| Photo | Mfr. Part # | Availability | Quantity | Datasheet | Series | Package/Case | Packaging | Product Status | For Measuring | Sensor Type | Current - Sensing | Number of Channels | Output | Sensitivity | Frequency | Linearity | Accuracy | Voltage - Supply | Response Time | Current - Supply (Max) | Operating Temperature | Grade | Qualification | Polarization | Mounting Type | Supplier Device Package |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
MLX91218LDC-ARX-503-TUGEN2.75 HISPEED IMC.HALL PROG.CU |
80 |
|
|
- | 8-SOIC (0.154", 3.90mm Width) | Tube | Active | DC | Hall Effect | - | 1 | Ratiometric, Voltage | - | DC ~ 400kHz | ±0.5% | - | 4.5V ~ 5.5V | 2µs | 19mA | -40°C ~ 150°C | - | - | Bidirectional | Surface Mount | 8-SOIC |
|
SNS-CURRENT-CT013-100AIC |
14 |
|
|
- | Module | Bulk | Active | AC | Current Sensor | 100A | 1 | 0V ~ 1V, 0 ~ 50mA | - | - | ±3% | - | - | - | - | -25°C ~ 70°C | - | - | - | Chassis Mount | - |
|
HO 25-NSM/SP33-1000SENSOR CURRENT HALL 25A AC/DC |
31 |
|
|
HO-NSM-0000 | Module | Tray | Active | AC/DC | Hall Effect, Open Loop | 25A | 1 | Ratiometric, Voltage | - | DC ~ 250kHz | ±0.5% | ±1% | 3.3V | 3.5µs | 25mA | -40°C ~ 105°C | - | - | Bidirectional | Surface Mount | - |
|
HO 15-NP/SP33-1000SENSOR CURRENT HALL 15A AC/DC |
14 |
|
|
HO-NP-0000 | Module | Tray | Active | AC/DC | Hall Effect, Open Loop | 15A | 1 | Ratiometric, Voltage | - | DC ~ 250kHz | ±0.5% | ±1% | 3.3V | 3.5µs | 25mA | -40°C ~ 105°C | - | - | Bidirectional | Through Hole | - |
|
HO 8-NSM/SP33-1000SENSOR CURRENT HALL 8A AC/DC |
12 |
|
|
HO-NSM-0000 | Module | Tray | Active | AC/DC | Hall Effect, Open Loop | 8A | 1 | Ratiometric, Voltage | - | DC ~ 250kHz | ±0.5% | ±1% | 3.3V | 3.5µs | 25mA | -40°C ~ 105°C | - | - | Bidirectional | Surface Mount | - |
|
HO 200-PW-0000DIGITAL OUTPUT OL PCB MT 200A |
95 |
|
|
HO-PW | Module, Single Pass Through | Bulk | Active | AC/DC | Hall Effect, Open Loop | 200A | 1 | Ratiometric, Voltage | - | - | ±0.5% | - | 4.5V ~ 5.5V | - | 31mA | -40°C ~ 105°C | - | - | Bidirectional | Through Hole | - |
|
HO 150-PW-0000DIGITAL OUTPUT OL PCB MT 150A |
60 |
|
|
HO-PW | Module, Single Pass Through | Bulk | Active | AC/DC | Hall Effect, Open Loop | 150A | 1 | Ratiometric, Voltage | - | - | ±0.5% | - | 4.5V ~ 5.5V | - | 31mA | -40°C ~ 105°C | - | - | Bidirectional | Through Hole | - |
|
HO 150-NPW-0000DIGITAL OUTPUT OL PCB MT 150A |
79 |
|
|
HO-NPW | Module | Bulk | Active | AC/DC | Hall Effect, Open Loop | 150A | 1 | Ratiometric, Voltage | - | - | ±0.5% | - | 4.5V ~ 5.5V | - | 31mA | -40°C ~ 105°C | - | - | Bidirectional | Through Hole | - |
|
HO 120-NPW-0000DIGITAL OUTPUT OL PCB MT 120A |
22 |
|
|
HO-NPW | Module | Bulk | Active | AC/DC | Hall Effect, Open Loop | 120A | 1 | Ratiometric, Voltage | - | - | ±0.5% | - | 4.5V ~ 5.5V | - | 31mA | -40°C ~ 105°C | - | - | Bidirectional | Through Hole | - |
|
RC01-100TRANSF CURR SENSE 100MV/KA 50HZ |
40 |
|
|
RC01-SSS-O | Module, Single Pass Through | Tray | Active | AC/DC | Rogowski Coil | 200A | 1 | - | 0.1mV/A | 50kHz | - | - | - | - | - | -20°C ~ 80°C | - | - | - | Through Hole | - |
|
HOB 75-P/SP331 MHZ OPEN-LOOP CURRENT SENSOR 7 |
30 |
|
|
HOB-P/SP33 | Module | Bulk | Active | AC/DC | Open Loop | 75A | 1 | Voltage | 6.133mV/A | 1MHz | ±0.6% | - | 3.14V ~ 3.46V | - | 24mA | -40°C ~ 105°C | - | - | Bidirectional | Through Hole | - |
|
|
HO 40-NPSENSOR CURRENT HALL 40A AC/DC |
87 |
|
|
HO-NP | Module | Tray | Active | AC/DC | Hall Effect, Open Loop | 40A | 1 | Ratiometric, Voltage | - | DC ~ 350kHz | ±0.5% | ±1.5% | 5V | 2.5µs | 25mA | -40°C ~ 105°C | - | - | Bidirectional | Through Hole | - |
|
RC01-200TRANSF CURR SENSE 200MV/KA 50HZ |
40 |
|
|
RC01-SSS-O | Module, Single Pass Through | Tray | Active | AC/DC | Rogowski Coil | 200A | 1 | - | 0.2mV/A | 50kHz | - | - | - | - | - | -20°C ~ 80°C | - | - | - | Through Hole | - |
|
HO 250-PW-0000DIGITAL OUTPUT OL PCB MT 250A |
64 |
|
|
HO-PW | Module, Single Pass Through | Bulk | Active | AC/DC | Hall Effect, Open Loop | 250A | 1 | Ratiometric, Voltage | - | - | ±0.5% | - | 4.5V ~ 5.5V | - | 31mA | -40°C ~ 105°C | - | - | Bidirectional | Through Hole | - |
|
HO 250-SW-0000DIGITAL OUTPUT OL PANEL MT 250A |
82 |
|
|
HO-SW | Module, Single Pass Through | Bulk | Active | AC/DC | Hall Effect, Open Loop | 250A | 1 | Ratiometric, Voltage | - | - | ±0.5% | - | 4.5V ~ 5.5V | - | 31mA | -40°C ~ 105°C | - | - | Bidirectional | Chassis Mount | - |
|
HO 150-SW-0000DIGITAL OUTPUT OL PANEL MT 150A |
76 |
|
|
HO-SW | Module, Single Pass Through | Bulk | Active | AC/DC | Hall Effect, Open Loop | 150A | 1 | Ratiometric, Voltage | - | - | ±0.5% | - | 4.5V ~ 5.5V | - | 31mA | -40°C ~ 105°C | - | - | Bidirectional | Chassis Mount | - |
|
HOB 100-P/SP11 MHZ OPEN-LOOP CURRENT SENSOR 1 |
58 |
|
|
HOB-P/SP1 | Module | Bulk | Active | AC/DC | Open Loop | 100A | 1 | Voltage | 16mV/A | 1MHz | ±0.5% | - | 4.6V ~ 5.5V | - | 26mA | -40°C ~ 105°C | - | - | Bidirectional | Through Hole | - |
|
LA37S600S05KMCURRENT SENSOR (600A; 5V) -40 10 |
94 |
|
|
LA37S S05K | Module, Single Pass Through | Tray | Active | DC | Open Loop | 600A | 1 | Analog Voltage | 1.042mV/A | 100kHz | ±0.5% | ±1.8% | 4.5V ~ 5.5V | 3.5µs | 23mA | -40°C ~ 105°C | - | - | - | Chassis Mount | - |
|
HO 250-PSENSOR CURRENT HALL 250A AC/DC |
93 |
|
|
HO-P | Module, Single Pass Through | Tray | Active | AC/DC | Hall Effect, Open Loop | 250A | 1 | Ratiometric, Voltage (Selectable) | - | DC ~ 100kHz | ±0.5% | ±1% | 5V | 3.5µs | 25mA | -40°C ~ 105°C | - | - | Bidirectional | Through Hole | - |
|
HO 180-PSENSOR CURRENT HALL 180A AC/DC |
6 |
|
|
HO-P | Module, Single Pass Through | Tray | Active | AC/DC | Hall Effect, Open Loop | 180A | 1 | Ratiometric, Voltage (Selectable) | - | DC ~ 100kHz | ±0.5% | ±1% | 5V | 3.5µs | 25mA | -40°C ~ 105°C | - | - | Bidirectional | Through Hole | - |
Category Overview
Current Sensors Products & Selection Guide
Current Sensors are widely used in industrial automation, automotive electronics, communication equipment, consumer electronics, new energy systems, and many other electronic applications. We offer products from multiple manufacturers, packages, and specifications to help engineers and buyers compare and source suitable components.
Use the manufacturer, key specification, availability, and Datasheet filters to narrow down the right Current Sensors. If the exact part is not listed, submit an inquiry and our team can help check stock, lead time, and suitable alternatives.
FAQ
How do I choose the right Current Sensors?
Start with the required electrical specifications, package, operating temperature, application conditions, and manufacturer preference, then compare availability and lead time.
Can I order based on the stock shown on this page?
Inventory can change with supply conditions. For project or volume requirements, please submit an inquiry so current stock, pricing, and lead time can be confirmed.
What if the exact part number I need is not listed?
Send us the part number and required quantity. We can help source hard-to-find parts and suggest suitable alternatives based on key specifications.
Do you provide Datasheets and technical documents?
Yes. Use the Datasheet links in the product list to view available technical documents. If a document is unavailable, contact us and we can help check it.