| Photo | Mfr. Part # | Availability | Quantity | Datasheet | Series | Package/Case | Packaging | Product Status | For Measuring | Sensor Type | Current - Sensing | Number of Channels | Output | Sensitivity | Frequency | Linearity | Accuracy | Voltage - Supply | Response Time | Current - Supply (Max) | Operating Temperature | Grade | Qualification | Polarization | Mounting Type | Supplier Device Package |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
|
ACS758LCB-100B-PFF-TSENSOR CURRENT HALL 100A 5-CB |
1,680 |
|
|
- | 5-CB Formed Leads, PFF | Tube | Active | AC/DC | Hall Effect, Open Loop | 100A | 1 | Ratiometric, Voltage | 20mV/A | DC ~ 120kHz | ±1.25% | ±2.4% | 3V ~ 5.5V | 4µs | 13.5mA | -40°C ~ 150°C | Automotive | AEC-Q100 | Bidirectional | Through Hole | 5-CB Module |
|
|
ACS758ECB-200U-PFF-TSENSOR CURRENT HALL 200A 5-CB |
1,668 |
|
|
- | 5-CB Formed Leads, PFF | Tube | Active | DC | Hall Effect, Open Loop | 200A | 1 | Ratiometric, Voltage | 20mV/A | DC ~ 120kHz | ±1% | ±1.2% | 3V ~ 5.5V | 4µs | 13.5mA | -40°C ~ 85°C | Automotive | AEC-Q100 | Unidirectional | Through Hole | 5-CB Module |
|
|
ACS758LCB-100U-PFF-TSENSOR CURRENT HALL 100A 5-CB |
1,265 |
|
|
- | 5-CB Formed Leads, PFF | Tube | Active | DC | Hall Effect, Open Loop | 100A | 1 | Ratiometric, Voltage | 40mV/A | DC ~ 120kHz | ±1.25% | ±2.4% | 3V ~ 5.5V | 4µs | 13.5mA | -40°C ~ 150°C | Automotive | AEC-Q100 | Unidirectional | Through Hole | 5-CB Module |
|
|
ACS758LCB-050U-PFF-TSENSOR CURRENT HALL 50A 5-CB |
1,162 |
|
|
- | 5-CB Formed Leads, PFF | Tube | Active | DC | Hall Effect, Open Loop | 50A | 1 | Ratiometric, Voltage | 60mV/A | DC ~ 120kHz | ±1% | ±2% | 3V ~ 5.5V | 4µs | 13.5mA | -40°C ~ 150°C | Automotive | AEC-Q100 | Unidirectional | Through Hole | 5-CB Module |
|
|
ACS756KCB-050B-PFF-TSENSOR CURRENT HALL |
189 |
|
|
- | 5-CB Formed Leads, PFF | Tube | Active | AC/DC | Hall Effect, Open Loop | 50A | 1 | Ratiometric, Voltage | 40mV/A | DC ~ 120kHz | ±1.8% | ±7.5% | 3V ~ 5.5V | 3µs | 14mA | -40°C ~ 125°C | - | - | Bidirectional | Through Hole | 5-CB Module |
|
|
ACS770LCB-100U-PFF-TSENSOR CURRENT HALL 100A DC |
11,890 |
|
|
ACS770 | 5-CB Formed Leads, PFF | Tube | Active | DC | Hall Effect, Open Loop | 100A | 1 | Ratiometric, Voltage | 40mV/A | DC ~ 120kHz | ±1% | ±0.6% | 5V | 4.6µs | 15mA | -40°C ~ 150°C | - | - | Unidirectional | Through Hole | 5-CB Module |
|
|
ACS770LCB-050B-PFF-TSENSOR CURRENT HALL 50A AC/DC |
11,486 |
|
|
ACS770 | 5-CB Formed Leads, PFF | Tube | Active | AC/DC | Hall Effect, Open Loop | 50A | 1 | Ratiometric, Voltage | 40mV/A | DC ~ 120kHz | ±1% | ±0.6% | 5V | 4.6µs | 15mA | -40°C ~ 150°C | - | - | Bidirectional | Through Hole | 5-CB Module |
|
|
ACS759ECB-200B-PFF-TSENSOR CURRENT HALL 200A AC/DC |
5,393 |
|
|
- | 5-CB Formed Leads, PFF | Tube | Active | AC/DC | Hall Effect, Open Loop | 200A | 1 | Ratiometric, Voltage | 6.6mV/A | DC ~ 120kHz | ±1% | ±4% | 3V ~ 3.6V | 4µs | 13.5mA | -40°C ~ 85°C | - | - | Bidirectional | Through Hole | 5-CB Module |
|
|
ACS770KCB-150B-PFF-TSENSOR CURRENT HALL 150A AC/DC |
4,043 |
|
|
ACS770 | 5-CB Formed Leads, PFF | Tube | Active | AC/DC | Hall Effect, Open Loop | 150A | 1 | Ratiometric, Voltage | 13.3mV/A | DC ~ 120kHz | ±1% | ±0.6% | 5V | 4.6µs | 15mA | -40°C ~ 125°C | - | - | Bidirectional | Through Hole | 5-CB Module |
|
|
ACS770ECB-200B-PFF-TSENSOR CURRENT HALL 200A AC/DC |
3,135 |
|
|
ACS770 | 5-CB Formed Leads, PFF | Tube | Active | AC/DC | Hall Effect, Open Loop | 200A | 1 | Ratiometric, Voltage | 10mV/A | DC ~ 120kHz | ±1% | ±0.6% | 5V | 4.6µs | 15mA | -40°C ~ 85°C | - | - | Bidirectional | Through Hole | 5-CB Module |
|
|
ACS770LCB-100B-PFF-TSENSOR CURRENT HALL 100A AC/DC |
2,336 |
|
|
ACS770 | 5-CB Formed Leads, PFF | Tube | Active | AC/DC | Hall Effect, Open Loop | 100A | 1 | Ratiometric, Voltage | 20mV/A | DC ~ 120kHz | ±1% | ±0.6% | 5V | 4.6µs | 15mA | -40°C ~ 150°C | - | - | Bidirectional | Through Hole | 5-CB Module |
|
|
ACS770KCB-150U-PFF-TSENSOR CURRENT HALL 150A DC |
2,022 |
|
|
ACS770 | 5-CB Formed Leads, PFF | Tube | Active | DC | Hall Effect, Open Loop | 150A | 1 | Ratiometric, Voltage | 26.7mV/A | DC ~ 120kHz | ±1% | ±0.6% | 5V | 4.6µs | 15mA | -40°C ~ 125°C | - | - | Unidirectional | Through Hole | 5-CB Module |
|
|
ACS770ECB-200U-PFF-TSENSOR CURRENT HALL 200A DC |
1,657 |
|
|
ACS770 | 5-CB Formed Leads, PFF | Tube | Active | DC | Hall Effect, Open Loop | 200A | 1 | Ratiometric, Voltage | 20mV/A | DC ~ 120kHz | ±1% | ±0.6% | 5V | 4.6µs | 15mA | -40°C ~ 85°C | - | - | Unidirectional | Through Hole | 5-CB Module |
|
|
ACS759LCB-050B-PFF-TSENSOR CURRENT HALL 50A AC/DC |
748 |
|
|
- | 5-CB Formed Leads, PFF | Tube | Active | AC/DC | Hall Effect, Open Loop | 50A | 1 | Ratiometric, Voltage | 26.4mV/A | DC ~ 120kHz | ±1% | ±3.5% | 3V ~ 3.6V | 4µs | 13.5mA | -40°C ~ 150°C | - | - | Bidirectional | Through Hole | 5-CB Module |
|
|
ACS770LCB-050U-PFF-TSENSOR CURRENT HALL 50A DC |
690 |
|
|
ACS770 | 5-CB Formed Leads, PFF | Tube | Active | DC | Hall Effect, Open Loop | 50A | 1 | Ratiometric, Voltage | 80mV/A | DC ~ 120kHz | ±1% | ±0.6% | 5V | 4.6µs | 15mA | -40°C ~ 150°C | - | - | Unidirectional | Through Hole | 5-CB Module |
|
T60404N4646X651CURRENT SENSOR, 25A, 3 PRI PINS, |
1,765 |
|
|
- | 9-DIP Module | Box | Active | AC/DC | Closed Loop | 25A | 1 | Ratiometric, Voltage | - | DC ~ 200kHz | ±0.1% | ±0.7% | 4.75V ~ 5.25V | 300ns | 15mA | -40°C ~ 85°C | - | - | Unidirectional | Through Hole | - |
|
|
HXS 20-NPSENSOR CURRENT HALL 5A, 10A, 20A |
1,578 |
|
|
HXS | Module | Tube | Not For New Designs | AC/DC | Hall Effect, Open Loop | 5A, 10A, 20A (Selectable) | 1 | Ratiometric, Voltage | - | DC ~ 50kHz | ±0.5% | ±1% | 5V | 5µs | 19mA | -40°C ~ 105°C | - | - | Bidirectional | Through Hole | - |
|
|
HXS 50-NPSENSOR CURRENT 12.5A, 25A, 50A |
399 |
|
|
HXS | Module | Tube | Not For New Designs | AC/DC | Hall Effect, Open Loop | 12.5A, 25A, 50A (Selectable) | 1 | Ratiometric, Voltage | - | DC ~ 50kHz | ±0.5% | ±1% | 5V | 5µs | 19mA | -40°C ~ 105°C | - | - | Bidirectional | Through Hole | - |
|
HO 6-PSENSOR CURRENT HALL 6A AC/DC |
283 |
|
|
HO-P | Module, Single Pass Through | Tray | Active | AC/DC | Hall Effect, Open Loop | 6A | 1 | Ratiometric, Voltage | - | DC ~ 250kHz | ±0.5% | ±1.4% | 5V | 3.5µs | 25mA | -40°C ~ 105°C | - | - | Bidirectional | Through Hole | - |
|
T60404N4646X412CURRENT SENSOR, 100A, 3 PRI PINS |
1,357 |
|
|
- | 9-DIP Module | Box | Active | AC/DC | Closed Loop | 50A, 100A | 1 | Ratiometric, Current | - | DC ~ 200kHz | ±0.1% | ±0.5% | ±11.4V ~ 15.75V | 500ns | 18.5mA | -40°C ~ 85°C | - | - | Unidirectional | Through Hole | - |
Category Overview
Current Sensors Products & Selection Guide
Current Sensors are widely used in industrial automation, automotive electronics, communication equipment, consumer electronics, new energy systems, and many other electronic applications. We offer products from multiple manufacturers, packages, and specifications to help engineers and buyers compare and source suitable components.
Use the manufacturer, key specification, availability, and Datasheet filters to narrow down the right Current Sensors. If the exact part is not listed, submit an inquiry and our team can help check stock, lead time, and suitable alternatives.
FAQ
How do I choose the right Current Sensors?
Start with the required electrical specifications, package, operating temperature, application conditions, and manufacturer preference, then compare availability and lead time.
Can I order based on the stock shown on this page?
Inventory can change with supply conditions. For project or volume requirements, please submit an inquiry so current stock, pricing, and lead time can be confirmed.
What if the exact part number I need is not listed?
Send us the part number and required quantity. We can help source hard-to-find parts and suggest suitable alternatives based on key specifications.
Do you provide Datasheets and technical documents?
Yes. Use the Datasheet links in the product list to view available technical documents. If a document is unavailable, contact us and we can help check it.