia x 0.787" L (5.20mm x 20.00mm) | |
|
|
0034.5626.11FUSE GLASS 8A 250VAC 5X20MM |
365 |
|
|
SMD-FST | Bulk | Active | Requires Holder | Cartridge, Glass | 8 A | 250 V | - | Slow Blow | 80A | 275.0 | CQC, cURus, VDE | -55°C ~ 125°C | - | 0.205" Dia x 0.787" L (5.20mm x 20.00mm) | |
|
|
0034.5629.11FUSE GLASS 16A 250VAC 5X20MM |
192 |
|
|
SMD-FST | Bulk | Active | Requires Holder | Cartridge, Glass | 16 A | 250 V | - | Slow Blow | 125A | 1638.0 | CQC, cURus | -55°C ~ 125°C | - | 0.205" Dia x 0.787" L (5.20mm x 20.00mm) | |
|
|
0034.5612.11FUSE GLASS 315MA 250VAC 5X20MM |
134 |
|
|
SMD-FST | Bulk | Active | Requires Holder | Cartridge, Glass | 315 mA | 250 V | - | Slow Blow | 35A | 0.544 | cURus, VDE | -55°C ~ 125°C | - | 0.205" Dia x 0.787" L (5.20mm x 20.00mm) | |
|
3403.0131.11FUSE BOARD MOUNT 3A 125VAC 2SMD |
1,590 |
|
|
OMT | Bulk | Active | Surface Mount | Board Mount (Cartridge Style Excluded) | 3 A | 125 V | - | Slow Blow | 100A | 12.0 | cURus | -55°C ~ 125°C | - | 0.433" L x 0.181" W x 0.154" H (11.00mm x 4.60mm x 3.90mm) | |
|
BK1/S506-1-RFUSE GLASS 1A 250VAC 5X20MM |
878 |
|
|
S506 | Bulk | Active | Requires Holder | Cartridge, Glass | 1 A | 250 V | - | Slow Blow | 35A | 6.45 | BSI, CCC, CSA, CURUS, IMQ, PSE/JET, SEMKO, VDE | - | - | 0.205" Dia x 0.787" L (5.20mm x 20.00mm) | |
|
|
3403.0010.11FUSE BRD MNT 250MA 250VAC/VDC |
496 |
|
|
OMF 250 | Bulk | Active | Surface Mount | Board Mount (Cartridge Style Excluded) | 250 mA | 250 V | 250 V | Fast Blow | 100A | 0.012 | cURus | -55°C ~ 125°C | - | 0.433" L x 0.181" W x 0.154" H (11.00mm x 4.60mm x 3.90mm) | |
|
|
3403.0018.11FUSE BRD MT 1.6A 250VAC/VDC 2SMD |
491 |
|
|
OMF 250 | Bulk | Active | Surface Mount | Board Mount (Cartridge Style Excluded) | 1.6 A | 250 V | 250 V | Fast Blow | 100A | 0.84 | cURus, VDE | -55°C ~ 125°C | - | 0.433" L x 0.181" W x 0.154" H (11.00mm x 4.60mm x 3.90mm) | |
|
3403.0123.11FUSE BOARD MOUNT 5A 125VAC 2SMD |
490 |
|
|
OMT | Bulk | Active | Surface Mount | Board Mount (Cartridge Style Excluded) | 5 A | 125 V | - | Slow Blow | 100A | 37.0 | cURus | -55°C ~ 125°C | - | 0.433" L x 0.181" W x 0.154" H (11.00mm x 4.60mm x 3.90mm) | |
|
3403.0116.11FUSE BOARD MOUNT 1A 250VAC 2SMD |
473 |
|
|
OMT | Bulk | Active | Surface Mount | Board Mount (Cartridge Style Excluded) | 1 A | 250 V | - | Slow Blow | 100A | 0.99 | cURus | -55°C ~ 125°C | - | 0.433" L x 0.181" W x 0.154" H (11.00mm x 4.60mm x 3.90mm) | |
|
|
3403.0013.11FUSE BRD MNT 500MA 250VAC/VDC |
451 |
|
|
OMF 250 | Bulk | Active | Surface Mount | Board Mount (Cartridge Style Excluded) | 500 mA | 250 V | 250 V | Fast Blow | 100A | 0.03 | cURus, VDE | -55°C ~ 125°C | - | 0.433" L x 0.181" W x 0.154" H (11.00mm x 4.60mm x 3.90mm) | |
|
|
3403.0012.11FUSE BRD MNT 400MA 250VAC/VDC |
335 |
|
|
OMF 250 | Bulk | Active | Surface Mount | Board Mount (Cartridge Style Excluded) | 400 mA | 250 V | 250 V | Fast Blow | 100A | 0.02 | cURus, VDE | -55°C ~ 125°C | - | 0.433" L x 0.181" W x 0.154" H (11.00mm x 4.60mm x 3.90mm) | |
|
SF-2410HI250T-2FUSE BRDMT 2.5A 125VAC/125DC SMD |
1,328 |
|
|
SinglFuse™ SF-2410HI-T | Tape & Reel (TR) | Active | Surface Mount | Board Mount (Cartridge Style Excluded) | 2.5 A | 125 V | 125 V | Fast Blow | 50A | 16.771 | cUL, UL | -55°C ~ 125°C | - | 0.240" L x 0.102" W x 0.102" H (6.10mm x 2.59mm x 2.59mm) | |
|
TR/3216LV1.5-RFUSE BRD MNT 1.5A 125VAC/DC 1206 |
4,053 |
|
|
CHIP 3216LV | Tape & Reel (TR) | Active | Surface Mount | Board Mount (Cartridge Style Excluded) | 1.5 A | 125 V | 125 V | Fast Blow | 50A | 0.038 | CSA, UL | -65°C ~ 125°C | - | 0.126" L x 0.063" W x 0.035" H (3.20mm x 1.60mm x 0.90mm) | |
|
37303150410FUSE BRD MNT 315MA 250VAC RADIAL |
675 |
|
|
TR5® 373 | Bulk | Active | Through Hole | Board Mount (Cartridge Style Excluded) | 315 mA | 250 V | - | Fast Blow | 50A | 0.032 | CSA, cULus | -40°C ~ 85°C | - | 0.335" Dia x 0.315" H (8.50mm x 8.00mm) | |
|
CC12H15A-TRFUSE BOARD MOUNT 15A 32VDC 1206 |
1,835 |
|
|
CC12H | Tape & Reel (TR) | Active | Surface Mount | Board Mount (Cartridge Style Excluded) | 15 A | - | 32 V | - | 100A | 40.0 | cURus | -55°C ~ 125°C | - | 0.063" L x 0.126" W x 0.024" H (1.60mm x 3.20mm x 0.60mm) | |
|
023003.5DRT1PFUSE GLASS 3.5A 250VAC 125VDC |
721 |
|
|
230 | Tape & Reel (TR) | Active | Through Hole | Cartridge, Glass | 3.5 A | 250 V | 125 V | Slow Blow | 100A AC, 10kA DC | 110.0 | CE, CSA, PSE, UL | -55°C ~ 125°C | - | 0.177" Dia x 0.571" L (4.50mm x 14.50mm) |
Category Overview
Fuses Products & Selection Guide
Fuses are widely used in industrial automation, automotive electronics, communication equipment, consumer electronics, new energy systems, and many other electronic applications. We offer products from multiple manufacturers, packages, and specifications to help engineers and buyers compare and source suitable components.
Use the manufacturer, key specification, availability, and Datasheet filters to narrow down the right Fuses. If the exact part is not listed, submit an inquiry and our team can help check stock, lead time, and suitable alternatives.
FAQ
How do I choose the right Fuses?
Start with the required electrical specifications, package, operating temperature, application conditions, and manufacturer preference, then compare availability and lead time.
Can I order based on the stock shown on this page?
Inventory can change with supply conditions. For project or volume requirements, please submit an inquiry so current stock, pricing, and lead time can be confirmed.
What if the exact part number I need is not listed?
Send us the part number and required quantity. We can help source hard-to-find parts and suggest suitable alternatives based on key specifications.
Do you provide Datasheets and technical documents?
Yes. Use the Datasheet links in the product list to view available technical documents. If a document is unavailable, contact us and we can help check it.