Current Sensors
| Photo | Mfr. Part # | Availability | Quantity | Datasheet | Series | Package/Case | Packaging | Product Status | For Measuring | Sensor Type | Current - Sensing | Number of Channels | Output | Sensitivity | Frequency | Linearity | Accuracy | Voltage - Supply | Response Time | Current - Supply (Max) | Operating Temperature | Grade | Qualification | Polarization | Mounting Type | Supplier Device Package |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
RCS-1800-8003PH 18" COILS 800A:333MV |
93 |
|
|
RCS | Module | Bag | Active | AC | AC Single Phase/Three Phase | 800A | 3 | Ratiometric, Voltage | - | - | - | ±1% | 9V ~ 36VDC | - | - | -20°C ~ 105°C | - | - | - | Chassis Mount | - |
|
RCS-1800-2503PH 18" COILS 250A:333MV |
31 |
|
|
RCS | Module | Bag | Active | AC | AC Single Phase/Three Phase | 250A | 3 | Ratiometric, Voltage | - | - | - | ±1% | 9V ~ 36VDC | - | - | -20°C ~ 105°C | - | - | - | Chassis Mount | - |
|
RCS-1800-15003PH 18" COILS 1500A:333MV |
30 |
|
|
RCS | Module | Bag | Active | AC | AC Single Phase/Three Phase | 1500A | 3 | Ratiometric, Voltage | - | - | - | ±1% | 9V ~ 36VDC | - | - | -20°C ~ 105°C | - | - | - | Chassis Mount | - |
|
T60404N4646X653CURRENT SENSOR, 6A, 3 PRI |
497 |
|
|
- | 9-DIP Module | Bulk | Active | AC/DC | Closed Loop | 6A | 1 | Ratiometric, Voltage | - | DC ~ 100kHz | ±0.1% | ±0.7% | 4.75V ~ 5.25V | 300ns | 15mA | -40°C ~ 85°C | - | - | Unidirectional | Through Hole | - |
|
HS100T01100 Amps rated open loop Hall ef |
1,600 |
|
|
- | Module, Single Pass Through | Bulk | Active | AC/DC | Hall Effect | 100A | 1 | Analog Voltage | - | DC ~ 50kHz | ±1% | ±1% | ±15V | 3µs | 15mA | -10°C ~ 80°C | - | - | Bidirectional | Chassis Mount | - |
|
HS300T01300 Amps rated open loop Hall ef |
352 |
|
|
- | Module, Single Pass Through | Bulk | Active | AC/DC | Hall Effect | 300A | 1 | Analog Voltage | - | DC ~ 50kHz | ±1% | ±1% | ±15V | 3µs | 15mA | -10°C ~ 80°C | - | - | Bidirectional | Chassis Mount | - |
|
HS200T01200 Amps rated open loop Hall ef |
345 |
|
|
- | Module, Single Pass Through | Bulk | Active | AC/DC | Hall Effect | 200A | 1 | Analog Voltage | - | DC ~ 50kHz | ±1% | ±1% | ±15V | 3µs | 15mA | -10°C ~ 80°C | - | - | Bidirectional | Chassis Mount | - |
|
HS050T0150 Amps rated open loop Hall eff |
340 |
|
|
- | Module, Single Pass Through | Bulk | Active | AC/DC | Hall Effect | 50A | 1 | Analog Voltage | - | DC ~ 50kHz | ±1% | ±1% | ±15V | 3µs | 15mA | -10°C ~ 80°C | - | - | Bidirectional | Chassis Mount | - |
|
HS400T01400 Amps rated open loop Hall ef |
155 |
|
|
- | Module, Single Pass Through | Bulk | Active | AC/DC | Hall Effect | 400A | 1 | Analog Voltage | - | DC ~ 50kHz | ±1% | ±1% | ±15V | 3µs | 15mA | -10°C ~ 80°C | - | - | Bidirectional | Chassis Mount | - |
|
T60404N4646X662Closed Loop Current Sensor DC |
240 |
|
|
- | 10-DIP Module | Bulk | Active | AC/DC | Closed Loop | 15A | 1 | Ratiometric, Voltage | - | DC ~ 200kHz | ±0.1% | ±0.7% | 4.75V ~ 5.25V | 300ns | 15mA | -40°C ~ 85°C | - | - | Unidirectional | Through Hole | - |
|
T60404N4646X664Closed Loop Current Sensor AC/ |
215 |
|
|
- | 10-DIP Module | Bulk | Active | AC/DC | Closed Loop | 50A | 1 | Ratiometric, Voltage | - | DC ~ 200kHz | ±0.1% | ±0.7% | 4.75V ~ 5.25V | 300ns | 15mA | -40°C ~ 85°C | - | - | Unidirectional | Through Hole | - |
|
VH1K0T02Voltage sensors 1000 Vrms rating |
700 |
|
|
- | 5-DIP Module | Bulk | Active | AC/DC | Hall Effect | 10mA | 1 | Current | - | - | ±0.2% | ±0.8% | ±15V | - | - | -40°C ~ 85°C | - | - | Bidirectional | Through Hole | - |
|
HK500T09500 Amps rated Split core Hall e |
200 |
|
|
- | Module, Single Pass Through | Bulk | Active | AC/DC | Hall Effect | 500A | 1 | Analog Voltage | - | DC ~ 20kHz | ±1% | ±2% | ±15V | 3µs | 25mA | -25°C ~ 85°C | - | - | Bidirectional | Chassis Mount | - |
|
HK100T09100 Amps rated Split core Hall e |
110 |
|
|
- | Module, Single Pass Through | Bulk | Active | AC/DC | Hall Effect | 100A | 1 | Analog Voltage | - | DC ~ 20kHz | ±1% | ±2% | ±15V | 3µs | 25mA | -25°C ~ 85°C | - | - | Bidirectional | Chassis Mount | - |
|
HSS500T01500 Amps rated open loop Hall ef |
157 |
|
|
- | Module, Single Pass Through | Bulk | Active | AC/DC | Hall Effect | 500A | 1 | Analog Voltage | - | DC ~ 25kHz | ±1% | ±1% | ±15V | 5µs | 15mA | -40°C ~ 105°C | - | - | Bidirectional | Chassis Mount | - |
|
HJ200T02200 Amps rated Split core Hall e |
120 |
|
|
- | Module, Single Pass Through | Bulk | Active | AC/DC | Hall Effect | 200A | 1 | Analog Voltage | - | DC ~ 20kHz | ±1% | ±2% | 5V | - | 18mA | -25°C ~ 85°C | - | - | Bidirectional | Chassis Mount | - |
|
HSS800T01800 Amps rated open loop Hall ef |
107 |
|
|
- | Module, Single Pass Through | Bulk | Active | AC/DC | Hall Effect | 800A | 1 | Analog Voltage | - | DC ~ 25kHz | ±1% | ±1% | ±15V | 5µs | 15mA | -40°C ~ 105°C | - | - | Bidirectional | Chassis Mount | - |
|
HJ050T0250 Amps rated Split core Hall ef |
102 |
|
|
- | Module, Single Pass Through | Bulk | Active | AC/DC | Hall Effect | 50A | 1 | Analog Voltage | - | DC ~ 20kHz | ±1% | ±2% | 5V | - | 18mA | -25°C ~ 85°C | - | - | Bidirectional | Chassis Mount | - |
|
HE300T04300 Amps rated closed loop Hall |
1,800 |
|
|
- | Module, Single Pass Through | Bulk | Active | AC/DC | Hall Effect | 300A | 1 | Current | 0.5mA/A | DC ~ 100kHz | ±0.1% | ±0.8% | ±12V ~ 15V | 1µs | - | -40°C ~ 85°C | - | - | Bidirectional | Chassis Mount | - |
|
HE200T04200 Amps rated closed loop Hall |
435 |
|
|
- | Module, Single Pass Through | Bulk | Active | AC/DC | Hall Effect | 200A | 1 | Current | 0.5mA/A | DC ~ 100kHz | ±0.1% | ±0.8% | ±12V ~ 15V | 1µs | - | -40°C ~ 85°C | - | - | Bidirectional | Chassis Mount | - |
Category Overview
Current Sensors Products & Selection Guide
Current Sensors are widely used in industrial automation, automotive electronics, communication equipment, consumer electronics, new energy systems, and many other electronic applications. We offer products from multiple manufacturers, packages, and specifications to help engineers and buyers compare and source suitable components.
Use the manufacturer, key specification, availability, and Datasheet filters to narrow down the right Current Sensors. If the exact part is not listed, submit an inquiry and our team can help check stock, lead time, and suitable alternatives.
FAQ
How do I choose the right Current Sensors?
Start with the required electrical specifications, package, operating temperature, application conditions, and manufacturer preference, then compare availability and lead time.
Can I order based on the stock shown on this page?
Inventory can change with supply conditions. For project or volume requirements, please submit an inquiry so current stock, pricing, and lead time can be confirmed.
What if the exact part number I need is not listed?
Send us the part number and required quantity. We can help source hard-to-find parts and suggest suitable alternatives based on key specifications.
Do you provide Datasheets and technical documents?
Yes. Use the Datasheet links in the product list to view available technical documents. If a document is unavailable, contact us and we can help check it.