Current Sensors
| Photo | Mfr. Part # | Availability | Quantity | Datasheet | Series | Package/Case | Packaging | Product Status | For Measuring | Sensor Type | Current - Sensing | Number of Channels | Output | Sensitivity | Frequency | Linearity | Accuracy | Voltage - Supply | Response Time | Current - Supply (Max) | Operating Temperature | Grade | Qualification | Polarization | Mounting Type | Supplier Device Package |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
|
CSLA1CDSENSOR CURRENT HALL 57A AC/DC |
0 |
|
|
CSLA | Module, Single Pass Through | Bulk | Obsolete | AC/DC | Hall Effect, Open Loop | 57A | 1 | Ratiometric, Voltage | 49.6mV/N | - | - | - | 8V ~ 16V | 3µs | 19mA | -25°C ~ 85°C | - | - | Bidirectional | Through Hole | - |
|
L40S600D15MCURRENT SENSOR (600A; 15V) -40 1 |
0 |
|
|
L40S D15 | Module | Tray | Active | AC/DC | Hall Effect, Open Loop | 600A | 1 | Ratiometric, Voltage | - | DC ~ 25kHz | ±0.1% | - | ±12V ~ 15V | 5µs | 25mA | -40°C ~ 105°C | - | - | Bidirectional | Chassis Mount | - |
|
L40S600D15JCURRENT SENSOR (600A; 15V) -40 1 |
0 |
|
|
L40S D15 | Module | Tray | Active | AC/DC | Hall Effect, Open Loop | 600A | 1 | Ratiometric, Voltage | - | DC ~ 25kHz | ±0.1% | - | ±12V ~ 15V | 5µs | 25mA | -40°C ~ 105°C | - | - | Bidirectional | Chassis Mount | - |
|
HAM 250-S04TRANSDUCER |
0 |
|
|
HAM | Module | Bulk | Active | AC/DC | Hall Effect, Open Loop | 250A | 1 | Voltage | 8mV/A | - | ±0.1% | - | 4.75V ~ 5.25V | 2µs | 20mA | -40°C ~ 125°C | - | - | Unidirectional | Chassis Mount | - |
|
CTSR 0.3-TP/SP14TRANSDUCER |
0 |
|
|
CTSR | Module | Bulk | Active | AC/DC | Closed Loop | 300mA | 1 | Voltage | 4V/A | DC ~ 3.5kHz | ±0.5% | - | 4.75V ~ 5.25V | 50µs | 21.6mA | -40°C ~ 105°C | - | - | Unidirectional | Through Hole | - |
|
CSDC1BASENSOR CURRENT SWITCH 1A AC/DC |
0 |
|
|
CSDA | Module, Single Pass Through | Bulk | Obsolete | AC/DC | Current Switch | 1A | 1 | NPN | - | - | - | - | 5V | 100µs | 12mA | -25°C ~ 85°C | - | - | Bidirectional | Through Hole | - |
|
LA 125-P/SP1SENSORS |
0 |
|
|
LA | Module, Single Pass Through | Bulk | Active | AC/DC | Hall Effect, Closed Loop | 125A | 1 | Current | - | DC ~ 100kHz | ±0.15% | ±0.8% | ±12V ~ 15V | 1µs | - | -25°C ~ 85°C | - | - | Bidirectional | Through Hole | - |
|
LA 125-PSENSORS |
0 |
|
|
LA | Module, Single Pass Through | Bulk | Active | AC/DC | Hall Effect, Closed Loop | 125A | 1 | - | - | DC ~ 100kHz | ±0.15% | ±0.8% | 12V ~ 15V | 1µs | 16mA | -40°C ~ 85°C | - | - | Bidirectional | Through Hole | - |
|
LA 125-P/SP3SENSORS |
0 |
|
|
LA | Module, Single Pass Through | Bulk | Active | AC/DC | Hall Effect, Closed Loop | 125A | 1 | Current | - | DC ~ 100kHz | ±0.15% | ±0.8% | ±12V ~ 15V | 1µs | - | -25°C ~ 85°C | - | - | Bidirectional | Through Hole | - |
|
L40S800D15MCURRENT SENSOR (800A; 15V) -40 1 |
0 |
|
|
L40S D15 | Module | Tray | Active | AC/DC | Hall Effect, Open Loop | 800A | 1 | Ratiometric, Voltage | - | DC ~ 25kHz | ±0.1% | - | ±12V ~ 15V | 5µs | 25mA | -40°C ~ 105°C | - | - | Bidirectional | Chassis Mount | - |
|
L40S800D15JCURRENT SENSOR (800A; 15V) -40 1 |
0 |
|
|
L40S D15 | Module | Tray | Active | AC/DC | Hall Effect, Open Loop | 800A | 1 | Ratiometric, Voltage | - | DC ~ 25kHz | ±0.1% | - | ±12V ~ 15V | 5µs | 25mA | -40°C ~ 105°C | - | - | Bidirectional | Chassis Mount | - |
|
L40S200D15CMCURRENT SENSOR (200A; 15V) -40 1 |
0 |
|
|
L40S D15 | Module | Tray | Active | AC/DC | Hall Effect, Open Loop | 200A | 1 | Ratiometric, Voltage | - | DC ~ 25kHz | ±0.1% | - | ±12V ~ 15V | 5µs | 25mA | -40°C ~ 105°C | - | - | Bidirectional | Chassis Mount | - |
|
L40S200D15CJCURRENT SENSOR (200A; 15V) -40 1 |
0 |
|
|
L40S D15 | Module | Tray | Active | AC/DC | Hall Effect, Open Loop | 200A | 1 | Ratiometric, Voltage | - | DC ~ 25kHz | ±0.1% | - | ±12V ~ 15V | 5µs | 25mA | -40°C ~ 105°C | - | - | Bidirectional | Chassis Mount | - |
|
CTSR 1-TP/SP15TRANSDUCER |
0 |
|
|
CTSR | Module | Bulk | Active | AC/DC | Closed Loop | 1A | 1 | Voltage | 1.2V/A | DC ~ 9.5kHz | ±0.5% | - | 4.75V ~ 5.25V | 50µs | 21.6mA | -40°C ~ 105°C | - | - | - | Through Hole | - |
|
CTSR 0.3-TP/SP15TRANSDUCER |
0 |
|
|
- | - | Bulk | Active | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
LA 25-NP/SP32SENSORS |
0 |
|
|
- | - | Bulk | Not For New Designs | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
CSNA111-009SENSOR CURRENT HALL 70A AC/DC |
0 |
|
|
CSN | Module, Single Pass Through | Bulk | Obsolete | AC/DC | Hall Effect, Closed Loop | 70A | 1 | Ratiometric, Voltage | - | DC ~ 150kHz | ±1% | ±0.5% | ±15V | 1µs | 10mA | 0°C ~ 70°C | - | - | Bidirectional | Through Hole | - |
|
L40S400D15CMCURRENT SENSOR (400A; 15V) -40 1 |
0 |
|
|
L40S D15 | Module | Tray | Active | AC/DC | Hall Effect, Open Loop | 400A | 1 | Ratiometric, Voltage | - | DC ~ 25kHz | ±0.1% | - | ±12V ~ 15V | 5µs | 25mA | -40°C ~ 105°C | - | - | Bidirectional | Chassis Mount | - |
|
L40S400D15CJCURRENT SENSOR (400A; 15V) -40 1 |
0 |
|
|
L40S D15 | Module | Tray | Active | AC/DC | Hall Effect, Open Loop | 400A | 1 | Ratiometric, Voltage | - | DC ~ 25kHz | ±0.1% | - | ±12V ~ 15V | 5µs | 25mA | -40°C ~ 105°C | - | - | Bidirectional | Chassis Mount | - |
|
L40S1T2D15MCURRENT SENSOR (1200A; 15V) -40 |
0 |
|
|
L40S D15 | Module | Tray | Active | AC/DC | Hall Effect, Open Loop | 1200A | 1 | Ratiometric, Voltage | - | DC ~ 25kHz | ±0.1% | - | ±12V ~ 15V | 5µs | 25mA | -40°C ~ 105°C | - | - | Bidirectional | Chassis Mount | - |
Category Overview
Current Sensors Products & Selection Guide
Current Sensors are widely used in industrial automation, automotive electronics, communication equipment, consumer electronics, new energy systems, and many other electronic applications. We offer products from multiple manufacturers, packages, and specifications to help engineers and buyers compare and source suitable components.
Use the manufacturer, key specification, availability, and Datasheet filters to narrow down the right Current Sensors. If the exact part is not listed, submit an inquiry and our team can help check stock, lead time, and suitable alternatives.
FAQ
How do I choose the right Current Sensors?
Start with the required electrical specifications, package, operating temperature, application conditions, and manufacturer preference, then compare availability and lead time.
Can I order based on the stock shown on this page?
Inventory can change with supply conditions. For project or volume requirements, please submit an inquiry so current stock, pricing, and lead time can be confirmed.
What if the exact part number I need is not listed?
Send us the part number and required quantity. We can help source hard-to-find parts and suggest suitable alternatives based on key specifications.
Do you provide Datasheets and technical documents?
Yes. Use the Datasheet links in the product list to view available technical documents. If a document is unavailable, contact us and we can help check it.