Current Sensors
| Photo | Mfr. Part # | Availability | Quantity | Datasheet | Series | Package/Case | Packaging | Product Status | For Measuring | Sensor Type | Current - Sensing | Number of Channels | Output | Sensitivity | Frequency | Linearity | Accuracy | Voltage - Supply | Response Time | Current - Supply (Max) | Operating Temperature | Grade | Qualification | Polarization | Mounting Type | Supplier Device Package |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
MCQ1823GQTE-340UALAEC-ZAUTOMOTIVE-GRADE, LINEAR HALL-EF |
0 |
|
|
- | 12-PowerWFQFN | Tape & Reel (TR) | Active | AC/DC | Hall Effect | 40A | 1 | Analog Voltage | 33mV/A | 120kHz | ±0.5% | ±2.5% | 3V ~ 3.6V | 4µs | 12mA | -40°C ~ 125°C (TJ) | Automotive | AEC-Q101 | Unidirectional | Surface Mount, Wettable Flank | 12-TQFN (3x3) |
|
MCQ1823GQTE-520BRLAEC-PAUTOMOTIVE-GRADE, LINEAR HALL-EF |
0 |
|
|
- | 12-PowerWFQFN | Tape & Reel (TR) | Active | AC/DC | Hall Effect | 20A | 1 | Ratiometric, Voltage | 100mV/A | 120kHz | ±0.5% | ±2.5% | 4.5V ~ 5.5V | 4µs | 12mA | -40°C ~ 125°C (TJ) | Automotive | AEC-Q101 | Bidirectional | Surface Mount, Wettable Flank | 12-TQFN (3x3) |
|
MCS1823GQTE-505UAN-PULTRA-SMALL PACKAGE, LINEAR HALL |
0 |
|
|
- | 12-PowerWFQFN | Tape & Reel (TR) | Active | AC/DC | Hall Effect | 5A | 1 | Analog Voltage | 400mV/A | 120kHz | ±0.5% | ±2.5% | 4.5V ~ 5.5V | 4µs | 12mA | -40°C ~ 125°C (TJ) | Automotive | AEC-Q101 | Unidirectional | Surface Mount, Wettable Flank | 12-TQFN (3x3) |
|
MCQ1823GQTE-320UANAEC-ZAUTOMOTIVE-GRADE, LINEAR HALL-EF |
0 |
|
|
- | 12-PowerWFQFN | Tape & Reel (TR) | Active | AC/DC | Hall Effect | 20A | 1 | Analog Voltage | 66mV/A | 120kHz | ±0.5% | ±2.5% | 3V ~ 3.6V | 4µs | 12mA | -40°C ~ 125°C (TJ) | Automotive | AEC-Q101 | Unidirectional | Surface Mount, Wettable Flank | 12-TQFN (3x3) |
|
IT65-SCURRENT TRANSDUCER |
0 |
|
|
IT | Module, Single Pass Through | Bulk | Obsolete | AC/DC | Closed Loop | 60A | 1 | - | - | 800kHz | ±0.009% | - | ±14.25V ~ 15.75V | 1µs | 78mA | -40°C ~ 85°C | - | - | Unidirectional | Chassis Mount | - |
|
IT205-SCURRENT TRANSDUCER |
0 |
|
|
IT | Module, Single Pass Through | Bulk | Obsolete | AC/DC | Flux Gate, Closed Loop | 200A | 1 | - | - | 1MHz | ±0.0011% | - | ±14.25V ~ 15.75V | 1µs | 78mA | -40°C ~ 85°C | - | - | Unidirectional | Chassis Mount | - |
|
IT405SCURRENT TRANSDUCER |
0 |
|
|
IT | Module, Single Pass Through | Bulk | Obsolete | AC/DC | Closed Loop | 400A | 1 | - | - | 300kHz | ±0.0012% | - | ±14.25V ~ 15.75V | 1µs | 139mA | -40°C ~ 85°C | - | - | Unidirectional | Chassis Mount | - |
|
CTSR 0.3-P TSENSOR CURRENT |
0 |
|
|
CTSR | Module, Single Pass Through | Bulk | Obsolete | AC/DC | Closed Loop | 300mA | 1 | Voltage | - | 3.5kHz | ±0.5% | ±1.9% | 4.75V ~ 5.25V | 50µs | 21.6mA | -40°C ~ 105°C | - | - | Bidirectional | Through Hole | - |
|
CKSR 25-NP/SP3 TSENSOR CURRENT |
0 |
|
|
CKSR | Module | Bulk | Obsolete | AC/DC | Flux Gate, Closed Loop | 25A | 1 | Voltage | 25mV/A | DC ~ 300kHz | ±0.1% | - | 4.75V ~ 5.25V | 300ns | - | -40°C ~ 105°C | - | - | Bidirectional | Through Hole | - |
|
HLSR 10-P/SP3SENSOR CURRENT HALL |
0 |
|
|
HLSR-P/SP3 | Module | Bulk | Obsolete | AC/DC | Open Loop | 10A | 1 | Voltage | - | - | - | - | 5V | - | - | - | - | - | - | Through Hole | - |
|
HAX 1500-S/SP21SENSOR CURRENT HALL |
0 |
|
|
HAX | Module, Single Pass Through | Bulk | Obsolete | AC/DC | Hall Effect | 1500A | 1 | Voltage | - | DC ~ 25kHz | ±1% | ±1% | ±15V | - | - | -40°C ~ 85°C | - | - | Bidirectional | Chassis Mount | - |
|
CASR 6-NP/SP1SENSOR CURRENT FLUX |
0 |
|
|
CASR | Module | Bulk | Obsolete | AC/DC | Closed Loop | 6A | 1 | Voltage | - | DC ~ 300kHz | ±1% | - | 4.75V ~ 5.25V | - | - | -40°C ~ 105°C | - | - | Bidirectional | Through Hole | - |
|
HAZ 20000-SRUSENSOR CURRENT HALL |
0 |
|
|
HAZ | Module | Bulk | Obsolete | AC/DC | Hall Effect | 20000A | 1 | Voltage | - | DC, 15Hz ~ 3kHz | ±0.5% | ±1% | ±15V | - | 30mA | -25°C ~ 85°C | - | - | Bidirectional | Chassis Mount | - |
|
LA 35-NP/SP1SENSOR CURRENT HALL |
0 |
|
|
LA | Module | Bulk | Obsolete | AC/DC | Closed Loop | 35A | 1 | - | - | DC ~ 150kHz | ±0.2% | ±0.5% | ±15V | - | 10mA | -25°C ~ 70°C | - | - | Bidirectional | Through Hole | - |
|
HAZ 4000-SRUSENSOR CURRENT HALL |
0 |
|
|
HAZ | Module | Bulk | Obsolete | AC/DC | Hall Effect | 4000A | 1 | Voltage | - | DC, 15Hz ~ 3kHz | ±0.5% | ±1% | ±15V | - | 30mA | -25°C ~ 85°C | - | - | Bidirectional | Chassis Mount | - |
|
LF 505-S/SP35SENSOR CURRENT HALL |
0 |
|
|
LF | Module, Single Pass Through | Bulk | Obsolete | AC/DC | Closed Loop | 500A | 1 | - | - | DC ~ 100kHz | ±0.1% | ±0.6% | ±15V ~ 24V | 1µs | 24mA | -40°C ~ 70°C | - | - | Bidirectional | Chassis Mount | - |
|
PCM 10-P/SP2SENSOR CURRENT HALL |
0 |
|
|
- | - | Bulk | Obsolete | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
LF 2010-S/SPA7SENSOR CURRENT HALL |
0 |
|
|
LF | Module, Single Pass Through | Bulk | Obsolete | AC/DC | Closed Loop | 2000A | 1 | Current | - | DC ~ 150kHz | ±1% | ±0.3% | 14.25V ~ 25.2V | 500ns | - | -40°C ~ 85°C | - | - | Bidirectional | Chassis Mount | - |
|
HAH3DR 700-S00SENSOR CURRENT |
0 |
|
|
HAH3DR | Module | Bulk | Obsolete | AC/DC | Hall Effect, Open Loop | 700A | 1 | Ratiometric, Voltage | 2.86mV/A | DC ~ 40kHz | ±1% | - | 4.75V ~ 5.25V | 6µs | 50mA | -40°C ~ 125°C | - | - | Bidirectional | Through Hole | - |
|
LT 4000-S/SP11CURRENT TRANSDUCER |
0 |
|
|
- | - | Bulk | Obsolete | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
Category Overview
Current Sensors Products & Selection Guide
Current Sensors are widely used in industrial automation, automotive electronics, communication equipment, consumer electronics, new energy systems, and many other electronic applications. We offer products from multiple manufacturers, packages, and specifications to help engineers and buyers compare and source suitable components.
Use the manufacturer, key specification, availability, and Datasheet filters to narrow down the right Current Sensors. If the exact part is not listed, submit an inquiry and our team can help check stock, lead time, and suitable alternatives.
FAQ
How do I choose the right Current Sensors?
Start with the required electrical specifications, package, operating temperature, application conditions, and manufacturer preference, then compare availability and lead time.
Can I order based on the stock shown on this page?
Inventory can change with supply conditions. For project or volume requirements, please submit an inquiry so current stock, pricing, and lead time can be confirmed.
What if the exact part number I need is not listed?
Send us the part number and required quantity. We can help source hard-to-find parts and suggest suitable alternatives based on key specifications.
Do you provide Datasheets and technical documents?
Yes. Use the Datasheet links in the product list to view available technical documents. If a document is unavailable, contact us and we can help check it.