Current Sensors

Manufacturers Series Package/Case Packaging Product Status For Measuring Sensor Type Current - Sensing Number of Channels Output Sensitivity Frequency Linearity Accuracy Voltage - Supply Response Time Current - Supply (Max) Operating Temperature Grade Qualification Polarization Mounting Type Supplier Device Package

Reset All
Apply All
Result
Photo Mfr. Part # Availability Price Quantity Datasheet Series Package/Case Packaging Product Status For Measuring Sensor Type Current - Sensing Number of Channels Output Sensitivity Frequency Linearity Accuracy Voltage - Supply Response Time Current - Supply (Max) Operating Temperature Grade Qualification Polarization Mounting Type Supplier Device Package
HO 80-NPW-0100

HO 80-NPW-0100

SENSORS

LEM USA Inc.

0
RFQ
HO 80-NPW-0100Datasheet HO Module Bulk Active AC/DC Open Loop 80A 1 Voltage - - ±0.5% - 4.5V ~ 5.5V - 31mA -40°C ~ 105°C - - Bidirectional Through Hole -
HO 120-NP/SP33-1106

HO 120-NP/SP33-1106

SENSORS

LEM USA Inc.

0
RFQ
HO 120-NP/SP33-1106Datasheet HO Module Bulk Active AC/DC Hall Effect, Open Loop 120A 1 Voltage 3.83mV/A 350kHz ±0.5% ±1.25% 3.14V ~ 3.46V 2.5µs 25mA -40°C ~ 105°C - - Unidirectional Through Hole -
HX 50-P/SP14

HX 50-P/SP14

SENSORS

LEM USA Inc.

0
RFQ
HX 50-P/SP14Datasheet HX Module Bulk Not For New Designs AC/DC Hall Effect 50A 1 Analog Voltage - DC ~ 50kHz ±1% ±1% ±15V 3µs 15mA -40°C ~ 85°C - - Unidirectional Through Hole -
LA37S300S05KJ

LA37S300S05KJ

CURRENT SENSOR (300A; 5V) -40 10

Tamura

0
RFQ
LA37S300S05KJDatasheet LA37S S05K Module, Single Pass Through Tray Active DC Open Loop 300A 1 Analog Voltage 2.083mV/A 100kHz ±0.5% ±1.8% 4.5V ~ 5.5V 4µs 23mA -40°C ~ 105°C - - - Chassis Mount -
LA37S100S05KJ

LA37S100S05KJ

CURRENT SENSOR (100A; 5V) -40 10

Tamura

0
RFQ
LA37S100S05KJDatasheet LA37S S05K Module, Single Pass Through Tray Active DC Open Loop 100A 1 Analog Voltage 6.25mV/A 100kHz ±0.5% ±1.8% 4.5V ~ 5.5V 4µs 23mA -40°C ~ 105°C - - - Chassis Mount -
LA37S500S05KJ

LA37S500S05KJ

CURRENT SENSOR (500A; 5V) -40 10

Tamura

0
RFQ
LA37S500S05KJDatasheet LA37S S05K Module, Single Pass Through Tray Active DC Open Loop 500A 1 Analog Voltage 1.25mV/A 100kHz ±0.5% ±1.8% 4.5V ~ 5.5V 4µs 23mA -40°C ~ 105°C - - - Chassis Mount -
LA37S400S05KJ

LA37S400S05KJ

CURRENT SENSOR (400A; 5V) -40 10

Tamura

0
RFQ
LA37S400S05KJDatasheet LA37S S05K Module, Single Pass Through Tray Active DC Open Loop 400A 1 Analog Voltage 1.563mV/A 100kHz ±0.5% ±1.8% 4.5V ~ 5.5V 4µs 23mA -40°C ~ 105°C - - - Chassis Mount -
LA37S200S05KJ

LA37S200S05KJ

CURRENT SENSOR (200A; 5V) -40 10

Tamura

0
RFQ
LA37S200S05KJDatasheet LA37S S05K Module, Single Pass Through Tray Active DC Open Loop 200A 1 Analog Voltage 3.125mV/A 100kHz ±0.5% ±1.8% 4.5V ~ 5.5V 4µs 23mA -40°C ~ 105°C - - - Chassis Mount -
LA37S050S05KJ

LA37S050S05KJ

CURRENT SENSOR (50A; 5V) -40 105

Tamura

0
RFQ
LA37S050S05KJDatasheet LA37S S05K Module, Single Pass Through Tray Active DC Open Loop 50A 1 Analog Voltage 12.5mV/A 100kHz ±0.5% ±1.8% 4.5V ~ 5.5V 4µs 23mA -40°C ~ 105°C - - - Chassis Mount -
LA37S600S05KJ

LA37S600S05KJ

CURRENT SENSOR (600A; 5V) -40 10

Tamura

0
RFQ
LA37S600S05KJDatasheet LA37S S05K Module, Single Pass Through Tray Active DC Open Loop 600A 1 Analog Voltage 1.042mV/A 100kHz ±0.5% ±1.8% 4.5V ~ 5.5V 4µs 23mA -40°C ~ 105°C - - - Chassis Mount -
HX 12.5-P/SP31

HX 12.5-P/SP31

SENSORS

LEM USA Inc.

0
RFQ
HX 12.5-P/SP31Datasheet HX Module Bulk Not For New Designs AC/DC Hall Effect, Open Loop 12.5A 1 Analog Voltage - DC ~ 50kHz ±1% ±1.5% ±15V 5µs 20mA -25°C ~ 85°C - - Bidirectional Through Hole -
HX 10-P/SP31

HX 10-P/SP31

SENSORS

LEM USA Inc.

0
RFQ
HX 10-P/SP31Datasheet HX Module Bulk Not For New Designs AC/DC Hall Effect, Open Loop 10A 1 Analog Voltage - DC ~ 50kHz ±1% ±1.5% ±15V 5µs 20mA -25°C ~ 85°C - - Bidirectional Through Hole -
HAFS 200-S/SP8

HAFS 200-S/SP8

TRANSDUCER

LEM USA Inc.

0
RFQ
HAFS 200-S/SP8Datasheet - - Bulk Not For New Designs - - - - - - - - - - - - - - - - - -
HX 05-P/SP31

HX 05-P/SP31

SENSORS

LEM USA Inc.

0
RFQ
HX 05-P/SP31Datasheet HX Module Bulk Not For New Designs AC/DC Hall Effect, Open Loop 5A 1 Analog Voltage - DC ~ 50kHz ±1% ±1.5% ±15V 5µs 20mA -25°C ~ 85°C - - Bidirectional Through Hole -
HX 15-NP

HX 15-NP

SENSORS

LEM USA Inc.

0
RFQ
HX 15-NPDatasheet HX Module Bulk Not For New Designs AC/DC Hall Effect, Open Loop 15A, 30A (Selectable) 1 Analog Voltage - DC ~ 50kHz ±0.1% ±1% ±15V 3µs 15mA -25°C ~ 85°C - - Bidirectional Through Hole -
TL100-D1C

TL100-D1C

CURRENT SENSOR 100A 1 CHANNEL HA

Mornsun America, LLC

5
RFQ
TL100-D1CDatasheet TLx00-D1C Module, Single Pass Through Tray Not For New Designs AC/DC Hall Effect, Closed Loop 100A 1 Ratiometric, Current - 0Hz ~ 100kHz ±0.1% ±0.5% ±12V ~ 15V 1µs 25mA -40°C ~ 85°C - - Bidirectional Chassis Mount -
T60404N4647X261

T60404N4647X261

CURRENT SENSOR 100A, PRI OPEN, 5

VACUUMSCHMELZE

0
RFQ
T60404N4647X261Datasheet - 8-DIP Module Box Active AC/DC Closed Loop 100A 1 Ratiometric, Voltage - DC ~ 100kHz ±0.1% ±0.7% 4.75V ~ 5.25V 1µs 15mA -40°C ~ 85°C - - Unidirectional Through Hole -
HO 250-P/SP606-1106

HO 250-P/SP606-1106

SENSORS

LEM USA Inc.

0
RFQ
HO 250-P/SP606-1106Datasheet - - Bulk Active - - - - - - - - - - - - - - - - - -
HX 06-P/SP31

HX 06-P/SP31

SENSORS

LEM USA Inc.

0
RFQ
HX 06-P/SP31Datasheet HX Module Bulk Not For New Designs AC/DC Hall Effect, Open Loop 6A 1 Analog Voltage - DC ~ 50kHz ±1% ±1.5% ±15V 5µs 20mA -25°C ~ 85°C - - Bidirectional Through Hole -
HAB 60-S/SP5

HAB 60-S/SP5

CURRENT TRANSDUCER +/- 60A

LEM USA Inc.

0
RFQ
HAB 60-S/SP5Datasheet * - Bulk Active - - - - - - - - - - - - - - - - - -
Total 5184 Record«Prev1... 149150151152153154155156...260Next»

Category Overview

Current Sensors Products & Selection Guide

Current Sensors are widely used in industrial automation, automotive electronics, communication equipment, consumer electronics, new energy systems, and many other electronic applications. We offer products from multiple manufacturers, packages, and specifications to help engineers and buyers compare and source suitable components.

Use the manufacturer, key specification, availability, and Datasheet filters to narrow down the right Current Sensors. If the exact part is not listed, submit an inquiry and our team can help check stock, lead time, and suitable alternatives.

FAQ

How do I choose the right Current Sensors?

Start with the required electrical specifications, package, operating temperature, application conditions, and manufacturer preference, then compare availability and lead time.

Can I order based on the stock shown on this page?

Inventory can change with supply conditions. For project or volume requirements, please submit an inquiry so current stock, pricing, and lead time can be confirmed.

What if the exact part number I need is not listed?

Send us the part number and required quantity. We can help source hard-to-find parts and suggest suitable alternatives based on key specifications.

Do you provide Datasheets and technical documents?

Yes. Use the Datasheet links in the product list to view available technical documents. If a document is unavailable, contact us and we can help check it.

Masstock Electronics

Search

Masstock Electronics

Products

Masstock Electronics

Phone

Masstock Electronics

User

Masstock Electronics Masstock Electronics Masstock Electronics
WHATSAPP

+86 13760362468