| Photo | Mfr. Part # | Availability | Quantity | Datasheet | Series | Package/Case | Packaging | Product Status | For Measuring | Sensor Type | Current - Sensing | Number of Channels | Output | Sensitivity | Frequency | Linearity | Accuracy | Voltage - Supply | Response Time | Current - Supply (Max) | Operating Temperature | Grade | Qualification | Polarization | Mounting Type | Supplier Device Package |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
TMCS1101A1BQDTCURRENT SENSOR |
55 |
|
|
- | 8-SOIC (0.154", 3.90mm Width) | Tape & Reel (TR) | Obsolete | AC/DC | Hall Effect | 45A | 1 | Ratiometric, Voltage | 50mV/A | 80kHz | ±0.05% | - | 3V ~ 5.5V | 6.5µs | 6mA | -40°C ~ 125°C | - | - | Bidirectional | Surface Mount | 8-SOIC |
|
CQ330ESENSOR CURRENT HALL 20.5A AC/DC |
89 |
|
|
CQ | 24-LSSOP (0.220", 5.60mm Width), 10 Leads | Tape & Reel (TR) | Obsolete | AC/DC | Hall Effect, Open Loop | 20.5A | 1 | Ratiometric, Voltage | 200mv/A | 1MHz | ±0.6% | ±0.5% | 4.5V ~ 5.5V | 0.5µs | 11mA | -40°C ~ 90°C | - | - | Bidirectional | Surface Mount | 24-VSOP |
|
T60404N4647X664CURRENT SENSOR, 50A, 3 PRI PINS, |
88 |
|
|
- | 10-DIP Module | Box | Active | AC/DC | Closed Loop | 50A | 1 | Ratiometric, Voltage | - | DC ~ 200kHz | ±0.1% | ±0.7% | 4.75V ~ 5.25V | 300ns | 15mA | -40°C ~ 85°C | - | - | Unidirectional | Through Hole | - |
|
TL150-A2PVCURRENT SENSOR 150A 1 CHANNEL HA |
75 |
|
|
TLxxx-A2PV | Module, Single Pass Through | Tray | Not For New Designs | AC/DC | Hall Effect, Closed Loop | 150A | 1 | Ratiometric, Voltage | 4.167mV/A | DC ~ 200kHz | ±0.1% | ±0.5% | 4.75V ~ 5.25V | 300ns | 14mA | -40°C ~ 105°C | - | - | Bidirectional | Through Hole | - |
|
TL100-A2PVCURRENT SENSOR 100A 1 CHANNEL HA |
62 |
|
|
TL1xx-A2PV | Module, Single Pass Through | Tray | Not For New Designs | AC/DC | Hall Effect, Closed Loop | 100A | 1 | Ratiometric, Voltage | 6.25mV/A | DC ~ 200kHz | ±0.1% | ±0.5% | 4.75V ~ 5.25V | 300ns | 14mA | -40°C ~ 105°C | - | - | Bidirectional | Through Hole | - |
|
TLB6-A1PDCURRENT SENSOR 80/40A 6MA 1 CHAN |
60 |
|
|
- | Module, Single Pass Through | Tray | Not For New Designs | AC/DC | Open Loop | 80A | 1 | Voltage | - | 50Hz | - | - | 4.85V ~ 5.15V | 60ms | 6mA | -40°C ~ 85°C | - | - | Unidirectional | Through Hole | - |
|
TL100P-D1CCURRENT SENSOR 100A 1 CHANNEL HA |
47 |
|
|
TLx00P-D1C | Module, Single Pass Through | Tray | Not For New Designs | AC/DC | Hall Effect, Closed Loop | 100A | 1 | Ratiometric, Current | - | 0Hz ~ 100kHz | ±0.1% | ±0.5% | ±12V ~ 15V | 1µs | 25mA | -40°C ~ 85°C | - | - | Bidirectional | Chassis Mount | - |
|
TL300-D1CCURRENT SENSOR 300A 1 CHANNEL HA |
39 |
|
|
TLx00-D1C | Module, Single Pass Through | Tray | Not For New Designs | AC/DC | Hall Effect, Closed Loop | 300A | 1 | Ratiometric, Current | - | 0Hz ~ 100kHz | ±0.1% | ±0.5% | ±12V ~ 15V | 1µs | 25mA | -40°C ~ 85°C | - | - | Bidirectional | Chassis Mount | - |
|
TL200P-D1CCURRENT SENSOR 200A 1 CHANNEL HA |
32 |
|
|
TLx00P-D1C | Module, Single Pass Through | Tray | Not For New Designs | AC/DC | Hall Effect, Closed Loop | 200A | 1 | Ratiometric, Current | - | 0Hz ~ 100kHz | ±0.1% | ±0.5% | ±12V ~ 15V | 1µs | 25mA | -40°C ~ 85°C | - | - | Bidirectional | Chassis Mount | - |
|
TL200-D1CCURRENT SENSOR 200A 1 CHANNEL HA |
28 |
|
|
TLx00-D1C | Module, Single Pass Through | Tray | Not For New Designs | AC/DC | Hall Effect, Closed Loop | 200A | 1 | Ratiometric, Current | - | 0Hz ~ 100kHz | ±0.1% | ±0.5% | ±12V ~ 15V | 1µs | 25mA | -40°C ~ 85°C | - | - | Bidirectional | Chassis Mount | - |
|
TL300P-D1CCURRENT SENSOR 300A 1 CHANNEL HA |
25 |
|
|
TLx00P-D1C | Module, Single Pass Through | Tray | Not For New Designs | AC/DC | Hall Effect, Closed Loop | 300A | 1 | Ratiometric, Current | - | 0Hz ~ 100kHz | ±0.1% | ±0.5% | ±12V ~ 15V | 1µs | 25mA | -40°C ~ 85°C | - | - | Bidirectional | Chassis Mount | - |
|
TLB6-A1TDMCURRENT SENSOR 40A 6MA 1 CHANNEL |
20 |
|
|
- | Module | Tray | Not For New Designs | AC/DC | Open Loop | 40A | 1 | Voltage | - | 50Hz ~ 1kHz | - | - | 4.85V ~ 5.15V | 30ms | 6mA | -40°C ~ 85°C | - | - | Unidirectional | Through Hole | - |
|
TL100-A2TPVCURRENT SENSOR 100A 1 CHANNEL HA |
77 |
|
|
TL1xx-A2TPV | Module, Single Pass Through | Tray | Not For New Designs | AC/DC | Hall Effect, Closed Loop | 100A | 1 | Ratiometric, Voltage | 6.25mV/A | DC ~ 200kHz | ±0.1% | ±0.5% | 4.75V ~ 5.25V | 300ns | 14mA | -40°C ~ 105°C | - | - | Bidirectional | Through Hole | - |
|
TL150-A2TPVCURRENT SENSOR 150A 1 CHANNEL HA |
65 |
|
|
TLxxx-A2TPV | Module, Single Pass Through | Tray | Not For New Designs | AC/DC | Hall Effect, Closed Loop | 150A | 1 | Ratiometric, Voltage | 4.167mV/A | DC ~ 200kHz | ±0.1% | ±0.5% | 4.75V ~ 5.25V | 300ns | 14mA | -40°C ~ 105°C | - | - | Bidirectional | Through Hole | - |
|
TL200-A2TPVCURRENT SENSOR 200A 1 CHANNEL HA |
62 |
|
|
TLxxx-A2TPV | Module, Single Pass Through | Tray | Not For New Designs | AC/DC | Hall Effect, Closed Loop | 200A | 1 | Ratiometric, Voltage | 3.125mV/A | DC ~ 200kHz | ±0.1% | ±0.5% | 4.75V ~ 5.25V | 300ns | 14mA | -40°C ~ 105°C | - | - | Bidirectional | Through Hole | - |
|
TL100-D2CCURRENT SENSOR 100A 1 CHANNEL HA |
32 |
|
|
TLx00-D2C | Module | Box | Not For New Designs | AC/DC | Hall Effect, Closed Loop | 100A | 1 | Ratiometric, Current | - | 0Hz ~ 100kHz | ±0.05% | ±0.3% | ±12V ~ 15V | 2µs | 25mA | -40°C ~ 85°C | - | - | Bidirectional | Chassis Mount | - |
|
TL300-D2CCURRENT SENSOR 300A 1 CHANNEL HA |
14 |
|
|
TLx00-D2C | Module | Bulk | Not For New Designs | AC/DC | Hall Effect, Closed Loop | 300A | 1 | Ratiometric, Current | - | 0Hz ~ 100kHz | 0.01% | ±0.3% | ±12V ~ 15V | 2µs | 25mA | -40°C ~ 85°C | - | - | Bidirectional | Chassis Mount | - |
|
T60404N4647X260CURRENT SENSOR 100A/150A, PRI OP |
45 |
|
|
- | Module, Single Pass Through | Box | Active | AC/DC | Closed Loop | 100A, 150A | 1 | Ratiometric, Voltage | - | DC ~ 100kHz | ±0.1% | ±0.7% | 4.75V ~ 5.25V | 1µs | 15mA | -40°C ~ 85°C | - | - | Unidirectional | Through Hole | - |
|
ACI-0.5-LAC CURRENT INDICATOR, LED |
34 |
|
|
AMPFlasher™ ACI | Module | Box | Active | AC | Current Indicator | 500mA | 1 | LED | - | 50Hz ~ 400Hz | - | - | - | - | - | -20°C ~ 50°C | - | - | Unidirectional | Chassis Mount | - |
|
T60404N4646X921DIFFERENTIAL CURRENT SENSOR, 300 |
12 |
|
|
- | 10-DIP Module | Box | Active | AC/DC | Closed Loop | 50A | 1 | Ratiometric, Voltage | - | DC ~ 8kHz | ±1% | ±1.5% | 4.75V ~ 5.25V | 35µs | 15mA | -40°C ~ 85°C | - | - | Unidirectional | Through Hole | - |
Category Overview
Current Sensors Products & Selection Guide
Current Sensors are widely used in industrial automation, automotive electronics, communication equipment, consumer electronics, new energy systems, and many other electronic applications. We offer products from multiple manufacturers, packages, and specifications to help engineers and buyers compare and source suitable components.
Use the manufacturer, key specification, availability, and Datasheet filters to narrow down the right Current Sensors. If the exact part is not listed, submit an inquiry and our team can help check stock, lead time, and suitable alternatives.
FAQ
How do I choose the right Current Sensors?
Start with the required electrical specifications, package, operating temperature, application conditions, and manufacturer preference, then compare availability and lead time.
Can I order based on the stock shown on this page?
Inventory can change with supply conditions. For project or volume requirements, please submit an inquiry so current stock, pricing, and lead time can be confirmed.
What if the exact part number I need is not listed?
Send us the part number and required quantity. We can help source hard-to-find parts and suggest suitable alternatives based on key specifications.
Do you provide Datasheets and technical documents?
Yes. Use the Datasheet links in the product list to view available technical documents. If a document is unavailable, contact us and we can help check it.