Current Sensors
| Photo | Mfr. Part # | Availability | Quantity | Datasheet | Series | Package/Case | Packaging | Product Status | For Measuring | Sensor Type | Current - Sensing | Number of Channels | Output | Sensitivity | Frequency | Linearity | Accuracy | Voltage - Supply | Response Time | Current - Supply (Max) | Operating Temperature | Grade | Qualification | Polarization | Mounting Type | Supplier Device Package |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
CTR05000SENSOR CURRENT XFMR 10A, 20, 50A |
0 |
|
|
CTR | Module, Single Pass Through | Bulk | Active | AC | Transformer w/Conditioning | 10A, 20, 50A (Selectable) | 1 | Ratiometric, 4mA ~ 20mA | - | 10Hz ~ 400Hz | - | ±0.8% | 24V | 600ms | 23mA | -20°C ~ 50°C | - | - | Bidirectional | Chassis Mount | - |
|
MNS2-9-IN-3P-150ALTA IND 3 PHASE CURRENT 150A |
0 |
|
|
- | IoT Finished Device | Bulk | Active | AC | Current Sensor | 150A | - | - | - | 50Hz ~ 100Hz | - | ±2% | 2V ~ 3.8V | - | 22.6mA | -40°C ~ 85°C | - | - | - | Chassis Mount | - |
|
ISOBLOCK I-ZF (500A 5V)ZERO FLUX CURRENT SENSOR |
0 |
|
|
IsoBlock I-ZF | Module | Box | Active | DC | Current Transducer | 500A | 1 | Open Collector | - | 80kHz | ±0.02% | ±0.1% | 24VDC | 1µs | - | -25°C ~ 70°C | - | - | Unidirectional | DIN Rail | - |
|
ISOBLOCK I-ZF (500AAC 7VAC )ZERO FLUX CURRENT SENSOR |
0 |
|
|
IsoBlock I-ZF | Module | Box | Active | DC | Current Transducer | 500A | 1 | Ratiometric, Voltage | - | 80kHz | ±0.02% | ±0.1% | 24VDC | 1µs | - | -25°C ~ 70°C | - | - | Unidirectional | DIN Rail | - |
|
ISOBLOCK I-ZF (500A 10V)VOLTAGE TRANSDUCER W/ISOLATION |
0 |
|
|
IsoBlock I-ZF | Module | Box | Active | DC | Current Transducer | 500A | 1 | Open Collector | - | 80kHz | ±0.02% | ±0.1% | 24VDC | 1µs | - | -25°C ~ 70°C | - | - | Unidirectional | DIN Rail | - |
|
DV 2000/SP1TRANSDUCER |
0 |
|
|
- | - | Bulk | Active | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
CR4180-10SENSOR CURRENT XFMR 10A AC |
0 |
|
|
CR4100 | Module, Triple Pass Through | Bulk | Active | AC | Transformer w/Conditioning | 10A | 3 | Ratiometric, 4mA ~ 20mA | - | 20Hz ~ 5kHz | - | ±0.5% | 24V | 250ms | 110mA | 0°C ~ 60°C | - | - | Bidirectional | DIN Rail, Panel | - |
|
CR4180-20SENSOR CURRENT XFMR 20A AC |
0 |
|
|
CR4100 | Module, Triple Pass Through | Bulk | Active | AC | Transformer w/Conditioning | 20A | 3 | Ratiometric, 4mA ~ 20mA | - | 20Hz ~ 5kHz | - | ±0.5% | 24V | 250ms | 110mA | 0°C ~ 60°C | - | - | Bidirectional | DIN Rail, Panel | - |
|
CR4180-5SENSOR CURRENT XFMR 5A AC |
0 |
|
|
CR4100 | Module, Triple Pass Through | Bulk | Active | AC | Transformer w/Conditioning | 5A | 3 | Ratiometric, 4mA ~ 20mA | - | 20Hz ~ 5kHz | - | ±0.5% | 24V | 250ms | 110mA | 0°C ~ 60°C | - | - | Bidirectional | DIN Rail, Panel | - |
|
CR4180-30SENSOR CURRENT XFMR 30A AC |
0 |
|
|
CR4100 | Module, Triple Pass Through | Bulk | Active | AC | Transformer w/Conditioning | 30A | 3 | Ratiometric, 4mA ~ 20mA | - | 20Hz ~ 5kHz | - | ±0.5% | 24V | 250ms | 110mA | 0°C ~ 60°C | - | - | Bidirectional | DIN Rail, Panel | - |
|
CR4180-25SENSOR CURRENT XFMR 25A AC |
0 |
|
|
CR4100 | Module, Triple Pass Through | Bulk | Active | AC | Transformer w/Conditioning | 25A | 3 | Ratiometric, 4mA ~ 20mA | - | 20Hz ~ 5kHz | - | ±0.5% | 24V | 250ms | 110mA | 0°C ~ 60°C | - | - | Bidirectional | DIN Rail, Panel | - |
|
CR4180-15SENSOR CURRENT XFMR 15A AC |
0 |
|
|
CR4100 | Module, Triple Pass Through | Bulk | Active | AC | Transformer w/Conditioning | 15A | 3 | Ratiometric, 4mA ~ 20mA | - | 20Hz ~ 5kHz | - | ±0.5% | 24V | 250ms | 110mA | 0°C ~ 60°C | - | - | Bidirectional | DIN Rail, Panel | - |
|
CPCO-4000-77-BP10DC-AC CURRENT PROBE, CLAMP-ON, 4 |
1 |
|
|
CPCO | Box | Box | Active | AC/DC | Open Loop | 4000A | 1 | Ratiometric, ±10V | - | DC ~ 40kHz | ±0.5% | 1% | 11V ~ 31V | 10µs | 47mA | -40°C ~ 100°C | - | - | Bidirectional | Panel Mount | - |
|
LF 2005-S/SP11TRANSDUCER |
0 |
|
|
LF | Module, Single Pass Through | Bulk | Not For New Designs | AC/DC | Hall Effect, Closed Loop | 2000A | 1 | Current | - | DC ~ 100kHz | ±0.1% | ±0.4% | ±15V ~ 24V | 1µs | - | -40°C ~ 85°C | - | - | Bidirectional | Chassis Mount | - |
|
LF 2005-S/SP24TRANSDUCER |
0 |
|
|
LF | Module, Single Pass Through | Bulk | Not For New Designs | AC/DC | Hall Effect, Closed Loop | 2000A | 1 | Current | - | DC ~ 100kHz | ±0.1% | ±0.3% | ±15V ~ 24V | 1µs | - | -40°C ~ 85°C | - | - | Bidirectional | Chassis Mount | - |
|
LF 2005-S/SP13TRANSDUCER |
0 |
|
|
LF | Module, Single Pass Through | Bulk | Not For New Designs | AC/DC | Hall Effect, Closed Loop | 2000A | 1 | Current | - | DC ~ 150kHz | ±0.1% | ±0.3% | ±15V ~ 24V | 1µs | - | -40°C ~ 80°C | - | - | Bidirectional | Chassis Mount | - |
|
LF 2005-S/SP20TRANSDUCER |
0 |
|
|
LF | Module, Single Pass Through | Bulk | Not For New Designs | AC/DC | Hall Effect, Closed Loop | 2000A | 1 | Current | - | DC ~ 100kHz | ±0.1% | ±0.3% | ±15V ~ 24V | 1µs | - | -40°C ~ 85°C | - | - | Bidirectional | Chassis Mount | - |
|
LF 2005-S/SP36TRANSDUCER |
0 |
|
|
LF | Module, Single Pass Through | Bulk | Not For New Designs | AC/DC | Hall Effect, Closed Loop | 2000A | 1 | Current | - | DC ~ 100kHz | ±0.1% | ±0.3% | ±15V ~ 24V | 1µs | - | -40°C ~ 85°C | - | - | Bidirectional | Chassis Mount | - |
|
LT 2005-S/SP15TRANSDUCER |
0 |
|
|
LT | Module, Single Pass Through | Bulk | Not For New Designs | AC/DC | Hall Effect, Closed Loop | 2000A | 1 | Current | - | DC ~ 100kHz | ±0.1% | ±0.3% | ±24V | 1µs | - | -25°C ~ 70°C | - | - | Bidirectional | Chassis Mount | - |
|
CRD4170-1SENSOR CURRENT XFMR 1A AC |
0 |
|
|
CRD4100 | Module | Bulk | Active | AC | Transformer w/Conditioning | 1A | 3 | RS485 | - | 20Hz ~ 5kHz | - | ±0.5% | 24V | 250ms | 30mA | 0°C ~ 60°C | - | - | Bidirectional | DIN Rail, Panel | - |
Category Overview
Current Sensors Products & Selection Guide
Current Sensors are widely used in industrial automation, automotive electronics, communication equipment, consumer electronics, new energy systems, and many other electronic applications. We offer products from multiple manufacturers, packages, and specifications to help engineers and buyers compare and source suitable components.
Use the manufacturer, key specification, availability, and Datasheet filters to narrow down the right Current Sensors. If the exact part is not listed, submit an inquiry and our team can help check stock, lead time, and suitable alternatives.
FAQ
How do I choose the right Current Sensors?
Start with the required electrical specifications, package, operating temperature, application conditions, and manufacturer preference, then compare availability and lead time.
Can I order based on the stock shown on this page?
Inventory can change with supply conditions. For project or volume requirements, please submit an inquiry so current stock, pricing, and lead time can be confirmed.
What if the exact part number I need is not listed?
Send us the part number and required quantity. We can help source hard-to-find parts and suggest suitable alternatives based on key specifications.
Do you provide Datasheets and technical documents?
Yes. Use the Datasheet links in the product list to view available technical documents. If a document is unavailable, contact us and we can help check it.