Current Sensors
| Photo | Mfr. Part # | Availability | Quantity | Datasheet | Series | Package/Case | Packaging | Product Status | For Measuring | Sensor Type | Current - Sensing | Number of Channels | Output | Sensitivity | Frequency | Linearity | Accuracy | Voltage - Supply | Response Time | Current - Supply (Max) | Operating Temperature | Grade | Qualification | Polarization | Mounting Type | Supplier Device Package |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
DS400IDCURRENT TRANSDUCER 400A |
8 |
|
|
DS | Module, Single Pass Through | Bulk | Active | AC/DC | Flux Gate, Closed Loop | 400A | 1 | - | - | DC ~ 300kHz | ±0.00015% | - | ±14.25V ~ 15.75V | 1µs | 104mA | -40°C ~ 85°C | - | - | Bidirectional | Chassis Mount | - |
|
DS300IDCURRENT TRANSDUCER 300A |
3 |
|
|
DS | Module, Single Pass Through | Bulk | Active | AC/DC | Flux Gate, Closed Loop | 300A | 1 | - | - | DC ~ 1MHz | ±0.00015% | - | ±14.25V ~ 15.75V | 1µs | 104mA | -40°C ~ 85°C | - | - | Bidirectional | Chassis Mount | - |
|
DS600IDCURRENT TRANSDUCER 600A |
11 |
|
|
DS | Module, Single Pass Through | Bulk | Active | AC/DC | Flux Gate, Closed Loop | 600A | 1 | - | - | DC ~ 500kHz | ±0.0001% | - | ±14.25V ~ 15.75V | 1µs | 104mA | -40°C ~ 85°C | - | - | Bidirectional | Chassis Mount | - |
|
DS200UB-10VCURRENT TRANSDUCER 200A |
10 |
|
|
DS | Module, Single Pass Through | Bulk | Active | AC/DC | Flux Gate, Closed Loop | 200A | 1 | Ratiometric, Voltage | - | DC ~ 500kHz | ±0.005% | - | ±14.25V ~ 15.75V | 1µs | 104mA | -40°C ~ 85°C | - | - | Bidirectional | Chassis Mount | - |
|
DS400UB-10VCURRENT TRANSDUCER 400A |
4 |
|
|
DS | Module, Single Pass Through | Bulk | Active | AC/DC | Flux Gate, Closed Loop | 400A | 1 | - | - | DC ~ 500kHz | ±0.0015% | - | ±14.25V ~ 15.75V | 1µs | 104mA | -40°C ~ 85°C | - | - | Bidirectional | Chassis Mount | - |
|
DS600UB-10VCURRENT TRANSDUCER 600A |
5 |
|
|
DS | Module, Single Pass Through | Bulk | Active | AC/DC | Flux Gate, Closed Loop | 600A | 1 | Ratiometric, Voltage | - | DC ~ 300kHz | ±0.004% | - | ±14.25V ~ 15.75V | 1µs | 104mA | -40°C ~ 85°C | - | - | Bidirectional | Chassis Mount | - |
|
DN1000ID1000A CURRENT TRANSDUCER CURRENT |
12 |
|
|
DN | Module, Single Pass Through | Bulk | Active | AC/DC | Flux Gate, Closed Loop | 1000A | 1 | Ratiometric, Current | - | 31.25kHz | - | - | 14.25V ~ 15.75V | 1µs | 1.1A | -40°C ~ 85°C | - | - | Bidirectional | Chassis Mount | - |
|
DS1000UB-10VCURRENT TRANSDUCER 1000A |
2 |
|
|
DS | Module, Single Pass Through | Bulk | Active | AC/DC | Flux Gate, Closed Loop | 1000A | 1 | Ratiometric, Voltage | - | DC ~ 300kHz | ±0.0035% | - | ±14.25V ~ 15.75V | 1µs | 104mA | -40°C ~ 55°C | - | - | Bidirectional | Chassis Mount | - |
|
IN 1000-S1000A ULTRA ACCURACY |
2 |
|
|
IN | Module, Single Pass Through | Box | Active | AC/DC | Flux Gate, Closed Loop | 1000A | 1 | Current | - | DC ~ 440kHz | ±0.0002% | - | ±14.25V ~ 15.75V | 1µs | 1.12A (Typ) | -40°C ~ 85°C | - | - | Bidirectional | Chassis Mount | - |
|
DM1200IDCURRENT TRANSDUCER 1200A |
10 |
|
|
DM | Module, Single Pass Through | Bulk | Active | AC/DC | Flux Gate, Closed Loop | 1200A | 1 | Ratiometric, Current | - | DC ~ 300kHz | ±0.0001% | - | ±14.25V ~ 15.75V | 1µs | 120mA | -40°C ~ 65°C | - | - | Bidirectional | Chassis Mount | - |
|
IN 2000-S2000A ULTRA ACCURACY |
2 |
|
|
IN | Module, Single Pass Through | Box | Active | AC/DC | Flux Gate, Closed Loop | 2000A | 1 | Current | - | DC ~ 140kHz | ±0.0002% | - | ±14.25V ~ 15.75V | 1µs | 1.725A | -40°C ~ 85°C | - | - | Bidirectional | Chassis Mount | - |
|
MCS1802GS-40-P3.3V, LINEAR HALL-EFFECT CURRENT |
50 |
|
|
- | 8-SOIC (0.154", 3.90mm Width) | Tape & Reel (TR) | Active | AC/DC | Hall Effect | 40A | 1 | Ratiometric, Voltage | 33mV/A | 100kHz | ±0.5% | ±2.5% | 3V ~ 3.6V | 5µs | 10.5mA | -40°C ~ 125°C (TJ) | - | - | Bidirectional | Surface Mount | 8-SOIC |
|
HO 150-NP-0100SENSOR CURRENT HALL 150A AC/DC |
60 |
|
|
HO-NP | Module | Tray | Active | AC/DC | Hall Effect, Open Loop | 150A | 1 | Ratiometric, Voltage | - | DC ~ 350kHz | ±0.4% | ±1.2% | 5V | 2.5µs | 25mA | -40°C ~ 105°C | - | - | Bidirectional | Through Hole | - |
|
HOB 75-P/SP11 MHZ OPEN-LOOP CURRENT SENSOR 7 |
98 |
|
|
HOB-P/SP1 | Module | Bulk | Active | AC/DC | Open Loop | 75A | 1 | Voltage | 21.333mV/A | 1MHz | ±0.6% | - | 4.6V ~ 5.5V | - | 26mA | -40°C ~ 105°C | - | - | Bidirectional | Through Hole | - |
|
HOB 130-P/SP331 MHZ OPEN-LOOP CURRENT SENSOR 1 |
71 |
|
|
HOB-P/SP33 | Module | Bulk | Active | AC/DC | Open Loop | 130A | 1 | Voltage | 4.6mV/A | 1MHz | ±0.45% | - | 3.14V ~ 3.46V | - | 24mA | -40°C ~ 105°C | - | - | Bidirectional | Through Hole | - |
|
HOB 50-P1 MHZ OPEN-LOOP CURRENT SENSOR 5 |
62 |
|
|
HOB-P | Module | Bulk | Active | AC/DC | Open Loop | 50A | 1 | Voltage | 16mV/A | 1MHz | ±0.7% | - | 4.6V ~ 5.5V | 200ns | 26mA | -40°C ~ 105°C | - | - | Bidirectional | Through Hole | - |
|
HOB 50-P/SP331 MHZ OPEN-LOOP CURRENT SENSOR 5 |
36 |
|
|
HOB-P/SP33 | Module | Bulk | Active | AC/DC | Open Loop | 50A | 1 | Voltage | 9.2mV/A | 1MHz | ±0.7% | - | 3.14V ~ 3.46V | - | 24mA | -40°C ~ 105°C | - | - | Bidirectional | Through Hole | - |
|
HO 120-PSENSOR CURRENT HALL 120A AC/DC |
75 |
|
|
HO-P | Module, Single Pass Through | Tray | Active | AC/DC | Hall Effect, Open Loop | 120A | 1 | Ratiometric, Voltage (Selectable) | - | DC ~ 100kHz | ±0.5% | ±1% | 5V | 3.5µs | 25mA | -40°C ~ 105°C | - | - | Bidirectional | Through Hole | - |
|
HO 100-PSENSOR CURRENT HALL 100A AC/DC |
66 |
|
|
HO-P | Module, Single Pass Through | Tray | Active | AC/DC | Hall Effect, Open Loop | 100A | 1 | Ratiometric, Voltage (Selectable) | - | DC ~ 100kHz | ±0.5% | ±1% | 5V | 3.5µs | 25mA | -40°C ~ 105°C | - | - | Bidirectional | Through Hole | - |
|
CSHV200A-001CSHV200A-001 CURRENT SENSOR |
20 |
|
|
CSHV | Module, Single Pass Through | Box | Active | AC/DC | Hall Effect, Open Loop | 200A | 1 | Ratiometric, Voltage | 10mV/A | 45kHz | ±1% | ±2% | 4.5V ~ 5.5V | 6µs | 16mA | -40°C ~ 125°C | - | - | Bidirectional | Chassis Mount | - |
Category Overview
Current Sensors Products & Selection Guide
Current Sensors are widely used in industrial automation, automotive electronics, communication equipment, consumer electronics, new energy systems, and many other electronic applications. We offer products from multiple manufacturers, packages, and specifications to help engineers and buyers compare and source suitable components.
Use the manufacturer, key specification, availability, and Datasheet filters to narrow down the right Current Sensors. If the exact part is not listed, submit an inquiry and our team can help check stock, lead time, and suitable alternatives.
FAQ
How do I choose the right Current Sensors?
Start with the required electrical specifications, package, operating temperature, application conditions, and manufacturer preference, then compare availability and lead time.
Can I order based on the stock shown on this page?
Inventory can change with supply conditions. For project or volume requirements, please submit an inquiry so current stock, pricing, and lead time can be confirmed.
What if the exact part number I need is not listed?
Send us the part number and required quantity. We can help source hard-to-find parts and suggest suitable alternatives based on key specifications.
Do you provide Datasheets and technical documents?
Yes. Use the Datasheet links in the product list to view available technical documents. If a document is unavailable, contact us and we can help check it.